NEAR-CONTINUOUS, NONINVASIVE BLOOD PRESSURE MONITORING IN THE OUT-OF-HOSPITAL SETTING
- 1 January 2005
- journal article
- research article
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 9 (1) , 68-72
Abstract
Objectives. This study was conducted to test out-of-hospital performance of a noninvasive radial artery tonometry device to assess blood pressure (BP), providing readings every 10–12 seconds. The primary objective was to determine the correlation between noninvasive BPs calculated with radial artery tonometry andstandard oscillometric cuff methods. The secondary objective was to determine whether the difference observed between the two techniques was consistent over the range of BPs measured. Methods. This prospective trial enrolled adults transported by helicopter (n = 9 patients), fixed-wing airplane (n = 1), or ground vehicle (n = 10) of a single transport service. Patients had BP assessed simultaneously, by both standard automatic cuff andradial artery tonometry device, every 5 minutes. Data were assessed with correlation coefficients, andBland-Altman techniques were utilized to assess for bias over the range of mean arterial pressures (MAPs) encountered. For all tests, p was set at 0.05. Results. No major problem with radial artery tonometry device field performance was noted. There were 139 pairs of MAP assessments in 20 patients. The correlation coefficient for the two assessment modalities was 0.96. Bland-Altman bias plot andPitman's test (p = 0.11) revealed good correlation between the two assessment mechanisms over the entire range of MAPs (42 to 163 mm Hg) encountered in the study. Conclusion. The radial artery tonometry device provided MAP assessments that were highly correlated with readings from a standard oscillometric device. The radial artery tonometry device performed well in a variety of patient types andin multiple transport vehicles, andthere was no sign that its performance was adversely affected by the out-of-hospital setting.Keywords
This publication has 10 references indexed in Scilit:
- Use of a radial artery compression device for noninvasive, near-continuous blood pressure monitoring in the EDThe American Journal of Emergency Medicine, 2004
- Nontraumatic out-of-hospital hypotension predicts inhospital mortalityAnnals of Emergency Medicine, 2004
- Are Automated Blood Pressure Measurements Accurate in Trauma Patients?2003
- Isolated prehospital hypotension after traumatic injuries: a predictor of mortality?The Journal of Emergency Medicine, 2003
- Management of Suspected Aortic Dissection During Interfacility Transport: Opportunity for Beneficial Intervention by the Critical Care Transport CreChest, 2003
- Damage control: past, present, and future of prehospital stroke managementEmergency Medicine Clinics of North America, 2002
- Resuscitation of Blood Pressure and OxygenationJournal of Neurotrauma, 2000
- A New Noninvasive Method to Measure Blood PressureAnesthesiology, 1999
- Accuracy of radial artery blood pressure determination with the Vasotrac™Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 1999
- Practice parameters for hemodynamic support of sepsis in adult patients in sepsisCritical Care Medicine, 1999