Sensitivity Analysis of a 6 MeV Photon Beam Monte Carlo Model
Authors:
Open Access
- 29 May 2023
- journal article
- research article
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 13 (2) , 144-152
Abstract
Background: This study aimed to optimize efficiency in Monte Carlo (MC) simulation using sensitivity analysis of a beam model. Methods: The BEAMnrc-based model of 6 MV beam of a Siemens Primus linac was developed. For sensitivity analysis, the effect of the electron source, treatment head, and virtual phantom specifications on calculated percent depth dose (PDD) and lateral dose profiles was evaluated. Results: The optimum mean energy (E) and the full width at half maximum (FWHM) of the intensity distribution of the electron beam were calculated as 6.7 MeV and 3 mm, respectively. Increasing E from 6.1 to 6.7 MeV, increased the PDD in the fall-off region by 4.70% and decreased the lateral profile by 8.76%. Changing the FWHM had a significant effect on the buildup region of PDD and the horns and out-of-field regions of the lateral profile. Increasing the collimators opening by 0.5 mm, PDD increased by 2.13% and the central and penumbra regions of profiles decreased by 1.98% and 11.40% respectively. Collimator properties such as thickness and density were effective in changing the penumbra (11.32% for 0.25 cm increment) and the out-of-field (22.82% for 3 g/cm3) regions of the lateral profiles. Conclusion: Analysis of a 6 MV model showed that PDD profiles were more sensitive to changes in energy than to FWHM of the electron source. The lateral profiles were sensitive to E, FWHM, and collimator opening. The density of the collimator affected only the out-of-field region of lateral profiles. The findings of this study may be used to make benchmarking of an MC beam model more efficient.Keywords
This publication has 19 references indexed in Scilit:
- Validation of BEAMnrc Monte Carlo model for a 12 MV photon beamJournal of King Saud University – Science, 2018
- Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmarkPhysics in Medicine & Biology, 2015
- Determining optimization of the initial parameters in Monte Carlo simulation for linear accelerator radiotherapyRadiation Physics and Chemistry, 2013
- Monte Carlo study of in‐field and out‐of‐field dose distributions from a linear accelerator operating with and without a flattening‐filterMedical Physics, 2012
- Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrcMedical Physics, 2006
- Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beamsMedical Physics, 2004
- Determining the incident electron fluence for Monte Carlo‐based photon treatment planning using a standard measured data setMedical Physics, 2003
- Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parametersMedical Physics, 2002
- Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM codeMedical Physics, 2002
- Comparison of measured and Monte Carlo calculated dose distributions from the NRC linacMedical Physics, 2000