A transient reactive current compensation for load-side converter of BDFG in stand-alone operation
Authors:
- 1 September 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 1171-1177
Abstract
In this paper, a transient control method is proposed to compensate the reactive currents when the resistive-inductive load is suddenly connected to the power winding of the brushless doubly-fed generator (BDFG). Under stand-alone situation, the waveform of stator power winding voltage is strongly affected because of reactive power component of load. To tackle this problem, the load-side converter (LSC) works as a static var generator by injecting a reactive current at the point of common coupling (PCC) to compensate the reactive load. Hence, the LSC controller must determine the instantaneous value of the reference compensation current, according to the reactive component of the load current. This paper analyzes the transient-state of the load current when the load is suddenly connected to the BDFG, and proposes a compensation algorithm which has a good transient-state performance at the PCC. In addition, an improved reactive load current detection which does not rely on phase-locked loops is applied in this paper and the moving average (MVA) filter instead of traditional low-pass filter (LPF) is also used. So the control algorithm is simple and do not need more computation. The correctness of the proposed method is demonstrated by simulations and experiments.Keywords
This publication has 11 references indexed in Scilit:
- Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design GuidelinesIEEE Transactions on Power Electronics, 2014
- Improving the Reactive Power Capability of the DFIG-Based Wind Turbine During Operation Around the Synchronous SpeedIEEE Transactions on Energy Conversion, 2013
- Control Strategy for Harmonic Elimination in Stand-Alone DFIG Applications With Nonlinear LoadsIEEE Transactions on Power Electronics, 2011
- Frequency-Adaptive Stationary-Reference-Frame Grid Voltage Sequence Detector for Distributed Generation SystemsIEEE Transactions on Industrial Electronics, 2010
- Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction GeneratorsIEEE Transactions on Energy Conversion, 2007
- On Some Misinterpretations of the Instantaneous Reactive Power$phbox-q$TheoryIEEE Transactions on Power Electronics, 2004
- Harmonic current and reactive power compensation with an active filter2003
- A new algorithm for active shunt filters using instantaneous reactive power theoryIEEE Power Engineering Review, 2000
- DC voltage control and stability analysis of PWM-voltage-type reversible rectifiersIEEE Transactions on Industrial Electronics, 1998
- Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage ComponentsIEEE Transactions on Industry Applications, 1984