Ho-Sung Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ho-Sung Kang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kyo-Beum Lee
Department of Electrical and Computer Engineering, Ajou University, Suwon-si, Korea
2 shared publications - Ji-Yoon Yoo
School of Electrical Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
1 shared publication - Seok-Min Kim
Department of Electrical and Computer Engineering, Ajou University, Suwon Korea (the Republic of) 443-749
1 shared publication - Sungjoon Cho
Department of Electrical and Computer Engineering, Ajou University, 206, World cup-row, Yeongtong-gu, Suwon 16499, Korea
1 shared publication
Latest Publications
- Open Access
- 16 September 2019
- Published by MDPI AG in Electronics
- Vol. 8 (9) , 1038
Performance Improvement of a Grid-Connected Inverter under Distorted Grid Voltage Using a Harmonic Extractor
This paper introduces an improved current control strategy for a grid-connected inverter system operating under distorted grid voltage conditions. Although existing current controllers for grid-connected inverters have proportional integral gains with suitable bandwidth, low-order harmonic components can be generated by distorted grid voltages. The proposed improved current controller is established in a synchronous reference frame that rotates at harmonic frequency. The input signals for the harmonic current controller should contain only the specific harmonic components requiring suppression. Therefore, the proposed current controller uses a harmonic extractor to distinguish current signals from fundamental and specific harmonic components. The harmonic extractor retains only the relevant harmonic components for individual current controllers with high harmonic signal ratios. This paper introduces two different strategies to extract specific harmonic components for the current controller. The proposed control strategy does not require any additional hardware filter circuits and can be implemented easily by designing a suitable digital filter. When using the proposed method, grid current quality is significantly improved compared to conventional methods that do not include harmonic extractors. The effectiveness of the proposed method is verified through simulations and practical experiments.
- 16 September 2019
- Published by MDPI AG in Electronics
- Vol. 8 (9) , 1038
Open AccessPerformance Improvement of a Grid-Connected Inverter under Distorted Grid Voltage Using a Harmonic Extractor
This paper introduces an improved current control strategy for a grid-connected inverter system operating under distorted grid voltage conditions. Although existing current controllers for grid-connected inverters have proportional integral gains with suitable bandwidth, low-order harmonic components can be generated by distorted grid voltages. The proposed improved current controller is established in a synchronous reference frame that rotates at harmonic frequency. The input signals for the harmonic current controller should contain only the specific harmonic components requiring suppression. Therefore, the proposed current controller uses a harmonic extractor to distinguish current signals from fundamental and specific harmonic components. The harmonic extractor retains only the relevant harmonic components for individual current controllers with high harmonic signal ratios. This paper introduces two different strategies to extract specific harmonic components for the current controller. The proposed control strategy does not require any additional hardware filter circuits and can be implemented easily by designing a suitable digital filter. When using the proposed method, grid current quality is significantly improved compared to conventional methods that do not include harmonic extractors. The effectiveness of the proposed method is verified through simulations and practical experiments.
- Open Access
- 1 November 2018
- Published by MDPI AG in Electronics
- Vol. 7 (11) , 287
Single-Phase Bidirectional On-Board Charger Using Starter Generator System in Hybrid Electric Vehicles
This paper presents the design and control methods of a single-phase bidirectional on-board charger (OBC) using a hybrid starter generator (HSG) and an inverter in a hybrid electric vehicle (HEV). In an HEV, there are a number of components, including the combustion engine, transmission, traction motor, motor controller, OBC, and HSG system. The proposed design reconfigures the HSG system to provide battery-charging capability instead of a conventional OBC based on the use of additional power relays. As a result, the number of power converters is effectively reduced through the replacement of the conventional OBC, and, thus, the power density is increased. This paper also proposes a control method for enabling not only battery charging but also a reactive power support depending on the grid command. Compared with a conventional reactive power compensation method, the proposed method has an advantage because it is located near the principal reactive power source. The simulation and experimental results verify the validity and feasibility of the proposed bidirectional OBC design and its control methods.
- 1 November 2018
- Published by MDPI AG in Electronics
- Vol. 7 (11) , 287
Open AccessSingle-Phase Bidirectional On-Board Charger Using Starter Generator System in Hybrid Electric Vehicles
This paper presents the design and control methods of a single-phase bidirectional on-board charger (OBC) using a hybrid starter generator (HSG) and an inverter in a hybrid electric vehicle (HEV). In an HEV, there are a number of components, including the combustion engine, transmission, traction motor, motor controller, OBC, and HSG system. The proposed design reconfigures the HSG system to provide battery-charging capability instead of a conventional OBC based on the use of additional power relays. As a result, the number of power converters is effectively reduced through the replacement of the conventional OBC, and, thus, the power density is increased. This paper also proposes a control method for enabling not only battery charging but also a reactive power support depending on the grid command. Compared with a conventional reactive power compensation method, the proposed method has an advantage because it is located near the principal reactive power source. The simulation and experimental results verify the validity and feasibility of the proposed bidirectional OBC design and its control methods.