Abstract
Personalized dosimetry in computed tomography (CT) can be realized by a full Monte Carlo (MC) simulation of the scan procedure. Essential input data needed for the simulation are appropriate CT x-ray source models and a model of the patients body which is based on the CT image. The purpose of this work is to develop comprehensive procedures for the determination of CT x-ray source models and their verication by comparison of calculated and measured dose distributions in physical phantoms. Mobile equipment together with customized software was developed and used for non-invasive determination of equivalent source models of CT scanners under clinical conditions. Standard and physical anthropomorphic CT dose phantoms equipped with real-time CT dose probes at five representative positions were scanned. The accumulated dose was measured during the scan at the five positions. ImpactMC, a MC-based CT dose software program, was used to simulate the scan. The necessary inputs were obtained from the scan parameters, from the equivalent source models and from the material-segmented CT images of the phantoms. 3D dose distributions in the phantoms were simulated and the dose values calculated at the five positions inside the phantom were compared to measured dose values. Initial results were obtained by means of a General Electric Optima CT 660 and a Toshiba (Canon) Aquilion ONE. In general, the measured and calculated dose values were within relative uncertainties that had been estimated to be less than 10 %. The procedures developed were found to be viable and rapid. The procedures are applicable to any scanner type under clinical conditions without making use of the service mode with stationary x-ray tube position. Results show that the procedures are well suited for determining and verifying the equivalent source models needed for personalized CT dosimetry based on post-scan MC calculations.Keywords
Funding Information
- European Metrology Programme for Innovation and Research (EMPIR 15HLT05)
This publication has 34 references indexed in Scilit:
- Dose in x-ray computed tomographyPhysics in Medicine & Biology, 2014
- Real-time dosimeter employed to evaluate the half-value layer in CTPhysics in Medicine & Biology, 2013
- CT Dose Index and Patient Dose: They AreNotthe Same ThingRadiology, 2011
- Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length ProductRadiology, 2010
- SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubesPhysics in Medicine & Biology, 2009
- Evaluation of a patient-specific Monte Carlo software for CT dosimetryRadiation Protection Dosimetry, 2009
- Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomographyEuropean Radiology, 2007
- Monte Carlo simulation of a computed tomography x-ray tubePhysics in Medicine & Biology, 2007
- CT Dose Reduction and Dose Management Tools: Overview of Available OptionsRadioGraphics, 2006
- Measurement of absolute energy spectra from a clinical CT machine under working conditions using a Compton spectrometerPhysics in Medicine & Biology, 1989