Shanpeng Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shanpeng Zhao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Youpeng Zhang
China Railway Beijing Group Co., Ltd., Beijing 100038, China
4 shared publications - Chenrui Zhang
School of Automation & Electrical Engineering, Lanzhou Jiaotong University, Anning District, Lanzhou 730070, China
2 shared publications - Huayu Yuan
School of Electronic & Information Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
2 shared publications Shaoxiang Zhao
School of Automation & Electrical Engineering Lanzhou Jiaotong University Lanzhou 730070 China
2 shared publicationsYoupeng Zhang
2 shared publications- Youpeng Zhang
School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
2 shared publications
Latest Publications
- Open Access
Deep Learning-Based Instance Segmentation of Galloping High-Speed Railway Overhead Contact System Conductors in Video Images
The conductors of high-speed railway OCSs (Overhead Contact Systems) are susceptible to conductor galloping due to the impact of natural elements such as strong winds, rain, and snow, resulting in conductor fatigue damage and significantly compromising train operational safety. Consequently, monitoring the galloping status of conductors is crucial, and instance segmentation techniques, by delineating the pixel-level contours of each conductor, can significantly aid in the identification and study of galloping phenomena. This work expands upon the YOLO11-seg model and introduces an instance segmentation approach for galloping video and image sensor data of OCS conductors. The algorithm, designed for the stripe-like distribution of OCS conductors in the data, employs four-direction Sobel filters to extract edge features in horizontal, vertical, and diagonal orientations. These features are subsequently integrated with the original convolutional branch to form the FDSE (Four Direction Sobel Enhancement) module. It integrates the ECA (Efficient Channel Attention) mechanism for the adaptive augmentation of conductor characteristics and utilizes the FL (Focal Loss) function to mitigate the class-imbalance issue between positive and negative samples, hence enhancing the model’s sensitivity to conductors. Consequently, segmentation outcomes from neighboring frames are utilized, and mask-difference analysis is performed to autonomously detect conductor galloping locations, emphasizing their contours for the clear depiction of galloping characteristics. Experimental results demonstrate that the enhanced YOLO11-seg model achieves 85.38% precision, 77.30% recall, 84.25% AP@0.5, 81.14% F1-score, and a real-time processing speed of 44.78 FPS. When combined with the galloping visualization module, it can issue real-time alerts of conductor galloping anomalies, providing robust technical support for railway OCS safety monitoring.
Open AccessDeep Learning-Based Instance Segmentation of Galloping High-Speed Railway Overhead Contact System Conductors in Video Images
The conductors of high-speed railway OCSs (Overhead Contact Systems) are susceptible to conductor galloping due to the impact of natural elements such as strong winds, rain, and snow, resulting in conductor fatigue damage and significantly compromising train operational safety. Consequently, monitoring the galloping status of conductors is crucial, and instance segmentation techniques, by delineating the pixel-level contours of each conductor, can significantly aid in the identification and study of galloping phenomena. This work expands upon the YOLO11-seg model and introduces an instance segmentation approach for galloping video and image sensor data of OCS conductors. The algorithm, designed for the stripe-like distribution of OCS conductors in the data, employs four-direction Sobel filters to extract edge features in horizontal, vertical, and diagonal orientations. These features are subsequently integrated with the original convolutional branch to form the FDSE (Four Direction Sobel Enhancement) module. It integrates the ECA (Efficient Channel Attention) mechanism for the adaptive augmentation of conductor characteristics and utilizes the FL (Focal Loss) function to mitigate the class-imbalance issue between positive and negative samples, hence enhancing the model’s sensitivity to conductors. Consequently, segmentation outcomes from neighboring frames are utilized, and mask-difference analysis is performed to autonomously detect conductor galloping locations, emphasizing their contours for the clear depiction of galloping characteristics. Experimental results demonstrate that the enhanced YOLO11-seg model achieves 85.38% precision, 77.30% recall, 84.25% AP@0.5, 81.14% F1-score, and a real-time processing speed of 44.78 FPS. When combined with the galloping visualization module, it can issue real-time alerts of conductor galloping anomalies, providing robust technical support for railway OCS safety monitoring.
- Open Access
Research on Video Monitoring Technology for Galloping of OCS Additional Conductors of High-Speed Railway in Strong Wind Zone
The strong wind environment causes the additional conductor of the overhead contact system (OCS) of the Lanzhou–Xinjiang high-speed railway to gallop, significantly impacting the safe operation of the train. This paper presents the design of an online monitoring system for the galloping of additional conductors in the OCS, utilizing video monitoring for accurate and real-time assessment. Initially, the dynamics of the OCS additional conductor and its operational environment are examined, leading to the selection of suitable data transmission and power supply methods to finalize the camera configuration. Secondly, a preprocessing method for enhancing images of galloping in OCS additional conductors is developed, effectively reducing noise in edge detection through a region chain code clustering analysis. The video monitoring system effectively extracts wire edges, addressing the issues of splitting, breakage, and edge overlap in edge detection, while accurately identifying wire targets in video images. In conclusion, a galloping monitoring test platform is established to extract galloping data from additional conductors through video monitoring. The analysis of the galloping frequency and amplitude facilitates the comprehensive monitoring and assessment of the galloping status of OCS additional conductors. The video monitoring system effectively extracts and analyzes galloping data of the OCS additional conductor, fulfilling the fundamental requirements for the online monitoring of additional conductor galloping, and possesses significant engineering application value.
Open AccessResearch on Video Monitoring Technology for Galloping of OCS Additional Conductors of High-Speed Railway in Strong Wind Zone
The strong wind environment causes the additional conductor of the overhead contact system (OCS) of the Lanzhou–Xinjiang high-speed railway to gallop, significantly impacting the safe operation of the train. This paper presents the design of an online monitoring system for the galloping of additional conductors in the OCS, utilizing video monitoring for accurate and real-time assessment. Initially, the dynamics of the OCS additional conductor and its operational environment are examined, leading to the selection of suitable data transmission and power supply methods to finalize the camera configuration. Secondly, a preprocessing method for enhancing images of galloping in OCS additional conductors is developed, effectively reducing noise in edge detection through a region chain code clustering analysis. The video monitoring system effectively extracts wire edges, addressing the issues of splitting, breakage, and edge overlap in edge detection, while accurately identifying wire targets in video images. In conclusion, a galloping monitoring test platform is established to extract galloping data from additional conductors through video monitoring. The analysis of the galloping frequency and amplitude facilitates the comprehensive monitoring and assessment of the galloping status of OCS additional conductors. The video monitoring system effectively extracts and analyzes galloping data of the OCS additional conductor, fulfilling the fundamental requirements for the online monitoring of additional conductor galloping, and possesses significant engineering application value.
- Open Access
- 25 November 2022
- Published by Elsevier in Energy Reports
- Vol. 9, 972-979
Simulation study on the electric field characteristics of ice-covered insulator for catenary positive feeder
- 25 November 2022
- Published by Elsevier in Energy Reports
- Vol. 9, 972-979
Open AccessSimulation study on the electric field characteristics of ice-covered insulator for catenary positive feeder
- Open Access
Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow
The insulators of the catenary of the Lanzhou-Xinjiang High-speed Railway in windy areas suffer from serious contamination, which has led to frequent flashover accidents. The catenary of the Lanzhou-Xinjiang High-speed Railway has adopted the unique external insulation of V-type double suspension rod insulators. To further determine the contamination characteristics of this type of insulator, a contamination simulation model of insulator is established in this paper based on the principles of fluid mechanics, which is used to analyze the contamination characteristics of the V-type double suspension rod insulators under the influence of wake flow. The research results show that wind speed directly determines the static pressure on the surface of the insulator, the wind speed and particle concentration are proportional to the contamination volumes on the windward and crosswind sides of insulator, while the particle size is inversely proportional to the contamination volume on the leeward side of the insulator. The direction of wake flow is consistent with the direction angle of external incoming flow, and the wake flow generating area affects the contamination characteristics of the insulator. When the incoming flow is at a prevailing wind direction of 0°, focus should be put on the windward and crosswind sides of the two insulators during insulator cleaning, and the contamination distributions on these two insulators are similar; when the incoming flow is at a prevailing wind elevation of 0∼60, focus should be put on the entire surface of 1# insulator and the windward and crosswind sides of 2# insulator during insulator cleaning.Open AccessStudy on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow
The insulators of the catenary of the Lanzhou-Xinjiang High-speed Railway in windy areas suffer from serious contamination, which has led to frequent flashover accidents. The catenary of the Lanzhou-Xinjiang High-speed Railway has adopted the unique external insulation of V-type double suspension rod insulators. To further determine the contamination characteristics of this type of insulator, a contamination simulation model of insulator is established in this paper based on the principles of fluid mechanics, which is used to analyze the contamination characteristics of the V-type double suspension rod insulators under the influence of wake flow. The research results show that wind speed directly determines the static pressure on the surface of the insulator, the wind speed and particle concentration are proportional to the contamination volumes on the windward and crosswind sides of insulator, while the particle size is inversely proportional to the contamination volume on the leeward side of the insulator. The direction of wake flow is consistent with the direction angle of external incoming flow, and the wake flow generating area affects the contamination characteristics of the insulator. When the incoming flow is at a prevailing wind direction of 0°, focus should be put on the windward and crosswind sides of the two insulators during insulator cleaning, and the contamination distributions on these two insulators are similar; when the incoming flow is at a prevailing wind elevation of 0∼60, focus should be put on the entire surface of 1# insulator and the windward and crosswind sides of 2# insulator during insulator cleaning. - 29 June 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (9) , 1248-1259
Design and Data Processing of Galloping Online Monitoring System for Positive Feeder of High‐Speed Railway Catenary in Gale Area
To monitor the galloping state of the catenary positive feeder of the Lanzhou–Urumqi high‐speed railway in the gale area, on the basis of previous research results, an online multi‐point distributed galloping monitoring system based on wireless sensor network (WSN) was designed, and the author improves the design of each part of the catenary positive feeder galloping monitoring system to enhance its availability and reliability. By the system to collect accelerations of each galloping monitoring point, and the displacement is obtained by integrating the acceleration twice, but the integration result was seriously distorted because of the trends. A localization algorithm is proposed to correct the galloping signal waveform. Firstly, in accordance with a detailed analysis of ensemble empirical mode decomposition (EEMD) anti‐modal aliasing principle and the steps of the waveform correction method, the original signal was decomposed to obtain ten intrinsic modal functions (IMFs). Secondly, with the IMFs' characteristics as basis, a new method of trend extraction was introduced to extract and eliminate the trends in the original signal. Finally, through the analysis of the measured signal of wire galloping, the feasibility and effectiveness of the proposed method were verified by comparing its results with those of the moving average method, and the galloping trajectory of the wire is obtained by curve fitting. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 29 June 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (9) , 1248-1259
Design and Data Processing of Galloping Online Monitoring System for Positive Feeder of High‐Speed Railway Catenary in Gale Area
To monitor the galloping state of the catenary positive feeder of the Lanzhou–Urumqi high‐speed railway in the gale area, on the basis of previous research results, an online multi‐point distributed galloping monitoring system based on wireless sensor network (WSN) was designed, and the author improves the design of each part of the catenary positive feeder galloping monitoring system to enhance its availability and reliability. By the system to collect accelerations of each galloping monitoring point, and the displacement is obtained by integrating the acceleration twice, but the integration result was seriously distorted because of the trends. A localization algorithm is proposed to correct the galloping signal waveform. Firstly, in accordance with a detailed analysis of ensemble empirical mode decomposition (EEMD) anti‐modal aliasing principle and the steps of the waveform correction method, the original signal was decomposed to obtain ten intrinsic modal functions (IMFs). Secondly, with the IMFs' characteristics as basis, a new method of trend extraction was introduced to extract and eliminate the trends in the original signal. Finally, through the analysis of the measured signal of wire galloping, the feasibility and effectiveness of the proposed method were verified by comparing its results with those of the moving average method, and the galloping trajectory of the wire is obtained by curve fitting. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- Open Access
Collision Mechanism and Deposition Characteristics of Particles on the Catenary Insulator Surface
To solve the problem of contamination flashover of a catenary insulator in an electrified railway, the collision mechanism and deposition characteristics of contamination particles on the insulator surface should be studied to ensure the safe operation of traction power supply systems. This research used horizontal and oblique cantilever insulators as objects, and established the collision model between particles and insulator surface under different arrangements. The deposition conditions of particles on the insulator surface were obtained, and the simulation model of insulator contamination accumulation was established by using the Euler two-phase flow. The difference of contamination deposition characteristics between horizontal and oblique cantilever insulators was analyzed with the volume fraction of contamination particles as the characterization parameter. By comparing the cantilever insulator with the positive feeder insulator, this study analyzed the influence of shed structure on the contamination deposition characteristics. Results show that the installation method of an insulator has an impact on the contamination deposition on the insulator surface. When particle size and wind velocity are fixed, the degree of contamination accumulation on the surface of the oblique cantilever insulator is constantly higher than that of the horizontal cantilever insulator. The insulator shed structure also has a certain effect on the contamination deposition on the insulator surface. For the cantilever insulator, the degree of contamination accumulation of the windward side is higher than that of the leeward side. However, for the positive feeder insulator, the degree of contamination accumulation of the windward side is consistently less than that of the leeward side. Measures to deal with contamination flashover of catenary insulator are proposed.
Open AccessCollision Mechanism and Deposition Characteristics of Particles on the Catenary Insulator Surface
To solve the problem of contamination flashover of a catenary insulator in an electrified railway, the collision mechanism and deposition characteristics of contamination particles on the insulator surface should be studied to ensure the safe operation of traction power supply systems. This research used horizontal and oblique cantilever insulators as objects, and established the collision model between particles and insulator surface under different arrangements. The deposition conditions of particles on the insulator surface were obtained, and the simulation model of insulator contamination accumulation was established by using the Euler two-phase flow. The difference of contamination deposition characteristics between horizontal and oblique cantilever insulators was analyzed with the volume fraction of contamination particles as the characterization parameter. By comparing the cantilever insulator with the positive feeder insulator, this study analyzed the influence of shed structure on the contamination deposition characteristics. Results show that the installation method of an insulator has an impact on the contamination deposition on the insulator surface. When particle size and wind velocity are fixed, the degree of contamination accumulation on the surface of the oblique cantilever insulator is constantly higher than that of the horizontal cantilever insulator. The insulator shed structure also has a certain effect on the contamination deposition on the insulator surface. For the cantilever insulator, the degree of contamination accumulation of the windward side is higher than that of the leeward side. However, for the positive feeder insulator, the degree of contamination accumulation of the windward side is consistently less than that of the leeward side. Measures to deal with contamination flashover of catenary insulator are proposed.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 36, 1084-1090
Study on Pre-warning Model of Railway Signal System with Fuzzy Analytic Hierarchy Process
In order to ensure the safety of high-speed railway transportation, the command role of railway signal system should be brought into full play. By comprehensively analyzing the safety characteristics of railway signal system, a safety railway signal system pre-warning model based on fuzzy analytic hierarchy process (FAHP) was proposed. Firstly, this paper introduced the theory basis of fuzzy comprehensive evaluation method and analytic hierarchy process. Then analysed the natural geological factors, personnel factors, equipment factors and management factors of railway signal system, and studied the safety problems of “human-machine-environment” system. Finally, the feasibility and validity of the model were verified by model analysis. This pre-warning model is applied to the high-speed railway signal system, and has good reliability, high safety. It can not only discover the risk sources and hidden dangers of the railway signal system in time, but also effectively prevent accidents. It has great practical significance to guarantee the safety of railway transportation.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 36, 1084-1090
Study on Pre-warning Model of Railway Signal System with Fuzzy Analytic Hierarchy Process
In order to ensure the safety of high-speed railway transportation, the command role of railway signal system should be brought into full play. By comprehensively analyzing the safety characteristics of railway signal system, a safety railway signal system pre-warning model based on fuzzy analytic hierarchy process (FAHP) was proposed. Firstly, this paper introduced the theory basis of fuzzy comprehensive evaluation method and analytic hierarchy process. Then analysed the natural geological factors, personnel factors, equipment factors and management factors of railway signal system, and studied the safety problems of “human-machine-environment” system. Finally, the feasibility and validity of the model were verified by model analysis. This pre-warning model is applied to the high-speed railway signal system, and has good reliability, high safety. It can not only discover the risk sources and hidden dangers of the railway signal system in time, but also effectively prevent accidents. It has great practical significance to guarantee the safety of railway transportation.
- Open Access
Influence of Partial Arc on Electric Field Distribution of Insulator Strings for Electrified Railway Catenary
The occurrence of a partial arc can affect insulation properties of the insulator by different types of flashover. In order to investigate the influence of a partial arc on electric field distribution along the catenary insulator string, a three-dimensional model of the cap-pin insulator string with partial arc was established in this paper. The electric field distribution along the insulator string when the arc extended on the insulator surface and bridged sheds was investigated based on the electric field analysis using the finite element method. The results showed that the occurrence of a partial arc caused obvious distortion of the electric field, which was a two-dimensional axis symmetrical field before arcing to a three-dimensional field. In the case of arc extension, the sudden rise of field intensity was mostly at the rib and the shed edge, which had the local maximum field intensity. The rib and the shed edge played a certain hindrance role in the extension of the arc. The main reason for promoting the development of the arc can be attributed to thermal ionization. In the case of arc bridge sheds, the highest field intensity appeared at the edge of the last bridged shed. As the number of sheds arc-bridged increased, the maximum field intensity also increased. As the arc length increased, the electric field intensity of the arc head also increased, which resulted in an accelerated arc development. The main factor to promote the development of the arc can be attributed to electrical breakdown. The measures to hinder the rapid development of partial arcs were proposed.
Open AccessInfluence of Partial Arc on Electric Field Distribution of Insulator Strings for Electrified Railway Catenary
The occurrence of a partial arc can affect insulation properties of the insulator by different types of flashover. In order to investigate the influence of a partial arc on electric field distribution along the catenary insulator string, a three-dimensional model of the cap-pin insulator string with partial arc was established in this paper. The electric field distribution along the insulator string when the arc extended on the insulator surface and bridged sheds was investigated based on the electric field analysis using the finite element method. The results showed that the occurrence of a partial arc caused obvious distortion of the electric field, which was a two-dimensional axis symmetrical field before arcing to a three-dimensional field. In the case of arc extension, the sudden rise of field intensity was mostly at the rib and the shed edge, which had the local maximum field intensity. The rib and the shed edge played a certain hindrance role in the extension of the arc. The main reason for promoting the development of the arc can be attributed to thermal ionization. In the case of arc bridge sheds, the highest field intensity appeared at the edge of the last bridged shed. As the number of sheds arc-bridged increased, the maximum field intensity also increased. As the arc length increased, the electric field intensity of the arc head also increased, which resulted in an accelerated arc development. The main factor to promote the development of the arc can be attributed to electrical breakdown. The measures to hinder the rapid development of partial arcs were proposed.