Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T
- 14 January 2014
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 41 (2) , 022302
Abstract
Purpose:: To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm.Materials:: Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast spoiled gradient echo, and 3D time‐of‐flight) by using a 7T MRI system. Intensity inhomogeneity correction was performed using the “New Segment” module in SPM8 with four different values (120, 90, 60, and 30 mm) of full width at half maximum (FWHM) in Gaussian smoothness. The uniformity in signals in the entire white matter was evaluated using the coefficient of variation (CV); mean signal intensities between the subcortical and deep white matter were compared, and contrast between subcortical white matter and gray matter was measured. The length of the lenticulostriate (LSA) was measured on maximum intensity projection (MIP) images in the original and corrected images.Results:: In all sequences, the CV decreased as the FWHM value decreased. The differences of mean signal intensities between subcortical and deep white matter also decreased with smaller FWHM values. The contrast between white and gray matter was maintained at all FWHM values. LSA length was significantly greater in corrected MIP than in the original MIP images.Conclusions:: Intensity inhomogeneity in 7T MRI can be successfully corrected using SPM8 for various scan sequences.Keywords
Funding Information
- Council for Science and Technology Policy (CSTP) and JSPS KAKENHI (13281909)
This publication has 38 references indexed in Scilit:
- Ultrahigh field systems and applications at 7 T and beyond: Progress, pitfalls, and potentialMagnetic Resonance in Medicine, 2011
- Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIREuropean Radiology, 2011
- Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT)NeuroImage, 2011
- Simple analytical dual-band spectral-spatial RF pulses for B1+ and susceptibility artifact reduction in gradient echo MRIMagnetic Resonance in Medicine, 2010
- Fast algorithm for calculation of inhomogeneity gradient in magnetic resonance imaging dataJournal of Magnetic Resonance Imaging, 2010
- RF shimming for spectroscopic localization in the human brain at 7 TMagnetic Resonance in Medicine, 2009
- T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2⁎ contrast and RF coil receive B1 sensitivity with simultaneous vessel visualizationNeuroImage, 2009
- High-flip-angle slice-selective parallel RF transmission with 8 channels at 7TJournal of Magnetic Resonance, 2008
- Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coilsNeuroImage, 2008
- Detunable transverse electromagnetic (TEM) volume coil for high‐field NMRMagnetic Resonance in Medicine, 2002