Xinmei Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xinmei Chen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Liwei Zheng
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Pediatric Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
3 shared publications Panpan Wang
State Key Laboratory of Oral Diseases, Sichuan University, Chengdu, Sichuan, China
2 shared publicationsXin Li
State Key Laboratory of Oral Diseases, Sichuan University, Chengdu, Sichuan, China
2 shared publicationsBilal Ahmed Sheikh
State Key Laboratory of Oral disease, National Clinical Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
1 shared publicationChangchun Zhou
State Key Laboratory of Oral disease, National Clinical Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
1 shared publication- D.X. Song
State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China; Department of Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
1 shared publication
Latest Publications
- Open Access
- 3 March 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1141631
Recent advances in 2D material-based phototherapy
Phototherapy, which generally refers to photothermal therapy (PTT) and photodynamic therapy (PDT), has received significant attention over the past few years since it is non-invasive, has effective selectivity, and has few side effects. As a result, it has become a promising alternative to traditional clinical treatments. At present, two-dimensional materials (2D materials) have proven to be at the forefront of the development of advanced nanomaterials due to their ultrathin structures and fascinating optical properties. As a result, much work has been put into developing phototherapy platforms based on 2D materials. This review summarizes the current developments in 2D materials beyond graphene for phototherapy, focusing on the novel approaches of PTT and PDT. New methods are being developed to go above and beyond conventional treatment to fully use the potential of 2D materials. Additionally, the efficacy of cutting-edge phototherapy is assessed, and the existing difficulties and future prospects of 2D materials for phototherapy are covered.
- 3 March 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1141631
Open AccessRecent advances in 2D material-based phototherapy
Phototherapy, which generally refers to photothermal therapy (PTT) and photodynamic therapy (PDT), has received significant attention over the past few years since it is non-invasive, has effective selectivity, and has few side effects. As a result, it has become a promising alternative to traditional clinical treatments. At present, two-dimensional materials (2D materials) have proven to be at the forefront of the development of advanced nanomaterials due to their ultrathin structures and fascinating optical properties. As a result, much work has been put into developing phototherapy platforms based on 2D materials. This review summarizes the current developments in 2D materials beyond graphene for phototherapy, focusing on the novel approaches of PTT and PDT. New methods are being developed to go above and beyond conventional treatment to fully use the potential of 2D materials. Additionally, the efficacy of cutting-edge phototherapy is assessed, and the existing difficulties and future prospects of 2D materials for phototherapy are covered.
- 20 November 2015
- Published by Wiley in International Endodontic Journal
- Vol. 49 (11) , 1088-1094
Deformation and fracture of K3 rotary nickel–titanium endodontic instruments after clinical use
The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P < 0.003) except for 0.08 files (P > 0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use.
- 20 November 2015
- Published by Wiley in International Endodontic Journal
- Vol. 49 (11) , 1088-1094
Deformation and fracture of K3 rotary nickel–titanium endodontic instruments after clinical use
The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P < 0.003) except for 0.08 files (P > 0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use.
- 18 September 2013
- Published by Elsevier in Toxicology in Vitro
- Vol. 27 (8) , 2149-2155
Cytotoxicity of ammonium hexafluorosilicate on human gingival fibroblasts
- 18 September 2013
- Published by Elsevier in Toxicology in Vitro
- Vol. 27 (8) , 2149-2155
Cytotoxicity of ammonium hexafluorosilicate on human gingival fibroblasts
- 9 June 2012
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 113 (11) , 867-871
Comprehensive dental treatment for “meth mouth”: A case report and literature review
- 9 June 2012
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 113 (11) , 867-871
Comprehensive dental treatment for “meth mouth”: A case report and literature review
- 9 January 2012
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 111 (2) , 55-56
Electrodeposited biomimetic hydroxyapaptite coating, a potential evolution for dentin hypersensitivity
- 9 January 2012
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 111 (2) , 55-56
Electrodeposited biomimetic hydroxyapaptite coating, a potential evolution for dentin hypersensitivity
- 1 April 2008
- Vol. 26 (2) , 183-5
[Investigation of influence on apical sealability generated by root canal sealer placement].
To investigate the influence of sealer placement on apical sealability in root canal treatment. 100 extracted single root canal teeth were selected. All canals were prepared by manual Protaper instrument in a step-back way. The samples were divided into 5 groups randomly. A group: 30 samples, sealer placement by chief gutta percha; B group: 30 samples, sealer placement by K file; C group: 30 samples, sealer placement by spreader; D group: 5 samples, a positive control; E group: 5 samples, a negative control. There were 2 subsets in each experimental group which were obturated by lateral gutta percha with or without sealer. Glucose oxidase method was used to measure the apical leakage at the 1st 2nd, 4th, 7th, 10th, 15th, 20th, 25th, 30th day of the experiment. Apical sealability varied with different sealer placement methods (F=4.832, P=0.001). Sealer placement by chief gutta percha (A group) had the best instant apical sealability. However, lateral gutta percha with or without sealer didn't affect the apical sealibility. Placing the same kind sealer in different ways can affect the apical sealability. There were no significant differences of the apical leakage no matter the lateral gutta percha with or without sealer. In order to get better instant apical sealability and simplify the clinic operation, placing the sealer with a chief gutta percha while the lateral gutta percha without sealer is recommended.
- 1 April 2008
- Vol. 26 (2) , 183-5
[Investigation of influence on apical sealability generated by root canal sealer placement].
To investigate the influence of sealer placement on apical sealability in root canal treatment. 100 extracted single root canal teeth were selected. All canals were prepared by manual Protaper instrument in a step-back way. The samples were divided into 5 groups randomly. A group: 30 samples, sealer placement by chief gutta percha; B group: 30 samples, sealer placement by K file; C group: 30 samples, sealer placement by spreader; D group: 5 samples, a positive control; E group: 5 samples, a negative control. There were 2 subsets in each experimental group which were obturated by lateral gutta percha with or without sealer. Glucose oxidase method was used to measure the apical leakage at the 1st 2nd, 4th, 7th, 10th, 15th, 20th, 25th, 30th day of the experiment. Apical sealability varied with different sealer placement methods (F=4.832, P=0.001). Sealer placement by chief gutta percha (A group) had the best instant apical sealability. However, lateral gutta percha with or without sealer didn't affect the apical sealibility. Placing the same kind sealer in different ways can affect the apical sealability. There were no significant differences of the apical leakage no matter the lateral gutta percha with or without sealer. In order to get better instant apical sealability and simplify the clinic operation, placing the sealer with a chief gutta percha while the lateral gutta percha without sealer is recommended.