A gradient optimization toolbox for general purpose time‐optimal MRI gradient waveform design
Authors:
Open Access
- 7 July 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (6) , 3234-3245
Abstract
Purpose: To introduce and demonstrate a software library for time‐optimal gradient waveform optimization with a wide range of applications. The software enables direct on‐the‐fly gradient waveform design on the scanner hardware for multiple vendors.Methods: The open‐source gradient optimization (GrOpt) toolbox was implemented in C with both Matlab and Python wrappers. The toolbox enables gradient waveforms to be generated based on a set of constraints that define the features and encodings for a given acquisition. The GrOpt optimization routine is based on the alternating direction method of multipliers (ADMM). Additional constraints enable error corrections to be added, or patient comfort and safety to be adressed. A range of applications and compute speed metrics are analyzed. Finally, the method is implemented and tested on scanners from different vendors.Results: Time‐optimal gradient waveforms for different pulse sequences and the constraints that define them are shown. Additionally, the ability to add, arbitrary motion (gradient moment) compensation or limit peripheral nerve stimulation is demonstrated. There exists a trade‐off between computation time and gradient raster time, but it was observed that acceptable gradient waveforms could be generated in 1‐40 ms. Gradient waveforms generated and run on the different scanners were functionally equivalent, and the images were comparable.Conclusions: GrOpt is an open source toolbox that enables on‐the‐fly optimization of gradient waveform design, subject to a set of defined constraints. GrOpt was presented for a range of imaging applications, analyzed in terms of computational complexity, and implemented to run on the scanner for a multi‐vendor demonstration.Keywords
This publication has 22 references indexed in Scilit:
- Time‐optimized 4D phase contrast MRI with real‐time convex optimization of gradient waveforms and fast excitation methodsMagnetic Resonance in Medicine, 2019
- Eddy current–nulled convex optimized diffusion encoding (EN‐CODE) for distortion‐free diffusion tensor imaging with short echo timesMagnetic Resonance in Medicine, 2017
- Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion–compensated diffusion‐weighted MRIMagnetic Resonance in Medicine, 2016
- Constrained optimization of gradient waveforms for generalized diffusion encodingJournal of Magnetic Resonance, 2015
- Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRIMagnetic Resonance in Medicine, 2013
- Efficient implementation of hardware‐optimized gradient sequences for real‐time imagingMagnetic Resonance in Medicine, 2010
- Time‐optimal multidimensional gradient waveform design for rapid imagingMagnetic Resonance in Medicine, 2003
- Minimizing dead-periods in flow-encoded or -compensated pulse sequences while imaging in oblique planesJournal of Magnetic Resonance Imaging, 1999
- Minimization of dead‐periods in MRI pulse sequences for imaging oblique planesMagnetic Resonance in Medicine, 1994
- MRI gradient waveform design by numerical optimizationMagnetic Resonance in Medicine, 1993