Non‐invasive prediction of fluid responsiveness in infants using pleth variability index
Authors:
- 3 May 2011
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 66 (7) , 582-589
Abstract
Summary: This prospective study assessed whether respiratory variations in velocity time integral, peak blood flow velocity and non‐invasive pleth variability index are useful measurements in infants undergoing congenital heart surgery and determined threshold values that may help guide fluid administration. In 27 infants receiving mechanical ventilation, of mean (SD) weight 10.4 (6.3) kg, 13 increased their stroke volume index ≥ 15% following a fluid challenge and 14 did not. The best area under the receiver operating characteristic curve was for the echocardiographic‐derived variables respiratory variation in blood peak flow velocity (area under the ROC curve = 0.92; p = 0.0002) and respiratory variation of the velocity time integral (area under the ROC curve = 0.84; p = 0.002). The pleth variability index also predicted fluid responsiveness (area under the ROC curve = 0.79; p = 0.01), in contrast to heart rate (area under the ROC curve = 0.53; p = 0.75) and central venous pressure (area under the ROC curve = 0.57; p = 0.52).Keywords
This publication has 31 references indexed in Scilit:
- The Ability of a Novel Algorithm for Automatic Estimation of the Respiratory Variations in Arterial Pulse Pressure to Monitor Fluid Responsiveness in the Operating RoomAnesthesia & Analgesia, 2008
- Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated childrenIntensive Care Medicine, 2008
- Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal modelActa Anaesthesiologica Scandinavica, 2008
- Fluid responsiveness using non-invasive predictors during major hepatic surgeryBritish Journal of Anaesthesia, 2007
- Stroke Volume and Pulse Pressure Variation for Prediction of Fluid Responsiveness in Patients Under oing Off-Pump Coronary Artery Bypass GraftingChest, 2005
- Changes in Arterial Pressure during Mechanical VentilationAnesthesiology, 2005
- Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjectsCritical Care Medicine, 2004
- Predicting Fluid Responsiveness in ICU PatientsChest, 2002
- Respiratory Changes in Aortic Blood Velocity as an Indicator of Fluid Responsiveness in Ventilated Patients With Septic ShockChest, 2001
- Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: Derivation of cardiac outputCritical Care Medicine, 2000