The role of implants and implant prostheses on the accuracy and artifacts of cone-beam computed tomography: an in-vitro study
Authors:
Open Access
- 6 January 2024
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Abstract
To assess the accuracy of CBCT in implant-supported prostheses and to evaluate metal artifacts with and without implants or implant prostheses. Accuracy and artifacts were assessed in the dried mandible at three points on the buccal and lingual cortical plates on the mandible's body near the crest and the base. On the buccal cortical plate, these points were labelled as A, B and C near the crest and D, E and F near the base of the body of the mandible. Similarly, points a to f were marked on the lingual cortical plate corresponding to points A to F. The study had two control groups, C0 for physical linear measurement (PLM) and C1 for radiographic linear measurement (RLM) and artifact assessment. There were seven test groups, TG 1 to 7, progressing from a single implant to implant full-arch prosthesis. For accuracy assessment, PLM was compared to RLM. CBCT artifacts were investigated in images integrated at 0.25 mm, 10 mm, and 20 mm at regions of interest on concentric circles at different intersecting angles by comparing grayscale values at C1 and TG1 to 7. The data were collected and statistically analyzed. A significant difference was observed between C0 and C1, and RLM in test groups at the superior axial plane. Similarly, PLM and test RLM in the sagittal plane at A-B, B-C, and D-E were statistically significant. A significant difference between PLM and RLM was also observed in the vertical plane at A-D, B-E, and C-F. Quantification of CBCT artifacts in the presence of implants or prostheses revealed that full-arch prostheses had the highest mean grayscale value, whereas single implants with a prosthesis had the lowest. The mean grayscale change was greatest around the implant and implant prosthesis. The mean grayscale value was maximum at 20 mm voxel integration scales (VIS) and lowest at 0.25 mm. CBCT is a clinically reliable device. Metal in implants or implant-supported prostheses prevents true assessment of the peri-implant area; therefore, lower VIS is suggested in the presence of implants or implant prostheses.Keywords
This publication has 32 references indexed in Scilit:
- In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomographyClinical Oral Implants Research, 2012
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- Cone-beam CT in the assessment of mandibular invasion by oral squamous cell carcinoma: results of the preliminary studyInternational Journal of Oral and Maxillofacial Surgery, 2010
- Reproducibility of 3 Different Tracing Methods Based on Cone Beam Computed Tomography in Determining the Anatomical Position of the Mandibular CanalJournal of Oral and Maxillofacial Surgery, 2010
- On cone‐beam computed tomography artifacts induced by titanium implantsClinical Oral Implants Research, 2009
- Conebeam CT of the Head and Neck, Part 1: Physical PrinciplesAmerican Journal of Neuroradiology, 2009
- Comparison of Different Methods of Assessing Alveolar Ridge Dimensions Prior to Dental Implant PlacementJournal of Periodontology, 2008
- Beam hardening artefacts occur in dental implant scans with the NewTom®cone beam CT but not with the dental 4-row multidetector CTDentomaxillofacial Radiology, 2007
- The Use of Cone Beam Computed Tomography as an Aid in Evaluating and Treatment Planning for Mandibular CancerJournal of Oral and Maxillofacial Surgery, 2007
- Metal streak artifacts in X-ray computed tomography: a simulation studyIEEE Transactions on Nuclear Science, 1999