Stephen H. Thomas
Research Subjects
Stephen H. Thomas has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Suzanne K. Wedel
2 shared publicationsBlair Parry
Department of Emergency Services, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts
1 shared publicationChristine Kociszewski
1 shared publicationGreg Winsor
Boston MedFlight, Boston, Massachusetts
1 shared publicationPaul J. Brennan
1 shared publication- Peter S. Pang
Department of Emergency Medicine, Indiana University School of Medicine, Indianapolis, USA
1 shared publication
Latest Publications
- 1 September 2006
- Published by Wolters Kluwer Health in Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine
- Vol. 5 (3) , 155-159
Prehospital Electrocardiogram and Early Helicopter Dispatch to Expedite Interfacility Transfer for Percutaneous Coronary Intervention
Care provision and benchmarking for patients with ST-elevation myocardial infarction (STEMI) have focused on streamlining time between initial hospital presentation and opening of theinfarct-related artery. In a Boston-area regional system already characterized by expedited advanced life support (ALS) dispatch and paramedic performance of prehospital electrocardiogram (EKG), a critical pathway was designed that allows for helicopter dispatch based on ground ALS providers' STEMI diagnosis. The pathway dictates that as soon as ALS crews make the diagnosis of STEMI from their 12-lead EKG, they will contact Boston MedFlight (BMF) and a helicopter will be immediately dispatched to the participating community hospital (Lawrence General Hospital [LGH]). Based on historical and predicted time patterns, it is expected that BMF will arrive at LGH soon after the ALS ambulance delivers the patient to the LGH emergency department (ED). The patient will then undergo BMF transport from the ED into central Boston with direct transfer into an awaiting cardiac catheterization suite (ie, bypassing the receiving hospital ED). The pathway minimizes the delay between patient arrival at LGH and BMF arrival for transport to the catheterization laboratory. It is hoped that implementation of the critical pathway will allow the region's patients with STEMI to achieve coronary arterial patency within 90 minutes of LGH presentation. If the pathway proves effective, it can serve as a model for other regions and programs with similar clinical and logistic situations and advance the concept of "diagnosis-to-balloon" time.
- 1 September 2006
- Published by Wolters Kluwer Health in Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine
- Vol. 5 (3) , 155-159
Prehospital Electrocardiogram and Early Helicopter Dispatch to Expedite Interfacility Transfer for Percutaneous Coronary Intervention
Care provision and benchmarking for patients with ST-elevation myocardial infarction (STEMI) have focused on streamlining time between initial hospital presentation and opening of theinfarct-related artery. In a Boston-area regional system already characterized by expedited advanced life support (ALS) dispatch and paramedic performance of prehospital electrocardiogram (EKG), a critical pathway was designed that allows for helicopter dispatch based on ground ALS providers' STEMI diagnosis. The pathway dictates that as soon as ALS crews make the diagnosis of STEMI from their 12-lead EKG, they will contact Boston MedFlight (BMF) and a helicopter will be immediately dispatched to the participating community hospital (Lawrence General Hospital [LGH]). Based on historical and predicted time patterns, it is expected that BMF will arrive at LGH soon after the ALS ambulance delivers the patient to the LGH emergency department (ED). The patient will then undergo BMF transport from the ED into central Boston with direct transfer into an awaiting cardiac catheterization suite (ie, bypassing the receiving hospital ED). The pathway minimizes the delay between patient arrival at LGH and BMF arrival for transport to the catheterization laboratory. It is hoped that implementation of the critical pathway will allow the region's patients with STEMI to achieve coronary arterial patency within 90 minutes of LGH presentation. If the pathway proves effective, it can serve as a model for other regions and programs with similar clinical and logistic situations and advance the concept of "diagnosis-to-balloon" time.
- 1 January 2005
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 9 (1) , 68-72
NEAR-CONTINUOUS, NONINVASIVE BLOOD PRESSURE MONITORING IN THE OUT-OF-HOSPITAL SETTING
Objectives. This study was conducted to test out-of-hospital performance of a noninvasive radial artery tonometry device to assess blood pressure (BP), providing readings every 10–12 seconds. The primary objective was to determine the correlation between noninvasive BPs calculated with radial artery tonometry andstandard oscillometric cuff methods. The secondary objective was to determine whether the difference observed between the two techniques was consistent over the range of BPs measured. Methods. This prospective trial enrolled adults transported by helicopter (n = 9 patients), fixed-wing airplane (n = 1), or ground vehicle (n = 10) of a single transport service. Patients had BP assessed simultaneously, by both standard automatic cuff andradial artery tonometry device, every 5 minutes. Data were assessed with correlation coefficients, andBland-Altman techniques were utilized to assess for bias over the range of mean arterial pressures (MAPs) encountered. For all tests, p was set at 0.05. Results. No major problem with radial artery tonometry device field performance was noted. There were 139 pairs of MAP assessments in 20 patients. The correlation coefficient for the two assessment modalities was 0.96. Bland-Altman bias plot andPitman's test (p = 0.11) revealed good correlation between the two assessment mechanisms over the entire range of MAPs (42 to 163 mm Hg) encountered in the study. Conclusion. The radial artery tonometry device provided MAP assessments that were highly correlated with readings from a standard oscillometric device. The radial artery tonometry device performed well in a variety of patient types andin multiple transport vehicles, andthere was no sign that its performance was adversely affected by the out-of-hospital setting.
- 1 January 2005
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 9 (1) , 68-72
NEAR-CONTINUOUS, NONINVASIVE BLOOD PRESSURE MONITORING IN THE OUT-OF-HOSPITAL SETTING
Objectives. This study was conducted to test out-of-hospital performance of a noninvasive radial artery tonometry device to assess blood pressure (BP), providing readings every 10–12 seconds. The primary objective was to determine the correlation between noninvasive BPs calculated with radial artery tonometry andstandard oscillometric cuff methods. The secondary objective was to determine whether the difference observed between the two techniques was consistent over the range of BPs measured. Methods. This prospective trial enrolled adults transported by helicopter (n = 9 patients), fixed-wing airplane (n = 1), or ground vehicle (n = 10) of a single transport service. Patients had BP assessed simultaneously, by both standard automatic cuff andradial artery tonometry device, every 5 minutes. Data were assessed with correlation coefficients, andBland-Altman techniques were utilized to assess for bias over the range of mean arterial pressures (MAPs) encountered. For all tests, p was set at 0.05. Results. No major problem with radial artery tonometry device field performance was noted. There were 139 pairs of MAP assessments in 20 patients. The correlation coefficient for the two assessment modalities was 0.96. Bland-Altman bias plot andPitman's test (p = 0.11) revealed good correlation between the two assessment mechanisms over the entire range of MAPs (42 to 163 mm Hg) encountered in the study. Conclusion. The radial artery tonometry device provided MAP assessments that were highly correlated with readings from a standard oscillometric device. The radial artery tonometry device performed well in a variety of patient types andin multiple transport vehicles, andthere was no sign that its performance was adversely affected by the out-of-hospital setting.