Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation
Open Access
- 3 April 2018
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 1-7
Abstract
Complications related to extensor tendons have begun to increase with the use of volar plates in the treatment of distal radius fractures. In this study, we aimed to compare four-plane radiography and ultrasonography in the evaluation of dorsal cortex screw penetration following volar plate fixation. We recruited 47 patients (33 males, 14 females, mean age 37.4 years; range 18–58 years). To evaluate dorsal screw penetration in all patients, we performed radiographs at 45° pronation, 45° supination and obtained dorsal tangential graphs at maximum palmar flexion, and a wrist lateral radiograph. Wrist ultrasonography was performed in all patients. Dorsal screw penetration was detected in 12 of the 47 patients undergoing VLP application. While there was > 2 mm screw penetration in seven patients, there was < 2 mm screw penetration in five patients. On four-plane radiographs, screw penetration > 2 mm was detected in seven patients and screw penetration < 2 mm was detected in two patients. On four-plane radiography, dorsal screw penetration was not detected in three out of five patients, who were shown to have < 2 mm screw penetration by ultrasonography. In addition to perioperative four-plane radiographs are also required to detect dorsal cortex penetration in patients undergoing VLP due to distal radius fracture. However, the detection of screw penetrations < 2 mm is more likely with ultrasonography compared to four-plane radiography. We recommend that dorsal cortex screw penetration should be evaluated with perioperative ultrasonography. Research Registry, researchregistry3344 , Registered 10 January 2017Keywords
This publication has 14 references indexed in Scilit:
- Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric studyThe Annals of The Royal College of Surgeons of England, 2016
- Ultrasound Imaging Improves Identification of Prominent Hardware in the Surgical Treatment of Distal Radius Fractures: A Cadaveric and Prospective Clinical StudyJournal of Wrist Surgery, 2015
- Dorsal Screw Penetration With the Use of Volar Plating of Distal Radius FracturesJournal of Orthopaedic Trauma, 2015
- Complications of distal radius locking platesInjury, 2013
- Comparison of 4 Fluoroscopic Views for Dorsal Cortex Screw Penetration After Volar Plating of the Distal RadiusThe Journal of Hand Surgery, 2012
- Screw prominences related to palmar locking plating of distal radiusJournal of Hand Surgery (European Volume), 2011
- Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle PlatingHAND, 2011
- Screw Impingement on the Extensor Tendons in Distal Radius Fractures Treated by Volar Plating: Sonographic AppearanceAmerican Journal of Roentgenology, 2008
- Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fracturesThe Journal of Bone and Joint Surgery. British volume, 2006
- THE TREATMENT OF UNSTABLE DISTAL RADIUS FRACTURES WITH VOLAR FIXATIONHand Surgery, 2000