Irpan Hidayat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Irpan Hidayat has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Made Suangga
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, Indonesia 11480
5 shared publications- Made Suangga
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta 11480, Indonesia
4 shared publications - Riza Suwondo
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, Indonesia
3 shared publications - Roesdiman Soegiarso
Universitas Tarumanagara, West Jakarta, DKI Jakarata
2 shared publications Adelia Dwidarma Nataadmadja
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University Jakarta, Indonesia 11480
1 shared publicationAgung Wirabuana
Civil Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, Indonesia 11480
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1564 (1)
Performance Assessment of Outrigger Systems in High-Rise Building Structures
In line with the advancement of high-rise building design, the integration of outrigger and core wall systems has become an effective approach to control excessive lateral displacement and improve overall structural performance. In this study, numerical modeling was conducted using seven different layouts of outrigger placement to identify the most effective configuration. The objectives of this research are to evaluate the structural period, base shear force, lateral displacement, and storey drift. The analysis employed both linear static and linear dynamic methods, with the dynamic analysis carried out using the response spectrum procedure in finite element software, in accordance with the requirements of SNI 1726-2019. The results indicate that buildings equipped with outrigger systems exhibit higher base shear force values compared to structures without outriggers, which helps ensure compliance with seismic design criteria. Conversely, the inclusion of outriggers significantly reduces the structural period, lateral displacement, and storey drift, demonstrating improved stiffness and deformation control. From a performance assessment perspective, particularly considering serviceability limit state criteria, the incorporation of outriggers effectively maintains inter-storey drift within acceptable limits, enhancing both safety and occupant comfort. The study concludes that the optimal configuration for a single outrigger installation is the existing location at Level 42, while for dual outriggers, the most effective arrangement combines the existing outrigger with an additional outrigger at Level 22. This configuration achieved the greatest improvement in reducing displacement and storey drift, confirming its suitability for enhancing the overall seismic performance of the high-rise structure. Moreover, by improving structural efficiency and resilience, the findings of this research contribute to the development of safer and more sustainable infrastructure that optimizes material use and extends the service life of tall buildings.
- 1 December 2025
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1564 (1)
Open AccessPerformance Assessment of Outrigger Systems in High-Rise Building Structures
In line with the advancement of high-rise building design, the integration of outrigger and core wall systems has become an effective approach to control excessive lateral displacement and improve overall structural performance. In this study, numerical modeling was conducted using seven different layouts of outrigger placement to identify the most effective configuration. The objectives of this research are to evaluate the structural period, base shear force, lateral displacement, and storey drift. The analysis employed both linear static and linear dynamic methods, with the dynamic analysis carried out using the response spectrum procedure in finite element software, in accordance with the requirements of SNI 1726-2019. The results indicate that buildings equipped with outrigger systems exhibit higher base shear force values compared to structures without outriggers, which helps ensure compliance with seismic design criteria. Conversely, the inclusion of outriggers significantly reduces the structural period, lateral displacement, and storey drift, demonstrating improved stiffness and deformation control. From a performance assessment perspective, particularly considering serviceability limit state criteria, the incorporation of outriggers effectively maintains inter-storey drift within acceptable limits, enhancing both safety and occupant comfort. The study concludes that the optimal configuration for a single outrigger installation is the existing location at Level 42, while for dual outriggers, the most effective arrangement combines the existing outrigger with an additional outrigger at Level 22. This configuration achieved the greatest improvement in reducing displacement and storey drift, confirming its suitability for enhancing the overall seismic performance of the high-rise structure. Moreover, by improving structural efficiency and resilience, the findings of this research contribute to the development of safer and more sustainable infrastructure that optimizes material use and extends the service life of tall buildings.
- Open Access
- 1 December 2025
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1564 (1)
Assessment of Natural Frequencies in Cable Structures Through Diagnostic Testing and Structural Health Monitoring Systems
Cable-stayed bridges are critical infrastructure whose safety and performance depend significantly on the structural integrity of their cables, which act as the main load-bearing elements. Over time, these cables can experience changes in dynamic characteristics due to factors such as tension loss, material degradation, or boundary condition variations, potentially compromising the stability and serviceability of the structure. To address this, accurate monitoring and evaluation of the natural frequencies of the cables are essential, as these frequencies serve as key indicators of structural condition. This study aims to analyze the natural frequency of cables on the cable-stayed bridge through dynamic testing using two accelerometer sensor systems, the BDI sensor for diagnostic testing and the BADU sensor for SHMS-based monitoring. The testing was conducted to obtain the natural frequency of the cables as an indicator of their actual structural condition and to compare the results with theoretical calculations. The test results show that the natural frequency of the cables is inversely proportional to their length, where longer cables such as SS8 and MS8 have lower frequencies compared to shorter cables such as SS1 and MS1. The comparison between the BDI and BADU sensor measurements indicates a relatively small difference, generally below 5%, suggesting that both systems can be used accurately for monitoring and verifying cable conditions. Furthermore, validation against theoretical values reveals that the field test results generally yield higher frequency values. This indicates that the actual cable conditions in the field have greater stiffness or tensile force than initially assumed in theoretical models. The study demonstrates that combining SHMS monitoring and diagnostic testing provides accurate and representative data on the dynamic behavior of bridge cables.
- 1 December 2025
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1564 (1)
Open AccessAssessment of Natural Frequencies in Cable Structures Through Diagnostic Testing and Structural Health Monitoring Systems
Cable-stayed bridges are critical infrastructure whose safety and performance depend significantly on the structural integrity of their cables, which act as the main load-bearing elements. Over time, these cables can experience changes in dynamic characteristics due to factors such as tension loss, material degradation, or boundary condition variations, potentially compromising the stability and serviceability of the structure. To address this, accurate monitoring and evaluation of the natural frequencies of the cables are essential, as these frequencies serve as key indicators of structural condition. This study aims to analyze the natural frequency of cables on the cable-stayed bridge through dynamic testing using two accelerometer sensor systems, the BDI sensor for diagnostic testing and the BADU sensor for SHMS-based monitoring. The testing was conducted to obtain the natural frequency of the cables as an indicator of their actual structural condition and to compare the results with theoretical calculations. The test results show that the natural frequency of the cables is inversely proportional to their length, where longer cables such as SS8 and MS8 have lower frequencies compared to shorter cables such as SS1 and MS1. The comparison between the BDI and BADU sensor measurements indicates a relatively small difference, generally below 5%, suggesting that both systems can be used accurately for monitoring and verifying cable conditions. Furthermore, validation against theoretical values reveals that the field test results generally yield higher frequency values. This indicates that the actual cable conditions in the field have greater stiffness or tensile force than initially assumed in theoretical models. The study demonstrates that combining SHMS monitoring and diagnostic testing provides accurate and representative data on the dynamic behavior of bridge cables.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3026 (1)
Bridge deflection estimates from the measured rotation value of a steel truss bridge
Structural health monitoring (SHM) system is carried out to ensure that a bridge structure remains in service condition. The bridge deflection measurement metho
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3026 (1)
Bridge deflection estimates from the measured rotation value of a steel truss bridge
Structural health monitoring (SHM) system is carried out to ensure that a bridge structure remains in service condition. The bridge deflection measurement metho
- Open Access
- 20 April 2023
- Published by IEOM Society International
- Vol. 12 (4)
Effect of Sample Rate on Frequency Values in Sinusoidal Signals
Analog signals are generally expressed by sinusoidal waves, where sinusoidal waves are the basis for all forms of analog signals. The important parameters of the sinusoidal signal equation are frequency (f n) and sample rate (f s) which are formulated with the equation x(t) = sin 2πf n t. The time parameter in the t variable in the sinusoidal equation is the duration of data collection for the sinusoidal signal. Frequency data in this study uses two models, namely the first model with a frequency value of f 1 = 0.25Hz, f 2 = 1.5Hz, f 3 = 3Hz and the second model with a frequency value of f 1 = 0.25Hz, f 2 = 2Hz, f 3 = 4.25Hz. The sample rate (f s) used for both models is 8 Hz with a total time duration of 32 seconds. The method used in transforming the time domain of a sinusoidal signal into a frequency domain is using the Discrete Fourier Transform. The results obtained for the first model, namely the reading of the frequency value of f 1 = 0.25Hz, f 2 = 1.5Hz, f 3 = 3Hz can still be read clearly. As for the second model, the frequency value of f 1 = 0.25Hz, f 2 = 2Hz, f 3 = 4.25Hz can still be read. However, a new frequency appears between the frequency readings of f 2 = 2Hz and f 3 = 4.25 Hz, with a frequency value of f = 3.75Hz. This is because the use of the sample rate (f s = 8 Hz) is smaller than 2 times the signal frequency (2 f n). Therefore, the Nyquist theory in the case study of the second model does not meet the equation f s > 2 f n .
- 20 April 2023
- Published by IEOM Society International
- Vol. 12 (4)
Open AccessEffect of Sample Rate on Frequency Values in Sinusoidal Signals
Analog signals are generally expressed by sinusoidal waves, where sinusoidal waves are the basis for all forms of analog signals. The important parameters of the sinusoidal signal equation are frequency (f n) and sample rate (f s) which are formulated with the equation x(t) = sin 2πf n t. The time parameter in the t variable in the sinusoidal equation is the duration of data collection for the sinusoidal signal. Frequency data in this study uses two models, namely the first model with a frequency value of f 1 = 0.25Hz, f 2 = 1.5Hz, f 3 = 3Hz and the second model with a frequency value of f 1 = 0.25Hz, f 2 = 2Hz, f 3 = 4.25Hz. The sample rate (f s) used for both models is 8 Hz with a total time duration of 32 seconds. The method used in transforming the time domain of a sinusoidal signal into a frequency domain is using the Discrete Fourier Transform. The results obtained for the first model, namely the reading of the frequency value of f 1 = 0.25Hz, f 2 = 1.5Hz, f 3 = 3Hz can still be read clearly. As for the second model, the frequency value of f 1 = 0.25Hz, f 2 = 2Hz, f 3 = 4.25Hz can still be read. However, a new frequency appears between the frequency readings of f 2 = 2Hz and f 3 = 4.25 Hz, with a frequency value of f = 3.75Hz. This is because the use of the sample rate (f s = 8 Hz) is smaller than 2 times the signal frequency (2 f n). Therefore, the Nyquist theory in the case study of the second model does not meet the equation f s > 2 f n .
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2947 (1) , 020003
Correlation of normal concrete compressive strength with destructive and non-destructive test methods
An investigation has been made to perceive the correlation of normal concrete compressive strength between the destructive and non-destructive test method. The
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2947 (1) , 020003
Open AccessCorrelation of normal concrete compressive strength with destructive and non-destructive test methods
An investigation has been made to perceive the correlation of normal concrete compressive strength between the destructive and non-destructive test method. The
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2846 (1)
Implementation of wavelet transformation in analyzing and reconstructing a noisy sinusoidal signal
Noise is the main issue that commonly occurs in taking and processing the signal. The noise may interfere with the first vibration mode frequency based on the results of Fast Fourier Transform. Previous study carried out using signals with sinusoidal functions has been able to minimize the noise in a signal. However, there is limited information about the time or location the frequency value of a signal takes place. For this reason, wavelet transforms are reapplied in reconstructing signals to provide information on the frequency and time. In this study, signal data with sinusoidal functions is used with a specified frequency of 0.25 Hz. The signal data is subjected to noise with a range of standard deviation 0.1 - 1.0. Wavelet analysis used is Haar wavelet, while the signal filtering process used high-pass and low-pass filter. The filtering lengths used are 8 (23) and 32 (25), so it will produce 8*8 and 32*32 Haar wavelet analysis matrics. The results show that the specified frequency value can be determined using signal analysis with Haar wavelet analysis and signal reconstruction. The higher the scale paramater value (j) is used in signal analysis and filtering, the higher range of noise values can be reduced. The results also indicated that the signal frequency can be obtained when there is a similar pattern between the reconstruction and original signal.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2846 (1)
Open AccessImplementation of wavelet transformation in analyzing and reconstructing a noisy sinusoidal signal
Noise is the main issue that commonly occurs in taking and processing the signal. The noise may interfere with the first vibration mode frequency based on the results of Fast Fourier Transform. Previous study carried out using signals with sinusoidal functions has been able to minimize the noise in a signal. However, there is limited information about the time or location the frequency value of a signal takes place. For this reason, wavelet transforms are reapplied in reconstructing signals to provide information on the frequency and time. In this study, signal data with sinusoidal functions is used with a specified frequency of 0.25 Hz. The signal data is subjected to noise with a range of standard deviation 0.1 - 1.0. Wavelet analysis used is Haar wavelet, while the signal filtering process used high-pass and low-pass filter. The filtering lengths used are 8 (23) and 32 (25), so it will produce 8*8 and 32*32 Haar wavelet analysis matrics. The results show that the specified frequency value can be determined using signal analysis with Haar wavelet analysis and signal reconstruction. The higher the scale paramater value (j) is used in signal analysis and filtering, the higher range of noise values can be reduced. The results also indicated that the signal frequency can be obtained when there is a similar pattern between the reconstruction and original signal.
- Open Access
- 1 July 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 794 (1) , 012032
Modeling existing buildings three-dimensional (3D) using unmanned aerial vehicles: A study case in Binus Syahdan Campus Building
Developments in the field of photogrammetric technology using UAV (Unmanned Aerial Vehicle) make it easier to represent mapping results quickly and accurately. Along with the growing need for spatial use, both horizontally and vertically, have implications for the need of accurate spatial data both in two-dimensional (2D) or three-dimensional (3D) space. 3D visualization and modeling is a representation of the surface of the earth with the aim of supplying the appearance of the earth along with the whole above it more realistic and able to provide a broader perspective compared to 2D visualization or conventional maps. In this study, the drone-based UAV was used, namely DJI Mavic Air to collect geometric data on the Syahdan campus. The digital data that has been recorded by the UAV is then processed into three-dimensional modeling using DroneDeploy software. DroneDeploy software is cloud-based and is generally used for aerial mapping, in this study it is used in making 3D modeling because of its efficient. The elevation data at each building point measured using a drone-based UAV are compared with the as-built drawing of the Syahdan Campus, Binus. The root mean square value of the comparison of elevation distance between 3D model and as built drawing is 0.47 meters.
- 1 July 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 794 (1) , 012032
Open AccessModeling existing buildings three-dimensional (3D) using unmanned aerial vehicles: A study case in Binus Syahdan Campus Building
Developments in the field of photogrammetric technology using UAV (Unmanned Aerial Vehicle) make it easier to represent mapping results quickly and accurately. Along with the growing need for spatial use, both horizontally and vertically, have implications for the need of accurate spatial data both in two-dimensional (2D) or three-dimensional (3D) space. 3D visualization and modeling is a representation of the surface of the earth with the aim of supplying the appearance of the earth along with the whole above it more realistic and able to provide a broader perspective compared to 2D visualization or conventional maps. In this study, the drone-based UAV was used, namely DJI Mavic Air to collect geometric data on the Syahdan campus. The digital data that has been recorded by the UAV is then processed into three-dimensional modeling using DroneDeploy software. DroneDeploy software is cloud-based and is generally used for aerial mapping, in this study it is used in making 3D modeling because of its efficient. The elevation data at each building point measured using a drone-based UAV are compared with the as-built drawing of the Syahdan Campus, Binus. The root mean square value of the comparison of elevation distance between 3D model and as built drawing is 0.47 meters.
- Open Access
- 1 February 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 426 (1)
Seismic performance of reinforced concrete structures with pushover analysis
A building that looks strong enough might possibly collapse due to the earthquake load. Earthquake resistant design is generally based on an analysis of elastic structures that are given a load factor to simulate ultimate conditions. When an earthquake occurs, the collapse behavior of a building structure is inelastic. Evaluations that can estimate the inelastic condition of buildings during an earthquake are analyzed using pushover analysis. Pushover analysis is the nonlinear static load of the structural collapse behavior of an earthquake, while the performance point is the magnitude of the maximum displacement of the structure during a earthquake. The inelastic structure analysis and evaluation method used computer application SAP 2000. Evaluation results of structural performance levels according to Applied Technology Council 40 (ATC-40) on the X and Y direction structure, the maximum total drift and total inelastic drift maximum values in the X and Y directions included in the Immediate Occupancy (IO) level category (maximum drift value of a building structure 0.00047 < 0.005).
- 1 February 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 426 (1)
Open AccessSeismic performance of reinforced concrete structures with pushover analysis
A building that looks strong enough might possibly collapse due to the earthquake load. Earthquake resistant design is generally based on an analysis of elastic structures that are given a load factor to simulate ultimate conditions. When an earthquake occurs, the collapse behavior of a building structure is inelastic. Evaluations that can estimate the inelastic condition of buildings during an earthquake are analyzed using pushover analysis. Pushover analysis is the nonlinear static load of the structural collapse behavior of an earthquake, while the performance point is the magnitude of the maximum displacement of the structure during a earthquake. The inelastic structure analysis and evaluation method used computer application SAP 2000. Evaluation results of structural performance levels according to Applied Technology Council 40 (ATC-40) on the X and Y direction structure, the maximum total drift and total inelastic drift maximum values in the X and Y directions included in the Immediate Occupancy (IO) level category (maximum drift value of a building structure 0.00047 < 0.005).
- Open Access
- 1 February 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 426 (1)
Displacement and curvature ductility in mid-rise reinforced concrete buildings
When an earthquake occurs, ductility will maintain strength and stiffness in the structure so that the building structure still works even though it is on the verge of collapse. To get a description of the structural behavior starting from the structure in linear elastic, the first yielding of the structural elements until the structure collapse due to earthquake load, it can be done with non-linear static analysis namely pushover analysis. In this study, the geometry of mid-rise reinforced concrete structure consists of four storey buildings. The dimensions of the column structure 400x400 mm and beam structure 250x500 mm, where the dimensions of the beams and columns are the same from the 1st floor to the 4th floor. To find out the behavior that affects the ductility value in mid-rise reinforced concrete structures, a variation material used in this study are the spacing of stirrup, ratio of longitudinal reinforcement, ratio of compressive and tensile longitudinal reinforcement, and compressive strength of concrete. Structural geometry modeling, structural loads, and modeling of material variations used the program SAP 2000. From the output of this program, an analysis of the value of curvature ductility and displacement ductility was performed. The result of this study are the higher the value of compressive strength of concrete and the ratio of longitudinal reinforcement in beam structure will increase the value of ductility. The smaller the value of the spacing of stirrup and the ratio of longitudinal reinforcement in column structure will increase the value of ductility.
- 1 February 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 426 (1)
Open AccessDisplacement and curvature ductility in mid-rise reinforced concrete buildings
When an earthquake occurs, ductility will maintain strength and stiffness in the structure so that the building structure still works even though it is on the verge of collapse. To get a description of the structural behavior starting from the structure in linear elastic, the first yielding of the structural elements until the structure collapse due to earthquake load, it can be done with non-linear static analysis namely pushover analysis. In this study, the geometry of mid-rise reinforced concrete structure consists of four storey buildings. The dimensions of the column structure 400x400 mm and beam structure 250x500 mm, where the dimensions of the beams and columns are the same from the 1st floor to the 4th floor. To find out the behavior that affects the ductility value in mid-rise reinforced concrete structures, a variation material used in this study are the spacing of stirrup, ratio of longitudinal reinforcement, ratio of compressive and tensile longitudinal reinforcement, and compressive strength of concrete. Structural geometry modeling, structural loads, and modeling of material variations used the program SAP 2000. From the output of this program, an analysis of the value of curvature ductility and displacement ductility was performed. The result of this study are the higher the value of compressive strength of concrete and the ratio of longitudinal reinforcement in beam structure will increase the value of ductility. The smaller the value of the spacing of stirrup and the ratio of longitudinal reinforcement in column structure will increase the value of ductility.
- Open Access
- 14 December 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 195 (1) , 012022
Validation value of cable force using the accelerometer
- 14 December 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 195 (1) , 012022
Open AccessValidation value of cable force using the accelerometer