Abstract
Simultaneous quantification of two contrast agents in dual-energy CT (DECT) is promising for clinical diagnostics. This simulation study demonstrates that accurate estimation of iodine and gadolinium concentrations in unmixed aqueous solutions can be achieved using two-material decomposition and beam-hardening suppression with the dual-energy iterative reconstruction algorithm (DIRA). A simulated DECT imaging chain was used for evaluation. The phantom comprised a lipid cylinder containing five inserts filled with water, iodine (25 and 50 mg/mL), and gadolinium (25 and 50 mg/mL) solutions. X-ray projections at 80 and Sn140 kV were generated using Siemens’ DRASIM code. DIRA was configured for two-material decomposition with water–bone, water–iodine, and water–gadolinium bases, and cylinder positions were manually defined during reconstruction. After approximately six iterations, accurate estimates of contrast agent mass fractions were obtained. These results confirm the feasibility of simultaneous iodine and gadolinium quantification in DECT and support further development toward a clinical application.Keywords
Funding Information
- Cancerfonden (CAN 2017/1029)
- Cancerfonden (CAN 2018/622)
- ALF Grants Region Östergötland (LiO-602731)
- Patientsäkerhetsforskning Region Östergötland (LiO-724181)
- Vetenskapsrådet (VR-NT 2016-05033)
This publication has 17 references indexed in Scilit:
- No gadolinium K‐edge detected on the first clinical photon‐counting computed tomography scannerJournal of Applied Clinical Medical Physics, 2024
- On the Choice of Base Materials for Alvarez–Macovski and DIRA Dual-energy Reconstruction Algorithms in CT2023
- Bicolor K-edge spectral photon-counting CT imaging for the diagnosis of thoracic endoleaks: A dynamic phantom studyDiagnostic and Interventional Imaging, 2023
- ACCURACY OF CT NUMBERS OBTAINED BY DIRA AND MONOENERGETIC PLUS ALGORITHMS IN DUAL-ENERGY COMPUTED TOMOGRAPHYRadiation Protection Dosimetry, 2021
- OPTIMAL SELECTION OF BASE MATERIALS FOR ACCURATE DUAL-ENERGY COMPUTED TOMOGRAPHY: COMPARISON BETWEEN THE ALVAREZ–MACOVSKI METHOD AND DIRARadiation Protection Dosimetry, 2021
- DIRA-3D—a model-based iterative algorithm for accurate dual-energy dual-source 3D helical CTBiomedical Physics & Engineering Express, 2019
- A model-based iterative reconstruction algorithm DIRA using patient-specific tissue classification via DECT for improved quantitative CT in dose planningMedical Physics, 2017
- Clinical Implementation of Dual-energy CT for Proton Treatment Planning on Pseudo-monoenergetic CT scansInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2017
- Nanoparticle contrast agents for computed tomography: a focus on micellesContrast Media & Molecular Imaging, 2014
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976