On the Optimum Utilization of Water Hammer
Authors:
- 1 November 1988
- journal article
- review article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Power and Process Engineering
- Vol. 202 (4) , 249-256
Abstract
The computerized method of characteristics was used to analyse, for a single pipeline discharging into the atmosphere, the effects of valve-closure schedule and pipe length on optimum water-hammer strength. It was found that the criteria of optimum water-hammer utilization are a non-linear inherent valve schedule in which the bulk of the pressure surge occurs near the beginning or towards the end of valve closure, together with as small a value of dimensionless valve-closure time and as high a value of wide-open valve area as is consistent with cavitation-free operation. Also, a comparison of the results with hydraulic ram test data suggests that optimum drive pipe length may be based solely on optimum water-hammer strength, in the light of the relative effects of pipe friction and dimensionless valve-closure time. In general, optimum pipe length is not highly sensitive to inherent valve-closure schedule, water-hammer strength, pipe size or reservoir head.Keywords
This publication has 3 references indexed in Scilit:
- Effect of Valve‐Closure Schedule on Water HammerJournal of Hydraulic Engineering, 1986
- An Introduction to the Dynamic Pressure ExchangerProceedings of the Institution of Mechanical Engineers, 1965
- The Automatic Hydraulic RamProceedings of the Institution of Mechanical Engineers, 1951