Performance Improvement of a Grid-Connected Inverter under Distorted Grid Voltage Using a Harmonic Extractor
Open Access
- 16 September 2019
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 8 (9) , 1038
Abstract
This paper introduces an improved current control strategy for a grid-connected inverter system operating under distorted grid voltage conditions. Although existing current controllers for grid-connected inverters have proportional integral gains with suitable bandwidth, low-order harmonic components can be generated by distorted grid voltages. The proposed improved current controller is established in a synchronous reference frame that rotates at harmonic frequency. The input signals for the harmonic current controller should contain only the specific harmonic components requiring suppression. Therefore, the proposed current controller uses a harmonic extractor to distinguish current signals from fundamental and specific harmonic components. The harmonic extractor retains only the relevant harmonic components for individual current controllers with high harmonic signal ratios. This paper introduces two different strategies to extract specific harmonic components for the current controller. The proposed control strategy does not require any additional hardware filter circuits and can be implemented easily by designing a suitable digital filter. When using the proposed method, grid current quality is significantly improved compared to conventional methods that do not include harmonic extractors. The effectiveness of the proposed method is verified through simulations and practical experiments.Keywords
This publication has 23 references indexed in Scilit:
- A Stochastic Stability Enhancement Method of Grid-Connected Distributed Energy Storage SystemsIEEE Transactions on Smart Grid, 2016
- An Improved Grid-Voltage Feedforward Strategy for High-Power Three-Phase Grid-Connected Inverters Based on the Simplified Repetitive PredictorIEEE Transactions on Power Electronics, 2015
- A Review of Architectures and Concepts for Intelligence in Future Electric Energy SystemsIEEE Transactions on Industrial Electronics, 2014
- Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid VoltagesJournal of Power Electronics, 2013
- Second-Order Harmonic Reduction Technique for Photovoltaic Power Conditioning Systems Using a Proportional-Resonant ControllerEnergies, 2013
- Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR ControllerJournal of Electrical Engineering & Technology, 2012
- Reduction of Current Harmonic Distortion in Three-Phase Grid-Connected Photovoltaic Inverters via Resonant Current ControlIEEE Transactions on Industrial Electronics, 2011
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006
- Proportional-resonant controllers and filters for grid-connected voltage-source convertersIEE Proceedings - Electric Power Applications, 2006
- Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frameIEEE Transactions on Power Electronics, 2006