Abstract
A building that looks strong enough might possibly collapse due to the earthquake load. Earthquake resistant design is generally based on an analysis of elastic structures that are given a load factor to simulate ultimate conditions. When an earthquake occurs, the collapse behavior of a building structure is inelastic. Evaluations that can estimate the inelastic condition of buildings during an earthquake are analyzed using pushover analysis. Pushover analysis is the nonlinear static load of the structural collapse behavior of an earthquake, while the performance point is the magnitude of the maximum displacement of the structure during a earthquake. The inelastic structure analysis and evaluation method used computer application SAP 2000. Evaluation results of structural performance levels according to Applied Technology Council 40 (ATC-40) on the X and Y direction structure, the maximum total drift and total inelastic drift maximum values in the X and Y directions included in the Immediate Occupancy (IO) level category (maximum drift value of a building structure 0.00047 < 0.005).

This publication has 1 reference indexed in Scilit: