Alexandr Malusek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexandr Malusek has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Michael Sandborg
Department of Health, Medicine and Caring Sciences, Linköping University , SE-581 83 Linköping
6 shared publications - Maria Magnusson
Department of Electrical Engineering, Linköping University , SE-581 83 Linköping
5 shared publications Åsa Carlsson Tedgren
Center for Medical Image Science and Visualization (CMIV), Linköping University , SE-581 85 Linköping
4 shared publications- Åsa Carlsson Tedgren
Radiation Physics Department IMH, Linkoping University Department of Medical and Health Sciences, S-581 85 Linkoping, Linkoping, 581 83, SWEDEN
4 shared publications G. Alm Carlsson
Medical Radiation Physics, Department of Medical and Health Sciences and Center for Medical Image Science and Visualisation, Linköping University, Linköping SE 58185, Sweden
3 shared publicationsM. Sandborg
Medical Radiation Physics, Department of Medical and Health Sciences and Center for Medical Image Science and Visualisation, Linköping University, Linköping SE 58185, Sweden
3 shared publications
Latest Publications
- Open Access
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 172-179
Optimizing material composition determination in dual-energy computed tomography: a comparative study of a linear model and a fully connected neural network
Accurate elemental decomposition in dual-energy computed tomography (DECT) is crucial for precision in radiation therapy planning. We present a comparative study of linear regression and fully connected neural networks (FCNNs) for voxel-wise prediction of tissue elemental composition, using synthetic datasets that incorporate realistic intra- and inter-patient variability. Both models performed well under noise-free conditions, with linear regression yielding slightly lower errors. Under noisy conditions, performance degraded for both models, though the linear model generally retained lower numerical error. The FCNNs, however, consistently produced physically plausible (non-negative) elemental mass-fraction estimates. These models are well suited for integration into model-based iterative reconstruction algorithms to support artificial intelligence-driven radiation treatment planning. Future work should incorporate elemental covariances and spatial context to enhance accuracy and clinical utility.
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 172-179
Open AccessOptimizing material composition determination in dual-energy computed tomography: a comparative study of a linear model and a fully connected neural network
Accurate elemental decomposition in dual-energy computed tomography (DECT) is crucial for precision in radiation therapy planning. We present a comparative study of linear regression and fully connected neural networks (FCNNs) for voxel-wise prediction of tissue elemental composition, using synthetic datasets that incorporate realistic intra- and inter-patient variability. Both models performed well under noise-free conditions, with linear regression yielding slightly lower errors. Under noisy conditions, performance degraded for both models, though the linear model generally retained lower numerical error. The FCNNs, however, consistently produced physically plausible (non-negative) elemental mass-fraction estimates. These models are well suited for integration into model-based iterative reconstruction algorithms to support artificial intelligence-driven radiation treatment planning. Future work should incorporate elemental covariances and spatial context to enhance accuracy and clinical utility.
- Open Access
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 268-275
Quantitative determination of gadolinium and iodine contrast agents in dual-energy computed tomography via a dual-energy iterative reconstruction algorithm: a simulation study on multi-contrast imaging
Simultaneous quantification of two contrast agents in dual-energy CT (DECT) is promising for clinical diagnostics. This simulation study demonstrates that accurate estimation of iodine and gadolinium concentrations in unmixed aqueous solutions can be achieved using two-material decomposition and beam-hardening suppression with the dual-energy iterative reconstruction algorithm (DIRA). A simulated DECT imaging chain was used for evaluation. The phantom comprised a lipid cylinder containing five inserts filled with water, iodine (25 and 50 mg/mL), and gadolinium (25 and 50 mg/mL) solutions. X-ray projections at 80 and Sn140 kV were generated using Siemens’ DRASIM code. DIRA was configured for two-material decomposition with water–bone, water–iodine, and water–gadolinium bases, and cylinder positions were manually defined during reconstruction. After approximately six iterations, accurate estimates of contrast agent mass fractions were obtained. These results confirm the feasibility of simultaneous iodine and gadolinium quantification in DECT and support further development toward a clinical application.
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 268-275
Open AccessQuantitative determination of gadolinium and iodine contrast agents in dual-energy computed tomography via a dual-energy iterative reconstruction algorithm: a simulation study on multi-contrast imaging
Simultaneous quantification of two contrast agents in dual-energy CT (DECT) is promising for clinical diagnostics. This simulation study demonstrates that accurate estimation of iodine and gadolinium concentrations in unmixed aqueous solutions can be achieved using two-material decomposition and beam-hardening suppression with the dual-energy iterative reconstruction algorithm (DIRA). A simulated DECT imaging chain was used for evaluation. The phantom comprised a lipid cylinder containing five inserts filled with water, iodine (25 and 50 mg/mL), and gadolinium (25 and 50 mg/mL) solutions. X-ray projections at 80 and Sn140 kV were generated using Siemens’ DRASIM code. DIRA was configured for two-material decomposition with water–bone, water–iodine, and water–gadolinium bases, and cylinder positions were manually defined during reconstruction. After approximately six iterations, accurate estimates of contrast agent mass fractions were obtained. These results confirm the feasibility of simultaneous iodine and gadolinium quantification in DECT and support further development toward a clinical application.
- Open Access
- 16 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Automated bone property analysis using corrected in vivo dental cone-beam CT data of human wrists
Fracture liaison services are essential to mitigate underdiagnosis and undertreatment of osteoporosis-related fractures. However, it often suffers from limited access to dual-energy X-ray absorptiometry (DXA) or high-resolution peripheral quantitative CT equipment. This in vivo study of 21 patients aims to evaluate the feasibility of dental cone beam CT (dCBCT) to analyse bone properties of human wrists, comparing with DXA and finite element (FE) analysis. dCBCT grey-scale values were transformed to HU using a phantom containing materials with known HU values. Strong correlations were found between bone mineral content (BMC) from dCBCT and DXA (r = 0.78 to 0.84, p < 0.001), as well as between BMC from dCBCT FE-predicted stiffness (r = 0.91) and maximum force (r = 0.93), p < 0.001. BMC values from dCBCT were higher than DXA measurements (2.34 g vs. 1.5 g, p < 0.001). Cortical thickness strongly correlated to bone mineral density (BMD) from dCBCT (r = 0.83, p < 0.001). No statistically significant correlations were found between trabecular bone microstructure and FE predictions. The results indicate the feasibility to analyse osteoporosis related bone properties of human wrists from corrected dCBCT data. The dCBCT values of BMD and BMC were strongly correlated with DXA.
- 16 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessAutomated bone property analysis using corrected in vivo dental cone-beam CT data of human wrists
Fracture liaison services are essential to mitigate underdiagnosis and undertreatment of osteoporosis-related fractures. However, it often suffers from limited access to dual-energy X-ray absorptiometry (DXA) or high-resolution peripheral quantitative CT equipment. This in vivo study of 21 patients aims to evaluate the feasibility of dental cone beam CT (dCBCT) to analyse bone properties of human wrists, comparing with DXA and finite element (FE) analysis. dCBCT grey-scale values were transformed to HU using a phantom containing materials with known HU values. Strong correlations were found between bone mineral content (BMC) from dCBCT and DXA (r = 0.78 to 0.84, p < 0.001), as well as between BMC from dCBCT FE-predicted stiffness (r = 0.91) and maximum force (r = 0.93), p < 0.001. BMC values from dCBCT were higher than DXA measurements (2.34 g vs. 1.5 g, p < 0.001). Cortical thickness strongly correlated to bone mineral density (BMD) from dCBCT (r = 0.83, p < 0.001). No statistically significant correlations were found between trabecular bone microstructure and FE predictions. The results indicate the feasibility to analyse osteoporosis related bone properties of human wrists from corrected dCBCT data. The dCBCT values of BMD and BMC were strongly correlated with DXA.
- Open Access
- 22 September 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 168, 111110
Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
- 22 September 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 168, 111110
Open AccessSpectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
- Open Access
- 16 July 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 212-217
ACCURACY OF CT NUMBERS OBTAINED BY DIRA AND MONOENERGETIC PLUS ALGORITHMS IN DUAL-ENERGY COMPUTED TOMOGRAPHY
Dual-energy computed tomography (CT) can be used in radiotherapy treatment planning for the calculation of absorbed dose distributions. The aim of this work is to evaluate whether there is room for improvement in the accuracy of the Monoenergetic Plus algorithm by Siemens Healthineers. A Siemens SOMATOM Force scanner was used to scan a cylindrical polymethyl methacrylate phantom with four rod-inserts made of different materials. Images were reconstructed using ADMIRE and processed with Monoenergetic Plus. The resulting CT numbers were compared with tabulated values and values simulated by the proof-of-a-concept algorithm DIRA developed by the authors. Both the Monoenergetic Plus and DIRA algorithms performed well; the accuracy of attenuation coefficients was better than about ±1% at the energy of 70 keV. Compared with DIRA, the worse performance of Monoenergetic Plus was caused by its (i) two-material decomposition to iodine and water and (ii) imperfect suppression of the beam hardening artifact in ADMIRE.
- 16 July 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 212-217
Open AccessACCURACY OF CT NUMBERS OBTAINED BY DIRA AND MONOENERGETIC PLUS ALGORITHMS IN DUAL-ENERGY COMPUTED TOMOGRAPHY
Dual-energy computed tomography (CT) can be used in radiotherapy treatment planning for the calculation of absorbed dose distributions. The aim of this work is to evaluate whether there is room for improvement in the accuracy of the Monoenergetic Plus algorithm by Siemens Healthineers. A Siemens SOMATOM Force scanner was used to scan a cylindrical polymethyl methacrylate phantom with four rod-inserts made of different materials. Images were reconstructed using ADMIRE and processed with Monoenergetic Plus. The resulting CT numbers were compared with tabulated values and values simulated by the proof-of-a-concept algorithm DIRA developed by the authors. Both the Monoenergetic Plus and DIRA algorithms performed well; the accuracy of attenuation coefficients was better than about ±1% at the energy of 70 keV. Compared with DIRA, the worse performance of Monoenergetic Plus was caused by its (i) two-material decomposition to iodine and water and (ii) imperfect suppression of the beam hardening artifact in ADMIRE.
- Open Access
- 9 June 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 225-231
ON THE POSSIBILITY TO RESOLVE GADOLINIUM- AND CERIUM-BASED CONTRAST AGENTS FROM THEIR CT NUMBERS IN DUAL-ENERGY COMPUTED TOMOGRAPHY
Cerium oxide nanoparticles with integrated gadolinium have been proved to be useful as contrast agents in magnetic resonance imaging. Of question is their performance in dual-energy computed tomography. The aims of this work are to determine (1) the relation between the computed tomography number and the concentration of the I, Gd or Ce contrast agent and (2) under what conditions it is possible to resolve the type of contrast agent. Hounsfield values of iodoacetic acid, gadolinium acetate and cerium acetate dissolved in water at molar concentrations of 10, 50 and 100 mM were measured in a water phantom using the Siemens SOMATOM Definition Force scanner; gadolinium- and cerium acetate were used as substitutes for the gadolinium-integrated cerium oxide nanoparticles. The relation between the molar concentration of the I, Gd or Ce contrast agent and the Hounsfield value was linear. Concentrations had to be sufficiently high to resolve the contrast agents.
- 9 June 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 225-231
Open AccessON THE POSSIBILITY TO RESOLVE GADOLINIUM- AND CERIUM-BASED CONTRAST AGENTS FROM THEIR CT NUMBERS IN DUAL-ENERGY COMPUTED TOMOGRAPHY
Cerium oxide nanoparticles with integrated gadolinium have been proved to be useful as contrast agents in magnetic resonance imaging. Of question is their performance in dual-energy computed tomography. The aims of this work are to determine (1) the relation between the computed tomography number and the concentration of the I, Gd or Ce contrast agent and (2) under what conditions it is possible to resolve the type of contrast agent. Hounsfield values of iodoacetic acid, gadolinium acetate and cerium acetate dissolved in water at molar concentrations of 10, 50 and 100 mM were measured in a water phantom using the Siemens SOMATOM Definition Force scanner; gadolinium- and cerium acetate were used as substitutes for the gadolinium-integrated cerium oxide nanoparticles. The relation between the molar concentration of the I, Gd or Ce contrast agent and the Hounsfield value was linear. Concentrations had to be sufficiently high to resolve the contrast agents.
- Open Access
- 25 May 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 172-176
SEMI-AUTOMATED 3D SEGMENTATION OF PELVIC REGION BONES IN CT VOLUMES FOR THE ANNOTATION OF MACHINE LEARNING DATASETS
Automatic segmentation of bones in computed tomography (CT) images is used for instance in beam hardening correction algorithms where it improves the accuracy of resulting CT numbers. Of special interest are pelvic bones, which—because of their strong attenuation—affect the accuracy of brachytherapy in this region. This work evaluated the performance of the JJ2016 algorithm with the performance of MK2014v2 and JS2018 algorithms; all these algorithms were developed by authors. Visual comparison, and, in the latter case, also Dice similarity coefficients derived from the ground truth were used. It was found that the 3D-based JJ2016 performed better than the 2D-based MK2014v2, mainly because of the more accurate hole filling that benefitted from information in adjacent slices. The neural network-based JS2018 outperformed both traditional algorithms. It was, however, limited to the resolution of 1283 owing to the limited amount of memory in the graphical processing unit (GPU).
- 25 May 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 172-176
Open AccessSEMI-AUTOMATED 3D SEGMENTATION OF PELVIC REGION BONES IN CT VOLUMES FOR THE ANNOTATION OF MACHINE LEARNING DATASETS
Automatic segmentation of bones in computed tomography (CT) images is used for instance in beam hardening correction algorithms where it improves the accuracy of resulting CT numbers. Of special interest are pelvic bones, which—because of their strong attenuation—affect the accuracy of brachytherapy in this region. This work evaluated the performance of the JJ2016 algorithm with the performance of MK2014v2 and JS2018 algorithms; all these algorithms were developed by authors. Visual comparison, and, in the latter case, also Dice similarity coefficients derived from the ground truth were used. It was found that the 3D-based JJ2016 performed better than the 2D-based MK2014v2, mainly because of the more accurate hole filling that benefitted from information in adjacent slices. The neural network-based JS2018 outperformed both traditional algorithms. It was, however, limited to the resolution of 1283 owing to the limited amount of memory in the graphical processing unit (GPU).
- Open Access
- 1 January 2020
- Published by Elsevier in Physica Medica
- Vol. 69, 241-247
Segmentation of bones in medical dual-energy computed tomography volumes using the 3D U-Net
- 1 January 2020
- Published by Elsevier in Physica Medica
- Vol. 69, 241-247
Open AccessSegmentation of bones in medical dual-energy computed tomography volumes using the 3D U-Net
- Open Access
- 10 September 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (6) , 065005
DIRA-3D—a model-based iterative algorithm for accurate dual-energy dual-source 3D helical CT
Quantitative dual-energy computed tomography may improve the accuracy of treatment planning in radiation therapy. Of special interest are algorithms that can estimate material composition of the imaged object. One example of such an algorithm is the 2D model-based iterative reconstruction algorithm DIRA. The aim of this work is to extend this algorithm to 3D so that it can be used with cone-beams and helical scanning. In the new algorithm, the parallel FBP method was replaced with the approximate 3D FBP-based PI-method. Its performance was tested using a mathematical phantom consisting of six ellipsoids. The algorithm substantially reduced the beam-hardening artefact and the artefacts caused by approximate reconstruction after six iterations. Compared to Alvarez-Macovski’s base material decomposition, DIRA-3D does not require geometrically consistent projections and hence can be used in dual-source CT scanners. Also, it can use several tissue-specific material bases at the same time to represent the imaged object.
- 10 September 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (6) , 065005
Open AccessDIRA-3D—a model-based iterative algorithm for accurate dual-energy dual-source 3D helical CT
Quantitative dual-energy computed tomography may improve the accuracy of treatment planning in radiation therapy. Of special interest are algorithms that can estimate material composition of the imaged object. One example of such an algorithm is the 2D model-based iterative reconstruction algorithm DIRA. The aim of this work is to extend this algorithm to 3D so that it can be used with cone-beams and helical scanning. In the new algorithm, the parallel FBP method was replaced with the approximate 3D FBP-based PI-method. Its performance was tested using a mathematical phantom consisting of six ellipsoids. The algorithm substantially reduced the beam-hardening artefact and the artefacts caused by approximate reconstruction after six iterations. Compared to Alvarez-Macovski’s base material decomposition, DIRA-3D does not require geometrically consistent projections and hence can be used in dual-source CT scanners. Also, it can use several tissue-specific material bases at the same time to represent the imaged object.
- Open Access
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 169
[P244] Accuracy of ct numbers obtained by dira and monoenergetic plus algorithms in quantitative dual-energy computed tomography
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 169
Open Access[P244] Accuracy of ct numbers obtained by dira and monoenergetic plus algorithms in quantitative dual-energy computed tomography