Two-effective-source method for the calculation of in-air output at various source-to-detector distances in wedged fields
Authors:
- Siyong KimSKSiyong Kim
- Chihray LiuCLChihray Liu
- Cody ChenCCCody Chen
- Jatinder R. PaltaJPJatinder R. Palta
- 7 June 1999
- journal article
- Published by Wiley in Medical Physics
- Vol. 26 (6) , 949-955
Abstract
A simple algorithm was developed for calculation of the in-air output at various source-to-detector distances (SDDs) on the central axis for wedged fields. In the algorithm we dealt independently with two effective sources, one for head scatter and the other for wedge scatter. Varian 2100C with 18 and 8 MV photon beams was used to examine this algorithm. The effective source position for head scatter for wedged fields was assumed to be the same as that for open fields, and the effective source position for wedge scatter was assumed to be a certain distance upstream from the physical location of the wedge. The shift of the effective source for wedge scatter, w, was found to be independent of field size. Moreover, we observed no systematic dependency of w on wedge angle or beam energy. One value, w = 5.5 cm, provided less than 1% difference in in-air outputs through the whole experimental range, i.e., 6 x 6 to 20 x 20 cm2 field size (15 x 20 cm2 for 60 degrees wedge), 15 degrees-60 degrees wedge angle, 80-130 cm SDD, and both 18 and 8 MV photon beams. This algorithm can handle the case in which use of a tertiary collimator with an external wedge makes the field size for the determination of wedge scatter different from that for head scatter. In this case, without the two-effective-source method, the maximum of 4.7% and 2.6% difference can be given by the inverse square method and one-effective-source method in a 45 degrees wedged field with 18 MV. Differences can be larger for thicker wedges. Enhanced dynamic wedge (EDW) fields were also examined. It was found that no second effective source is required for EDW fields.Keywords
This publication has 21 references indexed in Scilit:
- Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source modelMedical Physics, 1996
- A Monte Carlo study of accelerator head scatterMedical Physics, 1994
- Analytic modeling of photon scatter from flattening filters in photon therapy beamsMedical Physics, 1994
- On the field-size dependence of relative output from a linear acceleratorMedical Physics, 1992
- Application of the convolution method for calculation of output factors for therapy photon beamsMedical Physics, 1992
- The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantomRadiotherapy and Oncology, 1991
- Output factor constituents of a high‐energy photon beamMedical Physics, 1988
- The effect of collimator backscatter radiation on photon output of linear acceleratorsMedical Physics, 1987
- Head scatter data for several linear accelerators (4-18 MV)Medical Physics, 1986
- Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear AcceleratorMedical Physics, 1981