Hydrodynamic and Longitudinal Impedance Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction in Type I Chiari Malformation
Authors:
Open Access
- 10 October 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (10) , e75335
Abstract
Elevated or reduced velocity of cerebrospinal fluid (CSF) at the craniovertebral junction (CVJ) has been associated with type I Chiari malformation (CMI). Thus, quantification of hydrodynamic parameters that describe the CSF dynamics could help assess disease severity and surgical outcome. In this study, we describe the methodology to quantify CSF hydrodynamic parameters near the CVJ and upper cervical spine utilizing subject-specific computational fluid dynamics (CFD) simulations based on in vivo MRI measurements of flow and geometry. Hydrodynamic parameters were computed for a healthy subject and two CMI patients both pre- and post-decompression surgery to determine the differences between cases. For the first time, we present the methods to quantify longitudinal impedance (LI) to CSF motion, a subject-specific hydrodynamic parameter that may have value to help quantify the CSF flow blockage severity in CMI. In addition, the following hydrodynamic parameters were quantified for each case: maximum velocity in systole and diastole, Reynolds and Womersley number, and peak pressure drop during the CSF cardiac flow cycle. The following geometric parameters were quantified: cross-sectional area and hydraulic diameter of the spinal subarachnoid space (SAS). The mean values of the geometric parameters increased post-surgically for the CMI models, but remained smaller than the healthy volunteer. All hydrodynamic parameters, except pressure drop, decreased post-surgically for the CMI patients, but remained greater than in the healthy case. Peak pressure drop alterations were mixed. To our knowledge this study represents the first subject-specific CFD simulation of CMI decompression surgery and quantification of LI in the CSF space. Further study in a larger patient and control group is needed to determine if the presented geometric and/or hydrodynamic parameters are helpful for surgical planning.Keywords
This publication has 35 references indexed in Scilit:
- Comparison of 4D Phase-Contrast MRI Flow Measurements to Computational Fluid Dynamics Simulations of Cerebrospinal Fluid Motion in the Cervical SpinePLOS ONE, 2012
- Impact of Aortic Grafts on Arterial Pressure: A Computational Fluid Dynamics StudyEuropean Journal of Vascular and Endovascular Surgery, 2011
- Effect of Tonsillar Herniation on Cyclic CSF Flow Studied with Computational Flow AnalysisAmerican Journal of Neuroradiology, 2011
- Morphometric Analysis of the Foramen MagnumNeurosurgery, 2010
- Motion of the Cerebellar Tonsils in the Foramen Magnum during the Cardiac CycleAmerican Journal of Neuroradiology, 2009
- Chiari malformation: CSF flow dynamics in the craniocervical junction and syrinxActa Neurochirurgica, 2005
- Magnetic resonance imaging—based measurements of cerebrospinal fluid and blood flow as indicators of intracranial compliance in patients with Chiari malformationJournal of Neurosurgery, 2005
- Foramen magnum cerebrospinal fluid flow characteristics in children with Chiari I malformation before and after craniocervical decompressionJournal of neurosurgery. Pediatrics, 2004
- Relationship Between Preoperative Duplex Vein Mapping and Intraoperative Longitudinal Impedance in Infrainguinal Vein GraftsVascular Surgery, 2000
- The Effect of «Non-critical» (<50%) Stenosis on Vein Graft Longitudinal Resistance and ImpedanceEuropean Journal of Vascular and Endovascular Surgery, 1999