Correlation electron cyclotron emission diagnostic and improved calculation of turbulent temperature fluctuation levels on ASDEX Upgrade
- 1 May 2018
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (5) , 053503
Abstract
A newly upgraded correlation electron cyclotron emission (CECE) diagnostic has been installed on the ASDEX Upgrade tokamak and has begun to perform experimental measurements of electron temperature fluctuations. CECE diagnostics measure small amplitude electron temperature fluctuations by correlating closely spaced heterodyne radiometer channels. This upgrade expanded the system from six channels to thirty, allowing simultaneous measurement of fluctuation level radial profiles without repeat discharges, as well as opening up the possibility of measuring radial turbulent correlation lengths. Newly refined statistical techniques have been developed in order to accurately analyze the fluctuation data collected from the CECE system. This paper presents the hardware upgrades for this system and the analysis techniques used to interpret the raw data, as well as measurements of fluctuation spectra and fluctuation level radial profiles.Keywords
Funding Information
- U.S. Department of War (NDSEG)
- U.S. Department of Energy (DE-SC0006419, DE-SC0017381)
- FP7 Fusion Energy Research (633053)
This publication has 27 references indexed in Scilit:
- Spatially resolved measurements of two-dimensional turbulent structures in DIII-D plasmasPhysics of Plasmas, 2015
- Nonlinear gyrokinetic simulations of the I-mode high confinement regime and comparisons with experimenta)Physics of Plasmas, 2015
- Measurement of electron temperature fluctuations using a tunable correlation electron cyclotron emission system on Alcator C-ModReview of Scientific Instruments, 2014
- Design of a correlation electron cyclotron emission diagnostic for Alcator C-ModReview of Scientific Instruments, 2012
- Implementation and application of two synthetic diagnostics for validating simulations of core tokamak turbulencePhysics of Plasmas, 2009
- A correlation electron cyclotron emission diagnostic and the importance of multifield fluctuation measurements for testing nonlinear gyrokinetic turbulence simulationsReview of Scientific Instruments, 2008
- Measurement of temperature fluctuations from electron cyclotron emissionReview of Scientific Instruments, 1995
- A unifying view of coherence in signal processingSignal Processing, 1992
- A note on cross spectrum and coherence calculationsJournal of Geophysical Research: Oceans, 1982
- Generalized harmonic analysisActa Mathematica, 1930