Flow‐volume loops measured with electrical impedance tomography in pediatric patients with asthma
- 6 February 2018
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 53 (5) , 636-644
Abstract
Background: Electrical impedance tomography (EIT) provides information on global and regional ventilation during tidal breathing and mechanical ventilation. During forced expiration maneuvers, the linearity of EIT and spirometric data has been documented in healthy persons. The present study investigates the potential diagnostic use of EIT in pediatric patients with asthma.Methods: EIT and spirometry were performed in 58 children with asthma (average age ± SD: 11.86 ± 3.13 years), and 58 healthy controls (average age ± SD: 12.12 ± 2.9 years). The correlation between EIT data and simultaneously acquired spirometric data were tested for FEV1, FEV0.5, MEF75, MEF50, and MEF25. Binary classification tests were performed for the EIT‐derived Tiffeneau index FEV1/FVC and the bronchodilator test index ΔFEV1. Average flow‐volume (FV) loops were generated for patients with pathologic spirometry to demonstrate the feasibility of EIT for graphic diagnosis of asthma.Results: Spirometry and global EIT‐based FV loops showed a strong correlation (P < 0.001, r > 0.9 in FEV1 and FEV0.5). In all criteria, the binary classification tests yielded high specificity (>93%), a high positive predictive value (≥75%) and a high negative predictive value (>80%), while sensitivity was higher in ΔFEV1 (86.67%) and lower in FEV1/FVC (25% and 35.29%). A typical concave shape of the EIT‐derived average FV loops was observed for asthmatic children with improvement after bronchospasmolysis.Conclusions: Global FV loops derived from EIT correlate well with spirometry. Positive bronchospasmolysis can be observed in EIT‐derived FV loops. Flow‐volume loops originated from EIT have a potential to visualize pulmonary function.Keywords
This publication has 19 references indexed in Scilit:
- Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthmaPhysiological Measurement, 2016
- Global and regional lung function in cystic fibrosis measured by electrical impedance tomographyPediatric Pulmonology, 2016
- Positioning of electrode plane systematically influences EIT imaging*Physiological Measurement, 2015
- Pulmonary function testing in children and infantsPhysiological Measurement, 2014
- Regional airway obstruction in cystic fibrosis determined by electrical impedance tomography in comparison with high resolution CTPhysiological Measurement, 2013
- Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?Intensive Care Medicine, 2012
- Regional ventilation in cystic fibrosis measured by electrical impedance tomographyJournal of Cystic Fibrosis, 2012
- Electrical Impedance Tomography's Correlation to Lung Volume is Not Influenced by Anthropometric ParametersJournal of Clinical Monitoring and Computing, 2006
- EIT images of ventilation: what contributes to the resistivity changes?Physiological Measurement, 2005
- Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activitiesPhysiological Measurement, 2000