Yushun Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yushun Gong has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Pesenti
Department of Pathophysiology and Transplantation, Università di Milano, Milan, Italy
1 shared publication Bihua Chen
1 shared publication- Francesca Fumagalli
Department of Acute Brain and Cardiovascular Injury, Istituto di Ricerche Farmacologiche Mario Negri IRCCS , Via Mario Negri 2, 20156 Milano
1 shared publication - Giancarlo Cesana
University of Milano - Bicocca, Monza, Italy
1 shared publication - Giuseppe Ristagno
S.C. Ricerca Innovazione e Trasferimento Tecnologico, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
1 shared publication - Marcella Bozzola
Azienda Regionale Emergenza Urgenza (AREU), Via Alfredo Campanini, 6, 20124, Milan, Italy.
1 shared publication
Latest Publications
- Open Access
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 1-9
Combining multiple ECG features does not improve prediction of defibrillation outcome compared to single features in a large population of out-of-hospital cardiac arrests
Introduction: Quantitative electrocardiographic (ECG) waveform analysis provides a noninvasive reflection of the metabolic milieu of the myocardium during resuscitation and is a potentially useful tool to optimize the defibrillation strategy. However, whether combining multiple ECG features can improve the capability of defibrillation outcome prediction in comparison to single feature analysis is still uncertain. Methods: A total of 3828 defibrillations from 1617 patients who experienced out-of-hospital cardiac arrest were analyzed. A 2.048-s ECG trace prior to each defibrillation without chest compressions was used for the analysis. Sixteen predictive features were optimized through the training dataset that included 2447 shocks from 1050 patients. Logistic regression, neural network and support vector machine were used to combine multiple features for the prediction of defibrillation outcome. Performance between single and combined predictive features were compared by area under receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and prediction accuracy (PA) on a validation dataset that consisted of 1381 shocks from 567 patients. Results: Among the single features, mean slope (MS) outperformed other methods with an AUC of 0.876. Combination of complementary features using neural network resulted in the highest AUC of 0.874 among the multifeature-based methods. Compared to MS, no statistical difference was observed in AUC, sensitivity, specificity, PPV, NPV and PA when multiple features were considered. Conclusions: In this large dataset, the amplitude-related features achieved better defibrillation outcome prediction capability than other features. Combinations of multiple electrical features did not further improve prediction performance.
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 1-9
Open AccessCombining multiple ECG features does not improve prediction of defibrillation outcome compared to single features in a large population of out-of-hospital cardiac arrests
Introduction: Quantitative electrocardiographic (ECG) waveform analysis provides a noninvasive reflection of the metabolic milieu of the myocardium during resuscitation and is a potentially useful tool to optimize the defibrillation strategy. However, whether combining multiple ECG features can improve the capability of defibrillation outcome prediction in comparison to single feature analysis is still uncertain. Methods: A total of 3828 defibrillations from 1617 patients who experienced out-of-hospital cardiac arrest were analyzed. A 2.048-s ECG trace prior to each defibrillation without chest compressions was used for the analysis. Sixteen predictive features were optimized through the training dataset that included 2447 shocks from 1050 patients. Logistic regression, neural network and support vector machine were used to combine multiple features for the prediction of defibrillation outcome. Performance between single and combined predictive features were compared by area under receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and prediction accuracy (PA) on a validation dataset that consisted of 1381 shocks from 567 patients. Results: Among the single features, mean slope (MS) outperformed other methods with an AUC of 0.876. Combination of complementary features using neural network resulted in the highest AUC of 0.874 among the multifeature-based methods. Compared to MS, no statistical difference was observed in AUC, sensitivity, specificity, PPV, NPV and PA when multiple features were considered. Conclusions: In this large dataset, the amplitude-related features achieved better defibrillation outcome prediction capability than other features. Combinations of multiple electrical features did not further improve prediction performance.
- Open Access
- 1 January 2013
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 4 (2) , 185-202
A Review of the Performance of Artifact Filtering Algorithms for Cardiopulmonary Resuscitation
Various filtering strategies have been adopted and investigated to suppress the cardiopulmonary resuscitation (CPR) artifact. In this article, two types of artifact removal methods are reviewed: one is the method that removes CPR artifact using only ECG signals, and the other is the method with additional reference signals, such as acceleration, compression depth and transthoracic impedance. After filtering, the signal‐to‐noise ratio is improved from 0 dB to greater than 2.8 dB, the sensitivity is increased to > 90% as recommended by the American Heart Association, whereas the specificity was far from the recommended 95%, which is considered to be the major drawback of the available artifact removal methods. The overall performance of the adaptive filtering methods with additional reference signal outperforms the methods using only ECG signals. Further research should focus on the refinement of artifact filtering methods and the improvement of shock advice algorithms with the presence of CPR.
- 1 January 2013
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 4 (2) , 185-202
Open AccessA Review of the Performance of Artifact Filtering Algorithms for Cardiopulmonary Resuscitation
Various filtering strategies have been adopted and investigated to suppress the cardiopulmonary resuscitation (CPR) artifact. In this article, two types of artifact removal methods are reviewed: one is the method that removes CPR artifact using only ECG signals, and the other is the method with additional reference signals, such as acceleration, compression depth and transthoracic impedance. After filtering, the signal‐to‐noise ratio is improved from 0 dB to greater than 2.8 dB, the sensitivity is increased to > 90% as recommended by the American Heart Association, whereas the specificity was far from the recommended 95%, which is considered to be the major drawback of the available artifact removal methods. The overall performance of the adaptive filtering methods with additional reference signal outperforms the methods using only ECG signals. Further research should focus on the refinement of artifact filtering methods and the improvement of shock advice algorithms with the presence of CPR.