Abstract
The insulators of the catenary of the Lanzhou-Xinjiang High-speed Railway in windy areas suffer from serious contamination, which has led to frequent flashover accidents. The catenary of the Lanzhou-Xinjiang High-speed Railway has adopted the unique external insulation of V-type double suspension rod insulators. To further determine the contamination characteristics of this type of insulator, a contamination simulation model of insulator is established in this paper based on the principles of fluid mechanics, which is used to analyze the contamination characteristics of the V-type double suspension rod insulators under the influence of wake flow. The research results show that wind speed directly determines the static pressure on the surface of the insulator, the wind speed and particle concentration are proportional to the contamination volumes on the windward and crosswind sides of insulator, while the particle size is inversely proportional to the contamination volume on the leeward side of the insulator. The direction of wake flow is consistent with the direction angle of external incoming flow, and the wake flow generating area affects the contamination characteristics of the insulator. When the incoming flow is at a prevailing wind direction of 0°, focus should be put on the windward and crosswind sides of the two insulators during insulator cleaning, and the contamination distributions on these two insulators are similar; when the incoming flow is at a prevailing wind elevation of 0∼60, focus should be put on the entire surface of 1# insulator and the windward and crosswind sides of 2# insulator during insulator cleaning.
Keywords
Funding Information
- National Natural Science Foundation of China (51867013, 51767014, 51567014, TY202010)
- Tianyou innovation team plan of Lanzhou Jiaotong University (51867013, 51767014, 51567014, TY202010)
This publication has 22 references indexed in Scilit:
- Study on the difference of chemical composition of insulator contamination on UHV‐AC and ‐DC transmission linesIET Science, Measurement & Technology, 2018
- Experimental study on the contamination deposition characteristics of insulators in a fog–haze environmentIET Generation, Transmission & Distribution, 2017
- The Movement Characteristics of Charged Haze Particles in Ionized Field and Its Influence on Contamination of InsulatorIEEE Transactions on Magnetics, 2017
- Pollution accumulation characteristics of insulators under natural rainfallIET Generation, Transmission & Distribution, 2017
- Source strength impact analysis on polymer insulator flashover under contaminated conditions and a comparison with porcelainIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Simulation study on pollution accumulation characteristics of XP13-160 porcelain suspension disc insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- A probabilistic model for insulator flashover under contaminated conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Suspension flow past a cylinder: particle interactions with recirculating wakesJournal of Fluid Mechanics, 2014
- Prediction of flashover voltage of insulators using least squares support vector machinesExpert Systems with Applications, 2009
- Design of an artificial neural network for the estimation of the flashover voltage on insulatorsElectric Power Systems Research, 2007