A Review of the Performance of Artifact Filtering Algorithms for Cardiopulmonary Resuscitation
Authors:
- Yushun GongYGYushun Gong
- Bihua ChenBCBihua Chen
- Yongqin LiYLYongqin Li
Open Access
- 1 January 2013
- journal article
- research article
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 4 (2) , 185-202
Abstract
Various filtering strategies have been adopted and investigated to suppress the cardiopulmonary resuscitation (CPR) artifact. In this article, two types of artifact removal methods are reviewed: one is the method that removes CPR artifact using only ECG signals, and the other is the method with additional reference signals, such as acceleration, compression depth and transthoracic impedance. After filtering, the signal‐to‐noise ratio is improved from 0 dB to greater than 2.8 dB, the sensitivity is increased to > 90% as recommended by the American Heart Association, whereas the specificity was far from the recommended 95%, which is considered to be the major drawback of the available artifact removal methods. The overall performance of the adaptive filtering methods with additional reference signal outperforms the methods using only ECG signals. Further research should focus on the refinement of artifact filtering methods and the improvement of shock advice algorithms with the presence of CPR.Keywords
Funding Information
- National Natural Science Foundation of China (NSFC31070884)
- National Natural Science Foundation of China (NSFC81271656)
- Foundation for the Author of National Excellent Doctoral Dissertation of the People's Republic of China (FANEDD 201060)
- Natural Science Foundation of Chongqing Municipality (CQCSTC2010BB5023)
This publication has 52 references indexed in Scilit:
- Perishock PauseCirculation, 2011
- Use of independent component analysis for reducing CPR artefacts in human emergency ECGsResuscitation, 2010
- Reduction of CPR artifacts in the ventricular fibrillation ECG by coherent line removalBioMedical Engineering OnLine, 2010
- Minimal interruption of cardiopulmonary resuscitation for a single shock as mandated by automated external defibrillations does not compromise outcomes in a porcine model of cardiac arrest and resuscitationCritical Care Medicine, 2008
- A unified framework for adaptive filter algorithms with variable step-sizeComputers and Electrical Engineering, 2008
- Interruptions of Chest Compressions During Emergency Medical Systems ResuscitationCirculation, 2005
- Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECGResuscitation, 2004
- Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithmIEEE Transactions on Biomedical Engineering, 2002
- Coherent line removal: Filtering out harmonically related line interference from experimental data, with application to gravitational wave detectorsPhysical Review D, 1998
- Predicting survival from out-of-hospital cardiac arrest: A graphic modelAnnals of Emergency Medicine, 1993