Efficacy of a home blood pressure monitoring programme on therapeutic compliance in hypertension: the EAPACUM–HTA study
Authors:
- Emilio Márquez-ContrerasEMEmilio Márquez-Contreras
- Nieves Martell-ClarosNMNieves Martell-Claros
- Vicente Gil-GuillénVGVicente Gil-Guillén
- Mariano de la Figuera-Von WichmannMWMariano de la Figuera-Von Wichmann
- José Joaquín Casado-MartínezJCJosé Joaquín Casado-Martínez
- José Luis Martin-De PablosJPJosé Luis Martin-De Pablos
- Montse FiguerasMFMontse Figueras
- Jordi GaleraJGJordi Galera
- Alicia SerraASAlicia Serra
- 1 January 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 24 (1) , 169-175
Abstract
To evaluate the efficacy of a programme of home blood pressure measurement (HBPM) on therapeutic compliance in mild-to-moderate hypertension. A prospective controlled multicentre clinical trial. Forty primary care centres in Spain, with a duration of 6 months. A total of 250 patients with newly diagnosed or uncontrolled hypertension were included. The patients were randomly selected and distributed in two groups: (1) the control group (CG) who received standard health intervention; (2) the intervention group (IG): the patients in this group received an OMRON in their homes for a programme of HBPM. Four visits were scheduled, for the measurement of blood pressure (BP). They were provided with an electronic monitor for measuring compliance (monitoring events medication system; MEMS). Therapeutic compliance was defined as a drug consumption of 80–110%. A number of variables were calculated using the MEMS. The mean BP were calculated and the percentage of controlled patients. A total of 200 patients completed the study (100 in each group). Compliance was observed in 74 and 92%, respectively, in the CG and IG [95% confidence interval (CI) 63.9–84.1 and 86.7–97.3; P = 0.0001], the mean percentage compliances were 87.6 and 93.5% (95% CI 81.2–94 and 80.7–98.3; P = 0.0001), the percentages of correct days were 83.6 and 89.4%, the percentages of subjects who took the medication at the prescribed time were 79.89 and 88.06%, and the levels of therapeutic cover were 86.7 and 93.1%. The number needed to treat to avoid one case of non-compliance was 5.6 patients. The differences in the mean decreases in BP were significant for diastolic BP, with a greater decrease observed in the IG. An HBPM programme using electronic monitors is effective in improving compliance in arterial hypertension, measured using the MEMS.Keywords
This publication has 19 references indexed in Scilit:
- Facts and fiction of poor compliance as a cause of inadequate blood pressure controlJournal Of Hypertension, 2004
- What has been learned from electronic monitoring of compliance with antihypertensive medications?Journal Of Hypertension, 2004
- How Can We Improve Adherence to Blood Pressure–Lowering Medication in Ambulatory Care?Archives of internal medicine (1960), 2004
- Control de la presión arterial en la población hipertensa española atendida en atención primaria. Estudio PRESCAP 2002Medicina Clinica, 2004
- Helping Patients Follow Prescribed TreatmentJAMA, 2002
- Evolución de la hipertensión de bata blanca a hipertensión mantenida. Seguimiento durante un año mediante monitorización ambulatoria de la presión arterialMedicina Clinica, 2001
- How well is hypertension controlled in Europe?Journal Of Hypertension, 2000
- El cumplimiento terapéutico en la hipertensión arterial. Ensayo sobre la intervención durante 2 años mediante educación sanitariaAtencion Primaria, 2000
- Pharmacoeconomic Consequences of Variable Patient Compliance With Prescribed Drug RegimensPharmacoEconomics, 1999
- Effectiveness of Interventions to Improve Patient ComplianceMedical Care, 1998