Deformation and fracture of K3 rotary nickel–titanium endodontic instruments after clinical use
- 20 November 2015
- journal article
- Published by Wiley in International Endodontic Journal
- Vol. 49 (11) , 1088-1094
Abstract
The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P < 0.003) except for 0.08 files (P > 0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use.Keywords
This publication has 15 references indexed in Scilit:
- Torsion and Bending Properties of OneShape and WaveOne InstrumentsJournal of Endodontics, 2015
- Comparative evaluation of the shaping ability of ProTaper Next, iRaCe and Hyflex CM rotary NiTi files in severely curved root canalsInternational Endodontic Journal, 2014
- Influence of curvature location along an artificial canal on cyclic fatigue of a rotary nickel-titanium endodontic instrumentOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2011
- Flexibility of K3 and ProTaper universal instrumentsBrazilian Dental Journal, 2011
- Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM studyJournal of Conservative Dentistry, 2011
- Influence of cyclic torsional loading on the fatigue resistance of K3 instrumentsInternational Endodontic Journal, 2008
- Dimensional characterization and mechanical behaviour of K3 rotary instrumentsInternational Endodontic Journal, 2008
- Comparison of Defects in ProFile and ProTaper Systems after Clinical UseJournal of Endodontics, 2006
- Defects in ProTaper S1 instruments after clinical use: fractographic examinationInternational Endodontic Journal, 2005
- The K3 rotary nickel–titanium file systemDental Clinics of North America, 2004