Outcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCA
Open Access
- 2 February 2017
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (3) , 431-439
Abstract
Introduction The principle of implanting a calcar-guided short stem consists of an individual alignment alongside the medial calcar providing the ability of reconstructing varus and valgus anatomy in a great variety. However, still, there are broad concerns about the safety of extensive varus and valgus positioning in regard to stability, bony alterations, and periprosthetic fractures. Materials and methods 216 total hip arthroplasties using a calcar-guided short stem (optimys, Mathys Ltd.) in 162 patients were included. Depending on postoperative CCD angle, hips were divided into five groups (A–E). Varus- and valgus tilt and axial subsidence were assessed by “Einzel-Bild-Roentgen-Analyse”(EBRA-FCA, femoral component analysis) over a 2-year follow-up. The incidence of stress-shielding and cortical hypertrophy as well as clinical outcome [Harris Hip Score (HHS)] were reported. Results Postoperative CCD angles ranged from 117.9° to 145.6° and mean postoperative CCD angles in group A–E were 123.3°, 128.0°, 132.4°, 137.5°, and 142.5°, respectively. After 2 years, the mean varus/valgus tilt was −0.16°, 0.37°, 0.48°, 0.01°, and 0.86°, respectively (p = 0.502). Axial subsidence after 2 years was 1.20, 1.02, 1.44, 1.50, and 2.62 mm, respectively (p = 0.043). No periprosthetic fractures occurred and none of the stems had to be revised. Rates of stress-shielding and cortical hypertrophy as well as HHS showed no significant difference between the groups. Conclusions Valgus alignment results in increased subsidence but does not affect the clinical outcome. There is no difference in stress shielding and cortical hypertrophy between the groups. The authors recommend long term monitoring of valgus aligned stems.Keywords
This publication has 29 references indexed in Scilit:
- Radiostereometric analysis of early implant migration – a valuable tool to ensure proper introduction of new implantsActa Orthopaedica, 2012
- Primary stability and strain distribution of cementless hip stems as a function of implant designClinical Biomechanics, 2012
- The Nanos Short Stem in Total Hip Arthroplasty: A Mid Term Follow-UpHIP International, 2011
- Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry studyInternational Orthopaedics, 2011
- Excessive distal migration of fiber-mesh coated femoral stemsActa Orthopaedica, 2011
- Postoperative Veränderungen von Offset, CCD-Winkel und Beinlänge nach Implantation einer metadiaphysär fixierten Kurzschaftprothese – eine radiologische UntersuchungZeitschrift für Orthopädie und Unfallchirurgie, 2011
- Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stemsThe Journal of Bone and Joint Surgery. British volume, 2001
- The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCAThe Journal of Bone and Joint Surgery. British volume, 1999
- Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1999
- Distal cortical hypertrophy following total hip arthroplastyThe Journal of Arthroplasty, 1988