Use of BACTEC MGIT 960 for Recovery of Mycobacteria from Clinical Specimens: Multicenter Study
Authors:
- 1 November 1999
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 37 (11) , 3578-82
Abstract
The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automatic systems and for 8 weeks on solid media. A total of 2,567 specimens obtained from 1,631 patients were cultured in parallel. Mycobacteria belonging to nine different taxa were isolated by at least one of the culture systems, with 75% of them being represented by Mycobacterium tuberculosis complex. The best yield was obtained with the BACTEC 460 system, with 201 isolates, in comparison with 190 isolates with the BACTEC MGIT 960 system and 168 isolates with Lowenstein-Jensen medium. A similar but not significant difference was obtained when the most-represented organisms, the M. tuberculosis complex, Mycobacterium xenopi , and the Mycobacterium avium complex, were analyzed separately and when combinations of a solid medium with the BACTEC MGIT 960 system and with the BACTEC 460 system were considered. The shortest times to detection were obtained with the BACTEC MGIT 960 system (13.3 days); 1.5 days earlier than that with the BACTEC 460 system (14.8 days) and 12 days earlier than that with Lowenstein-Jensen medium (25.6 days). The BACTEC MGIT 960 system had a contamination rate of 10.0%, intermediate between those of the radiometric system (3.7%) and the egg-based medium (17.0%). We conclude, therefore, that the BACTEC MGIT 960 system is a fully automated, nonradiometric instrument that is suitable for the detection of growth of tuberculous and other mycobacterial species and that is characterized by detection times that are even shorter than that of the “gold standard,” the BACTEC 460 system. The contamination rate was higher than that for the radiometric BACTEC 460 system and needs to be improved.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of the Mycobacteria Growth Indicator Tube with MB Redox, Löwenstein-Jensen, and Middlebrook 7H11 Media for Recovery of Mycobacteria in Clinical SpecimensJournal of Clinical Microbiology, 1999
- Multicenter Evaluation of the BACTEC MGIT 960 System for Recovery of MycobacteriaJournal of Clinical Microbiology, 1999
- Multicenter Comparison of ESP Culture System II with BACTEC 460TB and with Lowenstein-Jensen Medium for Recovery of Mycobacteria from Different Clinical Specimens, Including BloodJournal of Clinical Microbiology, 1998
- Evaluation of the MB/BacT system and comparison to the BACTEC 460 system and solid media for isolation of mycobacteria from clinical specimensJournal of Clinical Microbiology, 1997
- Evaluation of a nonradiometric system (BACTEC 9000 MB) for detection of mycobacteria in human clinical samplesJournal of Clinical Microbiology, 1997
- MYCOBACTERIOLOGY LABORATORYClinics in Chest Medicine, 1997
- High-performance liquid chromatography and identification of mycobacteriaReviews and Research in Medical Microbiology, 1996
- Essential components of a tuberculosis prevention and control program. Recommendations of the Advisory Council for the Elimination of Tuberculosis.1995
- Application of New Technology to the Detection, Identification, and Antimicrobial Susceptibility Testing of MycobacteriaAmerican Journal of Clinical Pathology, 1994
- Conventional identification characteristics, mycolate and fatty acid composition, and clinical significance of MAIX AccuProbe-positive isolates of Mycobacterium avium complexJournal of Clinical Microbiology, 1993