Jyoti Paliwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jyoti Paliwal has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Vineet Sharma
Department of Prosthodontics, RUHS. College of Dental Sciences, Jaipur, India
6 shared publications- Kamal K. Meena
Prosthodontics, Rajasthan University of Health Sciences (RUHS) College of Dental Sciences, Jaipur, IND
4 shared publications - Ashish Dadarwal
Prosthodontics, Rajasthan University of Health Sciences (RUHS) College of Dental Sciences, Jaipur, IND
3 shared publications Kamal Kumar Meena
Department of Prosthodontics, RUHS. College of Dental Sciences, Jaipur, India
3 shared publications- Balwant Gurjar
Prosthodontics, Rajasthan University of Health Sciences (RUHS) College of Dental Sciences, Jaipur, IND
2 shared publications Neha Gupta
Department of Prosthodontics, RUHS. College of Dental Sciences, Jaipur, India
2 shared publications
Latest Publications
- Open Access
- 5 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Influence of PEEK surface modification with titanium for improving osseointegration: an in vitro study
This study aimed to examine the impact of PEEK surface modification with titanium to enhance osseointegration. The assessment included the bond strength of the TiO2 surface coating, as well as an analysis of the hydrophilicity and cell adhesion properties of TiO2-coated PEEK. The study also explored whether aging affected TiO2-coated PEEK. The study used 51 disk specimens of ceramic-reinforced PEEK, prepared by wet milling. The disk surfaces were polished and divided into three groups based on surface modification or treatment. The control group (CG) included seven specimens without TiO2 coating. The nascent group included 22 TiO2-surface-coated specimens, subdivided equally into the untreated nascent group (NG) and the photo-functionalized, UV-treated nascent group (NGP). The remaining specimens were aged for four weeks and similarly divided into the untreated aged group (AG) and the photo-functionalized, UV-treated aged group (AGP). In the CG, three specimens were evaluated for hydrophilicity, and the remaining four for stem cell culture. For the NG, NGP, AG, and AGP groups, three specimens were evaluated for hydrophilicity, while four specimens were assessed for cell growth and TiO2 coating bond strength. Bond strength was evaluated using a scratch test, showing an average strength of 24.56 ± 2.28 MPa, with no significant difference between groups. Hydrophilicity was measured via contact angle, revealing that untreated ceramic-reinforced PEEK exhibited hydrophobic properties (99.11 ± 1.07 degrees). The NGP group had the lowest contact angle, indicating the highest wettability. The cell adhesion test showed that NGP had the highest number of adhered cells, followed by NG, AGP, AG, and CG. The study suggests that TiO2-coated PEEK can serve as a biocompatible, hydrophilic material with improved wettability and osteoblastic cell adhesion.
- 5 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessInfluence of PEEK surface modification with titanium for improving osseointegration: an in vitro study
This study aimed to examine the impact of PEEK surface modification with titanium to enhance osseointegration. The assessment included the bond strength of the TiO2 surface coating, as well as an analysis of the hydrophilicity and cell adhesion properties of TiO2-coated PEEK. The study also explored whether aging affected TiO2-coated PEEK. The study used 51 disk specimens of ceramic-reinforced PEEK, prepared by wet milling. The disk surfaces were polished and divided into three groups based on surface modification or treatment. The control group (CG) included seven specimens without TiO2 coating. The nascent group included 22 TiO2-surface-coated specimens, subdivided equally into the untreated nascent group (NG) and the photo-functionalized, UV-treated nascent group (NGP). The remaining specimens were aged for four weeks and similarly divided into the untreated aged group (AG) and the photo-functionalized, UV-treated aged group (AGP). In the CG, three specimens were evaluated for hydrophilicity, and the remaining four for stem cell culture. For the NG, NGP, AG, and AGP groups, three specimens were evaluated for hydrophilicity, while four specimens were assessed for cell growth and TiO2 coating bond strength. Bond strength was evaluated using a scratch test, showing an average strength of 24.56 ± 2.28 MPa, with no significant difference between groups. Hydrophilicity was measured via contact angle, revealing that untreated ceramic-reinforced PEEK exhibited hydrophobic properties (99.11 ± 1.07 degrees). The NGP group had the lowest contact angle, indicating the highest wettability. The cell adhesion test showed that NGP had the highest number of adhered cells, followed by NG, AGP, AG, and CG. The study suggests that TiO2-coated PEEK can serve as a biocompatible, hydrophilic material with improved wettability and osteoblastic cell adhesion.
- Open Access
- 6 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
The role of implants and implant prostheses on the accuracy and artifacts of cone-beam computed tomography: an in-vitro study
To assess the accuracy of CBCT in implant-supported prostheses and to evaluate metal artifacts with and without implants or implant prostheses. Accuracy and artifacts were assessed in the dried mandible at three points on the buccal and lingual cortical plates on the mandible's body near the crest and the base. On the buccal cortical plate, these points were labelled as A, B and C near the crest and D, E and F near the base of the body of the mandible. Similarly, points a to f were marked on the lingual cortical plate corresponding to points A to F. The study had two control groups, C0 for physical linear measurement (PLM) and C1 for radiographic linear measurement (RLM) and artifact assessment. There were seven test groups, TG 1 to 7, progressing from a single implant to implant full-arch prosthesis. For accuracy assessment, PLM was compared to RLM. CBCT artifacts were investigated in images integrated at 0.25 mm, 10 mm, and 20 mm at regions of interest on concentric circles at different intersecting angles by comparing grayscale values at C1 and TG1 to 7. The data were collected and statistically analyzed. A significant difference was observed between C0 and C1, and RLM in test groups at the superior axial plane. Similarly, PLM and test RLM in the sagittal plane at A-B, B-C, and D-E were statistically significant. A significant difference between PLM and RLM was also observed in the vertical plane at A-D, B-E, and C-F. Quantification of CBCT artifacts in the presence of implants or prostheses revealed that full-arch prostheses had the highest mean grayscale value, whereas single implants with a prosthesis had the lowest. The mean grayscale change was greatest around the implant and implant prosthesis. The mean grayscale value was maximum at 20 mm voxel integration scales (VIS) and lowest at 0.25 mm. CBCT is a clinically reliable device. Metal in implants or implant-supported prostheses prevents true assessment of the peri-implant area; therefore, lower VIS is suggested in the presence of implants or implant prostheses.
- 6 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessThe role of implants and implant prostheses on the accuracy and artifacts of cone-beam computed tomography: an in-vitro study
To assess the accuracy of CBCT in implant-supported prostheses and to evaluate metal artifacts with and without implants or implant prostheses. Accuracy and artifacts were assessed in the dried mandible at three points on the buccal and lingual cortical plates on the mandible's body near the crest and the base. On the buccal cortical plate, these points were labelled as A, B and C near the crest and D, E and F near the base of the body of the mandible. Similarly, points a to f were marked on the lingual cortical plate corresponding to points A to F. The study had two control groups, C0 for physical linear measurement (PLM) and C1 for radiographic linear measurement (RLM) and artifact assessment. There were seven test groups, TG 1 to 7, progressing from a single implant to implant full-arch prosthesis. For accuracy assessment, PLM was compared to RLM. CBCT artifacts were investigated in images integrated at 0.25 mm, 10 mm, and 20 mm at regions of interest on concentric circles at different intersecting angles by comparing grayscale values at C1 and TG1 to 7. The data were collected and statistically analyzed. A significant difference was observed between C0 and C1, and RLM in test groups at the superior axial plane. Similarly, PLM and test RLM in the sagittal plane at A-B, B-C, and D-E were statistically significant. A significant difference between PLM and RLM was also observed in the vertical plane at A-D, B-E, and C-F. Quantification of CBCT artifacts in the presence of implants or prostheses revealed that full-arch prostheses had the highest mean grayscale value, whereas single implants with a prosthesis had the lowest. The mean grayscale change was greatest around the implant and implant prosthesis. The mean grayscale value was maximum at 20 mm voxel integration scales (VIS) and lowest at 0.25 mm. CBCT is a clinically reliable device. Metal in implants or implant-supported prostheses prevents true assessment of the peri-implant area; therefore, lower VIS is suggested in the presence of implants or implant prostheses.
- Open Access
- 18 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33940
An In Vitro Comparison of Zirconia and Hybrid Ceramic Crowns With Heavy Chamfer and Shoulder Finish Lines
This in vitro study aimed to compare the marginal fit and internal adaptation of computer-aided designed and computer-aided manufactured (CAD-CAM) zirconia and hybrid ceramic crowns on heavy chamfer and shoulder finish line designs using silicon replica method. Forty die samples were divided into four groups of 10 dies each. Out of 40 diecasts scanned, zirconia crowns were milled on 20 casts (10 prepared with shoulder and 10 prepared with heavy chamfer finish line design), while hybrid ceramic crowns were milled on the rest of the 20 casts. After milling crowns, the silicone replica technique measured the marginal fit and internal adaptation. The heavy chamfer finish line design provided a better marginal fit than the shoulder finish line design for zirconia and hybrid ceramic crowns. Hybrid ceramic crowns had a better marginal fit and internal adaptation than zirconia crowns, both at heavy chamfer and shoulder finish line design. The gap at the margin was less than the axial and occlusal walls, and the maximum gap was observed in the occlusal area. In addition, the marginal gap was less than the internal gap, which showed a positive correlation with each other. The study concluded that the difference in CAD-CAM materials and finish line designs influences marginal fit and crown restoration's internal adaptation. A heavy chamfer finish line design provides a better marginal fit for zirconia and hybrid ceramic crowns than a shoulder finish line design. Hybrid ceramic crowns have a better marginal fit and internal adaptation than zirconia crowns in heavy chamfer and shoulder finish lines.
- 18 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33940
Open AccessAn In Vitro Comparison of Zirconia and Hybrid Ceramic Crowns With Heavy Chamfer and Shoulder Finish Lines
This in vitro study aimed to compare the marginal fit and internal adaptation of computer-aided designed and computer-aided manufactured (CAD-CAM) zirconia and hybrid ceramic crowns on heavy chamfer and shoulder finish line designs using silicon replica method. Forty die samples were divided into four groups of 10 dies each. Out of 40 diecasts scanned, zirconia crowns were milled on 20 casts (10 prepared with shoulder and 10 prepared with heavy chamfer finish line design), while hybrid ceramic crowns were milled on the rest of the 20 casts. After milling crowns, the silicone replica technique measured the marginal fit and internal adaptation. The heavy chamfer finish line design provided a better marginal fit than the shoulder finish line design for zirconia and hybrid ceramic crowns. Hybrid ceramic crowns had a better marginal fit and internal adaptation than zirconia crowns, both at heavy chamfer and shoulder finish line design. The gap at the margin was less than the axial and occlusal walls, and the maximum gap was observed in the occlusal area. In addition, the marginal gap was less than the internal gap, which showed a positive correlation with each other. The study concluded that the difference in CAD-CAM materials and finish line designs influences marginal fit and crown restoration's internal adaptation. A heavy chamfer finish line design provides a better marginal fit for zirconia and hybrid ceramic crowns than a shoulder finish line design. Hybrid ceramic crowns have a better marginal fit and internal adaptation than zirconia crowns in heavy chamfer and shoulder finish lines.
- Open Access
- 9 October 2022
- Published by Springer Nature in Cureus
- Vol. 14 (10) , e30132
Guidance Prostheses for Partial Mandibulectomy Patients: A Case Series
This case series discusses the fabrication of guidance prostheses (GPs) for patients who presented to the Department of Prosthodontics with marked mandibular deviation, resulting in facial disfigurement and deranged occlusion. These GPs guide the mandible to the unresected side to achieve stable occlusion. This case series included three approaches to reducing mandibular deviation: a maxillary guidance ramp, a mandibular guidance prosthesis, and a twin occlusal appliance. These approaches were used in conjunction with a well-planned mandibular exercise regimen. The earlier mandibular guidance therapy is started, the better the outcome. GPs are used until good occlusal relationships and proprioception are restored. These GPs can be discarded or used occasionally once a good occlusal relationship has been achieved.
- 9 October 2022
- Published by Springer Nature in Cureus
- Vol. 14 (10) , e30132
Open AccessGuidance Prostheses for Partial Mandibulectomy Patients: A Case Series
This case series discusses the fabrication of guidance prostheses (GPs) for patients who presented to the Department of Prosthodontics with marked mandibular deviation, resulting in facial disfigurement and deranged occlusion. These GPs guide the mandible to the unresected side to achieve stable occlusion. This case series included three approaches to reducing mandibular deviation: a maxillary guidance ramp, a mandibular guidance prosthesis, and a twin occlusal appliance. These approaches were used in conjunction with a well-planned mandibular exercise regimen. The earlier mandibular guidance therapy is started, the better the outcome. GPs are used until good occlusal relationships and proprioception are restored. These GPs can be discarded or used occasionally once a good occlusal relationship has been achieved.
- Open Access
- 3 May 2022
- Published by Springer Nature in Cureus
- Vol. 14 (5) , e24687
A Novel Technique for Retention of the Immediate Obturator Following Maxillectomy in Mucormycosis: A Case Report
Mucormycosis is an aggressive opportunistic fungal infection that affects blood supply-rich areas such as the maxilla. Because of the compromised immune system caused by coronavirus disease 2019 (COVID-19) infection and diabetes, this infection has spread at a rapid rate. Early detection and treatment can reduce disease mortality and morbidity. However, the difficulties of prosthetic rehabilitation and the lack of multidisciplinary planning negatively influence the quality of life (QOL). This case report uses the novel concept of magnet-retained immediate prosthetic rehabilitation in such a case.
- 3 May 2022
- Published by Springer Nature in Cureus
- Vol. 14 (5) , e24687
Open AccessA Novel Technique for Retention of the Immediate Obturator Following Maxillectomy in Mucormycosis: A Case Report
Mucormycosis is an aggressive opportunistic fungal infection that affects blood supply-rich areas such as the maxilla. Because of the compromised immune system caused by coronavirus disease 2019 (COVID-19) infection and diabetes, this infection has spread at a rapid rate. Early detection and treatment can reduce disease mortality and morbidity. However, the difficulties of prosthetic rehabilitation and the lack of multidisciplinary planning negatively influence the quality of life (QOL). This case report uses the novel concept of magnet-retained immediate prosthetic rehabilitation in such a case.
- Open Access
- 7 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e23923
Comparative Evaluation of the Clinical Efficacy of Four Different Gingival Retraction Systems: An In Vivo Study
Introduction: There are numerous gingival retraction systems available on the market. This study aimed to evaluate the clinical efficacy of four gingival retraction systems, namely, impregnated retraction cord, gingival retraction capsule, retraction paste, and polyvinyl acetate strips. Methods: A total of 20 people were chosen for the study, and 100 specimens were collected. The specimens were classified into five groups based on the materials used for gingival displacement. On the first day, a baseline impression without gingival displacement was made. Afterward, impressions were made with any of the following four gingival retraction systems: impregnated retraction cord (SURE-Cord® Plus; Sure Dent Corporation, Jungwon-gu, South Korea), retraction capsule (3M ESPE astringent retraction paste capsule; 3M Corporation, St. Paul, MN), retraction paste (Traxodent® Hemodent® Paste Retraction System; Premier Dental Co., Plymouth Meeting, PA) and polyvinylacetate strips (Merocel; Merocel Co., Mystic, CT), with a 14-day interval between each system. The amount of gingival displacement was measured using an optical microscope as the distance from the tooth to the gingiva crest in a horizontal plane. Results: All experimental groups had higher gingival displacement than the control group (P < 0.01). Among the experimental groups, polyvinyl acetate strips had the highest gingival displacement value (541.65 μm), followed by impregnated retraction cord (505.37 μm), retraction capsule (333.57 μm), and retraction paste (230.63 μm). Conclusion: Within the limits of this in vivo study, significant differences in horizontal gingival displacement were discovered among the four evaluated systems. The horizontal displacement requirements of 200 μm were exceeded by all four systems. The maximum value for gingival displacement was found in polyvinyl acetate strips (Merocel), followed by impregnated retraction cord (SURE-Cord), and retraction capsule (3M ESPE), and the lowest value was found in retraction paste (Traxodent).
- 7 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e23923
Open AccessComparative Evaluation of the Clinical Efficacy of Four Different Gingival Retraction Systems: An In Vivo Study
Introduction: There are numerous gingival retraction systems available on the market. This study aimed to evaluate the clinical efficacy of four gingival retraction systems, namely, impregnated retraction cord, gingival retraction capsule, retraction paste, and polyvinyl acetate strips. Methods: A total of 20 people were chosen for the study, and 100 specimens were collected. The specimens were classified into five groups based on the materials used for gingival displacement. On the first day, a baseline impression without gingival displacement was made. Afterward, impressions were made with any of the following four gingival retraction systems: impregnated retraction cord (SURE-Cord® Plus; Sure Dent Corporation, Jungwon-gu, South Korea), retraction capsule (3M ESPE astringent retraction paste capsule; 3M Corporation, St. Paul, MN), retraction paste (Traxodent® Hemodent® Paste Retraction System; Premier Dental Co., Plymouth Meeting, PA) and polyvinylacetate strips (Merocel; Merocel Co., Mystic, CT), with a 14-day interval between each system. The amount of gingival displacement was measured using an optical microscope as the distance from the tooth to the gingiva crest in a horizontal plane. Results: All experimental groups had higher gingival displacement than the control group (P < 0.01). Among the experimental groups, polyvinyl acetate strips had the highest gingival displacement value (541.65 μm), followed by impregnated retraction cord (505.37 μm), retraction capsule (333.57 μm), and retraction paste (230.63 μm). Conclusion: Within the limits of this in vivo study, significant differences in horizontal gingival displacement were discovered among the four evaluated systems. The horizontal displacement requirements of 200 μm were exceeded by all four systems. The maximum value for gingival displacement was found in polyvinyl acetate strips (Merocel), followed by impregnated retraction cord (SURE-Cord), and retraction capsule (3M ESPE), and the lowest value was found in retraction paste (Traxodent).
- Open Access
- 31 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23673
Microstrain Analysis of Selective Pressure Techniques for Mandibular Complete Denture Impression: An In Vivo Study
The present in vivo study was undertaken for microstrain analysis of the selective pressure impression technique using strain gauges in mandibular complete denture impression. Ten completely edentulous patients undergoing complete denture treatment were selected for the study. For each patient, mandibular casts were made, and two custom trays were fabricated on the mandibular cast. These mandibular trays were divided into two groups: those with mandibular impressions made in the custom tray with the use of a spacer (MST) and those without a spacer (MWS). For each patient, a primary impression was made by using an impression compound. After that, the primary cast was obtained, and the custom tray was fabricated by using auto polymerizing resin. Then strain gauges were attached to the particular areas of the tray. The customized tray with zinc oxide eugenol impression material was seated in the patient's mouth for the final impression. The strain produced during impression making at different areas was recorded by a multi-channel (six) strain amplifier and data logger (8-channel digital strain indicator NIC, Jaipur, India). The data obtained were subjected to statistical analysis using an independent t-test (for quantitative data within two groups). The level of significance was set at p=0.05 (p<0.05-significant, p<0.01-highly significant, p<0.0001-very highly significant). The comparison of the percentage of microstrain produced at the relief area with and without spacer tray design showed a statistically significant (p=0.001) result with a greater number of percentages of microstrain among those without spacers (94.19) than with spacer (72.09) tray design. The use of a tray with relief for selective pressure impression of an edentulous mandible resulted in a desirable pressure distribution at the alveolar crests and buccal shelves.
- 31 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23673
Open AccessMicrostrain Analysis of Selective Pressure Techniques for Mandibular Complete Denture Impression: An In Vivo Study
The present in vivo study was undertaken for microstrain analysis of the selective pressure impression technique using strain gauges in mandibular complete denture impression. Ten completely edentulous patients undergoing complete denture treatment were selected for the study. For each patient, mandibular casts were made, and two custom trays were fabricated on the mandibular cast. These mandibular trays were divided into two groups: those with mandibular impressions made in the custom tray with the use of a spacer (MST) and those without a spacer (MWS). For each patient, a primary impression was made by using an impression compound. After that, the primary cast was obtained, and the custom tray was fabricated by using auto polymerizing resin. Then strain gauges were attached to the particular areas of the tray. The customized tray with zinc oxide eugenol impression material was seated in the patient's mouth for the final impression. The strain produced during impression making at different areas was recorded by a multi-channel (six) strain amplifier and data logger (8-channel digital strain indicator NIC, Jaipur, India). The data obtained were subjected to statistical analysis using an independent t-test (for quantitative data within two groups). The level of significance was set at p=0.05 (p<0.05-significant, p<0.01-highly significant, p<0.0001-very highly significant). The comparison of the percentage of microstrain produced at the relief area with and without spacer tray design showed a statistically significant (p=0.001) result with a greater number of percentages of microstrain among those without spacers (94.19) than with spacer (72.09) tray design. The use of a tray with relief for selective pressure impression of an edentulous mandible resulted in a desirable pressure distribution at the alveolar crests and buccal shelves.
- Open Access
- 1 January 2022
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 22 (1) , 29-37
Evaluation of clinical and radiographic outcome of friction fit conical abutment system in implant-supported dental prostheses: An in vivo study
Aim: The purpose of this clinical study was to analyze the clinical feasibility of friction fit conical abutment system in implant-supported fixed dental prostheses as an alternative to cement and screw retention. Settings and Design: This was an in vivo longitudinal study. Materials and Methods: A total of 10 prostheses were designed as 3- or 4-unit fixed dental prostheses supported by two implants. All the subjects selected were evaluated for pocket probing depth (PPD) and marginal bone loss at the time of implant placement (T1), at the time of placement of friction fit prostheses (T2), and 12 months after placement of friction fit prostheses (T3). Marginal bone loss at T2 and T3 was measured with respect to bone levels at T1 and T2, respectively. The patient satisfaction was assessed at T2 and T3 using FDI clinical criteria and scoring system (modified by Monaco et al.). Statistical Analysis Used: Shapiro–Wilk test was employed to test the normality of data. Paired sample t-test was performed for quantitative variables. Results: A total of twenty implants were inserted in ten partially edentulous spaces; the average patient age was 50.2 years. No significant difference was seen between T2 and T3 for PPD. Comparison of marginal bone loss using paired t-test showed a statistically highly significant difference at T2 and T3 with higher value at T2. No prostheses were dislodged during postprosthetic follow-up. The survival rate was 100% for both the abutments and implants. No change in surface luster was observed 12 months following prosthetic rehabilitation in any case. No prostheses or framework fracture was reported and all patients were satisfied with the prosthesis received. Conclusions: Friction fit conical abutment system can act as a novel approach for the retention of implant-supported fixed dental prostheses.
- 1 January 2022
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 22 (1) , 29-37
Open AccessEvaluation of clinical and radiographic outcome of friction fit conical abutment system in implant-supported dental prostheses: An in vivo study
Aim: The purpose of this clinical study was to analyze the clinical feasibility of friction fit conical abutment system in implant-supported fixed dental prostheses as an alternative to cement and screw retention. Settings and Design: This was an in vivo longitudinal study. Materials and Methods: A total of 10 prostheses were designed as 3- or 4-unit fixed dental prostheses supported by two implants. All the subjects selected were evaluated for pocket probing depth (PPD) and marginal bone loss at the time of implant placement (T1), at the time of placement of friction fit prostheses (T2), and 12 months after placement of friction fit prostheses (T3). Marginal bone loss at T2 and T3 was measured with respect to bone levels at T1 and T2, respectively. The patient satisfaction was assessed at T2 and T3 using FDI clinical criteria and scoring system (modified by Monaco et al.). Statistical Analysis Used: Shapiro–Wilk test was employed to test the normality of data. Paired sample t-test was performed for quantitative variables. Results: A total of twenty implants were inserted in ten partially edentulous spaces; the average patient age was 50.2 years. No significant difference was seen between T2 and T3 for PPD. Comparison of marginal bone loss using paired t-test showed a statistically highly significant difference at T2 and T3 with higher value at T2. No prostheses were dislodged during postprosthetic follow-up. The survival rate was 100% for both the abutments and implants. No change in surface luster was observed 12 months following prosthetic rehabilitation in any case. No prostheses or framework fracture was reported and all patients were satisfied with the prosthesis received. Conclusions: Friction fit conical abutment system can act as a novel approach for the retention of implant-supported fixed dental prostheses.
- 1 September 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 126 (3) , 405.e1-405.e7
Influence of surface modification of titanium implants on improving osseointegration: An in vitro study
- 1 September 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 126 (3) , 405.e1-405.e7
Influence of surface modification of titanium implants on improving osseointegration: An in vitro study