W. Burke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
W. Burke has a total of 225 co-authors. Here are the top co-authors by number of shared publications:
- A. E. White
Plasma Science and Fusion Center, Massachusetts Institute of Technology 1 , Cambridge, Massachusetts 02139
3 shared publications - Branka Vanovac
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, United States of America
3 shared publications - C. Yoo
Plasma Science and Fusion Center, Massachusetts Institute of Technology 1 , Cambridge, Massachusetts 02139
3 shared publications - Garrard D. Conway
Max Planck Institute for Plasma Physics 2 , Boltzmannstr. 2, 85748 Garching
3 shared publications - Rachel Bielajew
Plasma Science and Fusion Center, Massachusetts Institute of Technology 1 , Cambridge, Massachusetts 02139
3 shared publications A. E. White
MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
2 shared publications
Latest Publications
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels
A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels
A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (1) , 015004
Edge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic
The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D– α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δ T rad / T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, f QCM ≈ 20 − 50 kHz; spectral width, Δ f ≈ 5 − 40 kHz; δ T rad / T rad ≈ 4 − 6 % ; and L c ≈ 1 − 2 cm. Investigations into a quantity representing the relative bandwidth Δ f / f QCM revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.
- 1 January 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (1) , 015004
Open AccessEdge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic
The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D– α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δ T rad / T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, f QCM ≈ 20 − 50 kHz; spectral width, Δ f ≈ 5 − 40 kHz; δ T rad / T rad ≈ 4 − 6 % ; and L c ≈ 1 − 2 cm. Investigations into a quantity representing the relative bandwidth Δ f / f QCM revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade
This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade
This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.
- Open Access
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-16
Building the Runway: A New Superconducting Magnet Test Facility Made for the SPARC Toroidal Field Model Coil
A new superconducting magnet test facility was created at the MIT Plasma Science and Fusion Center (PSFC) for the SPARC Toroidal Field Model Coil (TFMC) program. The facility was designed and constructed in parallel with the TFMC between 2019 and 2021, with capabilities and design approaches tailored to the needs of this project and its time line. The major components of the facility include a new cryostat (outer dimensions, 5.3 m × 3.7 m × 1.5 m) with open bore; a novel cooling system circulating supercritical helium in a closed loop to provide $\sim$ 600 W cooling power at $\sim$ 20 bar-a, $\sim$ 20 K; a 50-kA $\pm$ 10-V power supply with supporting nitrogen-cooled high temperature superconductor (HTS) binary current leads operating at record currents, as well as VIPER-cable HTS cold bus; and a new instrumentation and programmable-logic-controller-based control system handling $\sim$ 650 input and output signals distributed between the facility and the test article. Substantial legacy infrastructure inherited from the PSFC's Alcator C-Mod tokamak program, including liquid nitrogen facilities and 10 mW of ac power, was instrumental in the rapid deployment of these new systems. Immediately after initial commissioning, the facility was used successfully to test the SPARC TFMC, operating the magnet in a campaign achieving 20 T on the coil, as well as a second campaign performing quench testing. The facility has since undergone several upgrades and has been used in campaigns of other test articles, and it is expected that the facility will remain a resource for the community for the foreseeable future to develop fusion magnets and related technology.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-16
Open AccessBuilding the Runway: A New Superconducting Magnet Test Facility Made for the SPARC Toroidal Field Model Coil
A new superconducting magnet test facility was created at the MIT Plasma Science and Fusion Center (PSFC) for the SPARC Toroidal Field Model Coil (TFMC) program. The facility was designed and constructed in parallel with the TFMC between 2019 and 2021, with capabilities and design approaches tailored to the needs of this project and its time line. The major components of the facility include a new cryostat (outer dimensions, 5.3 m × 3.7 m × 1.5 m) with open bore; a novel cooling system circulating supercritical helium in a closed loop to provide $\sim$ 600 W cooling power at $\sim$ 20 bar-a, $\sim$ 20 K; a 50-kA $\pm$ 10-V power supply with supporting nitrogen-cooled high temperature superconductor (HTS) binary current leads operating at record currents, as well as VIPER-cable HTS cold bus; and a new instrumentation and programmable-logic-controller-based control system handling $\sim$ 650 input and output signals distributed between the facility and the test article. Substantial legacy infrastructure inherited from the PSFC's Alcator C-Mod tokamak program, including liquid nitrogen facilities and 10 mW of ac power, was instrumental in the rapid deployment of these new systems. Immediately after initial commissioning, the facility was used successfully to test the SPARC TFMC, operating the magnet in a campaign achieving 20 T on the coil, as well as a second campaign performing quench testing. The facility has since undergone several upgrades and has been used in campaigns of other test articles, and it is expected that the facility will remain a resource for the community for the foreseeable future to develop fusion magnets and related technology.
- 1 May 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (5) , 053503
Correlation electron cyclotron emission diagnostic and improved calculation of turbulent temperature fluctuation levels on ASDEX Upgrade
A newly upgraded correlation electron cyclotron emission (CECE) diagnostic has been installed on the ASDEX Upgrade tokamak and has begun to perform experimental measurements of electron temperature fluctuations. CECE diagnostics measure small amplitude electron temperature fluctuations by correlating closely spaced heterodyne radiometer channels. This upgrade expanded the system from six channels to thirty, allowing simultaneous measurement of fluctuation level radial profiles without repeat discharges, as well as opening up the possibility of measuring radial turbulent correlation lengths. Newly refined statistical techniques have been developed in order to accurately analyze the fluctuation data collected from the CECE system. This paper presents the hardware upgrades for this system and the analysis techniques used to interpret the raw data, as well as measurements of fluctuation spectra and fluctuation level radial profiles.
- 1 May 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (5) , 053503
Correlation electron cyclotron emission diagnostic and improved calculation of turbulent temperature fluctuation levels on ASDEX Upgrade
A newly upgraded correlation electron cyclotron emission (CECE) diagnostic has been installed on the ASDEX Upgrade tokamak and has begun to perform experimental measurements of electron temperature fluctuations. CECE diagnostics measure small amplitude electron temperature fluctuations by correlating closely spaced heterodyne radiometer channels. This upgrade expanded the system from six channels to thirty, allowing simultaneous measurement of fluctuation level radial profiles without repeat discharges, as well as opening up the possibility of measuring radial turbulent correlation lengths. Newly refined statistical techniques have been developed in order to accurately analyze the fluctuation data collected from the CECE system. This paper presents the hardware upgrades for this system and the analysis techniques used to interpret the raw data, as well as measurements of fluctuation spectra and fluctuation level radial profiles.
- 1 September 2012
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 207 (3) , A1-A14
Table of Contents
- 1 September 2012
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 207 (3) , A1-A14
Table of Contents