Efficacy of a Novel Bipolar Radiofrequency Clamp: An Acute Porcine Model
Authors:
- Martha McGilvrayMMMartha McGilvray
- Ralph J. DamianoRDRalph J. Damiano
- 1 September 2022
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 17 (5) , 409-415
Abstract
Objective: Expert consensus guidelines recommend surgical ablation (SA) for patients with symptomatic atrial fibrillation (AF), but less than half of patients with AF undergoing cardiac procedures receive concomitant SA. Complete isolation of the left atrial posterior wall (LAPW) has been shown to be the most critical part of the Cox maze procedure. The purpose of this study was to investigate the performance of a novel radiofrequency (RF) bipolar device, EnCompass™ (AtriCure, Inc., Mason, OH, USA), designed to isolate the LAPW in a single application. Methods: Five adult pigs underwent SA in a beating heart model. After a single ablation, the heart was arrested, explanted, and stained with triphenyl-tetrazolium-chloride for histological assessment. Each lesion was sectioned, and the ablation depth, muscle, and fat thickness were determined. The lesion width, energy delivery, and ablation times were compared with those from a reference RF clamp (Synergy™, AtriCure). Results: Transmurality was documented in 100% of lesions (5 of 5) and cross sections (160 of 160). Electrical isolation was documented in every instance. There was no evidence of clot, charring, or pulmonary vein stenosis. Compared with the reference clamp, the lesions created by the EnCompass™ clamp were 1.5 times wider on average. The average energy delivered was 5 times higher over a duration that was 4.5 times longer due to the increased volume of tissue ablated. Conclusions: The EnCompass™ clamp reproducibly created transmural isolation of the LAPW with a single application. This may allow for simplification of the SA strategy and increased adoption of AF treatment during concomitant surgery.Keywords
Funding Information
- AtriCure
This publication has 38 references indexed in Scilit:
- Ablation Technology for the Surgical Treatment of Atrial FibrillationASAIO Journal, 2013
- Cox-Maze IV Results for Patients With Lone Atrial Fibrillation Versus Concomitant Mitral DiseaseThe Annals of Thoracic Surgery, 2012
- Performance of a Novel Dual-Electrode Bipolar Radiofrequency Ablation Device a Chronic Porcine StudyInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2011
- The Cox maze IV procedure: Predictors of late recurrenceThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Animal studies of epicardial atrial ablationHeart Rhythm, 2009
- Wide Variations in Energy Delivery Using an Impedance-Controlled Algorithm in Bipolar Radiofrequency Ablation: Evidence against Fixed Time AblationInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2007
- The effect of ablation technology on surgical outcomes after the Cox-maze procedure: A propensity analysisThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Secular Trends in Incidence of Atrial Fibrillation in Olmsted County, Minnesota, 1980 to 2000, and Implications on the Projections for Future PrevalenceCirculation, 2006
- Surgical treatment of atrial fibrillation; a systematic review☆European Journal of Cardio-Thoracic Surgery, 2005
- Successful Performance of Cox-Maze Procedure on Beating Heart Using Bipolar Radiofrequency Ablation: A Feasibility Study in AnimalsThe Annals of Thoracic Surgery, 2004