Stem subsidence in total hip arthroplasty: retrospective investigation of a short stem using a simple measurement approach
Open Access
- 16 December 2024
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Abstract
Background: Uncemented total hip arthroplasty (THA) is a successful treatment for advanced hip joint diseases. More recently, short stems became increasingly popular, but stem subsidence remains a concern. This study investigates early short stem subsidence in a large patient cohort using a simple measurement approach for everyday practice. Methods: This retrospective, single center, single implant design study included 1000 patients with primary THA. Subsidence was evaluated using standardized weight-bearing radiographs taken 3–5 days and 2–3 weeks postoperatively with full weight-bearing (FWB). A novel Subsidence Index (SID) was introduced to quantify stem subsidence in a simple and reproducible manner. The SID is calculated by averaging four distinct linear measurements between defined anatomical landmarks on the femur and the implant, captured on standard radiographs without additional software. Results: Out of all analyzed patients 6% (60/1000) had subsidence of more than 3 mm. The mean subsidence was 1.3 mm (range, 0 to 16.25 mm). There were 0.6% (6) who underwent stem revision for symptomatic subsidence. Men and obese patients had greater subsidence. However, patient age, BMI, stems without lateral bone contact and other demographic factors were not associated with subsidence. Conclusion: Early subsidence is relatively frequent with this uncemented short stem, however revisions are rare. Patients with risk factors should be counseled regarding FWB and radiographic controls should be performed. The SID provides an easy, non-invasive and inexpensive tool for early subsidence assessment; however, its simplicity limits its accuracy. Further research is needed in comparison to more elaborate methods.Keywords
Funding Information
- Universitätsklinikum Münster
This publication has 23 references indexed in Scilit:
- Femoral stem subsidence in cementless total hip arthroplasty: a retrospective single-centre studyInternational Orthopaedics, 2018
- Weighing in on Body Mass Index and Infection After Total Joint Arthroplasty: Is There Evidence for a Body Mass Index Threshold?Clinical Orthopaedics and Related Research, 2018
- Outcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCAArchives of orthopaedic and trauma surgery, 2017
- Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term StudyClinical Orthopaedics and Related Research, 2016
- Analysis of migration of the Nanos® short-stem hip implant within two years after surgeryInternational Orthopaedics, 2015
- Migration pattern of a femoral short-stem prosthesis: a 2-year EBRA-FCA-studyArchives of orthopaedic and trauma surgery, 2014
- Subsidence of a cementless femoral component influenced by body weight and body mass indexInternational Orthopaedics, 2011
- Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA studyInternational Orthopaedics, 2009
- Progressive subsidence of a tapered, proximally coated femoral stem in total hip arthroplastyInternational Orthopaedics, 2008
- The MIS anterolateral approach for THADer Orthopäde, 2006