RF shimming for spectroscopic localization in the human brain at 7 T
Open Access
- 13 November 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (1) , 9-19
Abstract
Spectroscopic imaging of the human head at short echo times (≤15 ms) typically requires suppression of signals from extracerebral tissues. However, at 7 T, decreasing efficiency in B generation (hertz/watt) and increasing spectral bandwidth result in dramatic increases in power deposition and increased chemical shift registration artifacts for conventional gradient‐based in‐plane localization. In this work, we describe a novel method using radiofrequency shimming and an eight‐element transceiver array to generate a B field distribution that excites a ring about the periphery of the head and leaves central brain regions largely unaffected. We have used this novel B distribution to provide in‐plane outer volume suppression (>98% suppression of extracerebral lipids) without the use of gradients. This novel B distribution is used in conjunction with a double inversion recovery method to provide suppression of extracerebral resonances with T1s greater than 400 ms, while having negligible effect on metabolite ratios of cerebral resonances with T1s > 1000 ms. Despite the use of two adiabatic pulses, the high efficiency of the ring distribution allows radiofrequency power deposition to be limited to 3‐4 W for a pulse repetition time of 1.5 sec. The short echo time enabled the acquisition of images of the human brain, displaying glutamate, glutamine, macromolecules, and other major cerebral metabolites. Magn Reson Med, 2010.Keywords
Funding Information
- Unknown funding agency (R01-EB-009871, RO1-EB-00473)
This publication has 30 references indexed in Scilit:
- Consideration of physiological response in numerical models of temperature during MRI of the human headJournal of Magnetic Resonance Imaging, 2008
- High-flip-angle slice-selective parallel RF transmission with 8 channels at 7TJournal of Magnetic Resonance, 2008
- Interleaved narrow‐band PRESS sequence with adiabatic spatial‐spectral refocusing pulses for 1H MRSI at 7TMagnetic Resonance in Medicine, 2008
- Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recoveryMagnetic Resonance in Medicine, 2008
- Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulsesMagnetic Resonance Materials in Physics, Biology and Medicine, 2008
- Quantitative glutamate spectroscopic imaging of the human hippocampusNMR in Biomedicine, 2006
- 2D 1H spectroscopic imaging of the human brain at 4.1 TMagnetic Resonance in Medicine, 1994
- High frequency volume coils for clinical NMR imaging and spectroscopyMagnetic Resonance in Medicine, 1994
- Characterization of macromolecule resonances in the 1H NMR spectrum of rat brainMagnetic Resonance in Medicine, 1993
- Quantitation of metabolites by 1H NMRMagnetic Resonance in Medicine, 1991