Effects of syringe type and storage conditions on results of equine blood gas and acid-base analysis
Authors:
- Peter D. ConstablePCPeter D. Constable
- Ismail SenISIsmail Sen
- Laurent CouëtilLCLaurent Couëtil
- 1 July 2012
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 73 (7) , 979-987
Abstract
Objective—To determine effects of syringe type and storage conditions on blood gas and acid-base values for equine blood samples. Sample—Blood samples obtained from 8 healthy horses. Procedures—Heparinized jugular venous blood was equilibrated via a tonometer at 37°C with 12% O2 and 5% CO2. Aliquots (3 mL) of tonometer-equilibrated blood were collected in random order by use of a glass syringe (GS), general-purpose polypropylene syringe (GPPS), or polypropylene syringe designed for blood gas analysis (PSBGA) and stored in ice water (0°C) or at room temperature (22°C) for 0, 5, 15, 30, 60, or 120 minutes. Blood pH was measured, and blood gas analysis was performed; data were analyzed by use of multivariable regression analysis. Results—Blood Po2 remained constant for the reference method (GS stored at 0°C) but decreased linearly at a rate of 7.3 mm Hg/h when stored in a GS at 22°C. In contrast, Po2 increased when blood was stored at 0°C in a GPPS and PSBGA or at 22°C in a GPPS; however, Po2 did not change when blood was stored at 22°C in a PSBGA. Calculated values for plasma concentration of HCO3 and total CO2 concentration remained constant in the 3 syringe types when blood was stored at 22°C for 2 hours but increased when blood was stored in a GS or GPPS at 0°C. Conclusions and Clinical Relevance—Blood samples for blood gas and acid-base analysis should be collected into a GS and stored at 0°C or collected into a PSBGA and stored at room temperature.Keywords
This publication has 40 references indexed in Scilit:
- Effects of collecting blood into plastic heparinised Vacutainer®tubes and storage conditions on blood gas analysis values in horsesEquine Veterinary Journal, 2010
- Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheepAmerican Journal of Veterinary Research, 2010
- Potential preanalytical errors in whole-blood analysis: Effect of syringe sample volume on blood gas, electrolyte and lactate valuesScandinavian Journal of Clinical and Laboratory Investigation, 2009
- Changes in gas composition and acid‐base values of venous blood samples stored under different conditions in 4 domestic speciesVeterinary Clinical Pathology, 2007
- Effects of Syringe Type and Storage Temperature on Results of Blood Gas Analysis in Arterial Blood of HorsesJournal of Veterinary Internal Medicine, 2007
- The effects of ice‐water storage on blood gas and acid–base measurementsJournal of Veterinary Emergency and Critical Care, 2007
- Effects of syringe material and temperature and duration of storage on the stability of equine arterial blood gas variablesVeterinary Anaesthesia and Analgesia, 2004
- Effects of sample storage time, temperature and syringe type on blood gas tensions in samples with high oxygen partial pressures.Thorax, 1994
- Leakage of Oxygen from Blood and Water Samples Stored in Plastic and Glass SyringesBMJ, 1971
- Sampling and Storing of Blood for Determination of Acid-Rase StatusScandinavian Journal of Clinical and Laboratory Investigation, 1961