Abstract
We present in this work alternative analytic formulations for the fan-beam tomographic backprojection operation and its associated adjoint transform in standard (equiangular) and linear (equidistant) detector geometries. The proposed formulations are obtained from a recent backprojection theorem in parallel tomography. Such formulations are written as a Bessel–Neumann series in the frequency domain that can be implemented as an O ⁢ ( N 2.3729 ) matrix multiplication. Proofs are provided together with numerical simulations compared with conventional fan-beam O ⁢ ( N 3 ) backprojection representations showing more robustness when dealing with highly noisy data.
Funding Information
  • Fonds Wetenschappelijk Onderzoek (S004217N)

This publication has 23 references indexed in Scilit: