Real-world assessment of multipolar and point-by-point mapping for premature ventricular contraction ablation
Authors:
- Pedro A SousaPSPedro A Sousa
- Johanna TonkoJTJohanna Tonko
- Dagmara Dilling-BoerDDDagmara Dilling-Boer
- Sérgio BarraSBSérgio Barra
- Anna-Sophie EberlAEAnna-Sophie Eberl
- Borka PezoBPBorka Pezo
- Nuno Cortez-DiasNCNuno Cortez-Dias
- Paulo MedeirosPMPaulo Medeiros
- Moisés Rodríguez-MañeroMRMoisés Rodríguez-Mañero
- Ana LebreiroALAna Lebreiro
- Mariana PereiraMPMariana Pereira
Open Access
- 31 May 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (6)
Abstract
Aims: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. Methods and results: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the ‘Multipolar group’, where a dedicated high-density mapping catheter was employed, and the ‘PbP group’, where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41–65) years]—248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217–843) vs. 95 (42–185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476–5.108), P = 0.02]. Conclusion: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.Keywords
This publication has 20 references indexed in Scilit:
- Multielectrode Mapping and Pattern Matching Recognition for Left Premature Ventricular Contraction AblationJACC: Clinical Electrophysiology, 2019
- Safety and efficacy in ablation of premature ventricular contraction: data from the German ablation registryClinical Research in Cardiology, 2016
- Safety and Clinical Outcome of Catheter Ablation of Ventricular Arrhythmias Using Contact Force Sensing: Consecutive Case SeriesJournal of Cardiovascular Electrophysiology, 2015
- Ventricular Ectopy as a Predictor of Heart Failure and DeathJACC, 2015
- Multicenter Outcomes for Catheter Ablation of Idiopathic Premature Ventricular ComplexesJACC: Clinical Electrophysiology, 2015
- High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode SpacingCirculation: Arrhythmia and Electrophysiology, 2015
- EHRA/HRS/APHRS Expert Consensus on Ventricular ArrhythmiasHeart Rhythm, 2014
- Novel Algorithmic Methods in Mapping of Atrial and Ventricular TachycardiaCirculation: Arrhythmia and Electrophysiology, 2014
- Beneficial effects of catheter ablation of frequent premature ventricular complexes on left ventricular functionHeart, 2014
- Neurohormonal, Structural, and Functional Recovery Pattern After Premature Ventricular Complex Ablation Is Independent of Structural Heart Disease Status in Patients With Depressed Left Ventricular Ejection FractionJACC, 2013