    CT beam dosimetric characterization procedure for personalized dosimetry

    by S Rosendahl, L Büermann, M Borowski, M Kortesniemi, V-M Sundell, A Kosunen, T Siiskonen

    Personalized dosimetry in computed tomography (CT) can be realized by a full Monte Carlo (MC) simulation of the scan procedure. Essential input data needed for the simulation are appropriate CT x-ray source models and a model of the patients body which is based on the CT image. The purpose of this work is to develop comprehensive procedures for the determination of CT x-ray source models and their verication by comparison of calculated and measured dose distributions in physical phantoms. Mobile equipment together with customized software was developed and used for non-invasive determination of equivalent source models of CT scanners under clinical conditions. Standard and physical anthropomorphic CT dose phantoms equipped with real-time CT dose probes at five representative positions were scanned. The accumulated dose was measured during the scan at the five positions. ImpactMC, a MC-based CT dose software program, was used to simulate the scan. The necessary inputs were obtained from the scan parameters, from the equivalent source models and from the material-segmented CT images of the phantoms. 3D dose distributions in the phantoms were simulated and the dose values calculated at the five positions inside the phantom were compared to measured dose values. Initial results were obtained by means of a General Electric Optima CT 660 and a Toshiba (Canon) Aquilion ONE. In general, the measured and calculated dose values were within relative uncertainties that had been estimated to be less than 10 %. The procedures developed were found to be viable and rapid. The procedures are applicable to any scanner type under clinical conditions without making use of the service mode with stationary x-ray tube position. Results show that the procedures are well suited for determining and verifying the equivalent source models needed for personalized CT dosimetry based on post-scan MC calculations.


  • Open Access

    Comprehensive procedure for personalized dosimetry in computed tomography

    by Stephan Rosendahl, Ludwig Büermann, Markus Borowski, Mika Kortesniemi, Antti Kosunen, Teemu Siiskonen, Veli-Matti Sundell

    The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was developed and used for rapid, non-invasive determination of equivalent source models of CT scanners under clinical conditions. Standard and anthropomorphic CT dose phantoms equipped with real-time CT dose probes at five representative positions were scanned. The accumulated dose was measured during the scan at the five positions. ImpactMC, a Monte Carlo-based CT dose software program, was used to simulate the scan. The necessary inputs were obtained from the scan parameters, from the equivalent source models and from the material-segmented CT images of the phantoms. Post-scan 3D dose distributions in the phantoms were simulated and the dose values calculated at the five positions inside the phantom were compared to measured dose values. Initial results were obtained by means of a General Electric Optima CT 660 and a Toshiba (Canon) Aquilion ONE. In general, the measured and calculated dose values were within relative uncertainties that had been estimated to be less than 10%. The procedures developed, which allow the post-CT scan dose to be measured and calculated at five points inside anthropomorphic phantoms, were found to be viable and rapid. The procedures are applicable to any scanner type under clinical conditions. Results show that the procedures are well suited for verifying the applicability of personalized CT dosimetry based on post-scan Monte Carlo calculations.

  • Open Access

    Dynamic determination of equivalent CT source models for personalized dosimetry

    by Stephan Rosendahl, Ludwig Büermann

    With improvements in CT technology, the need for reliable patient-specific dosimetry increased in the recent years. The accuracy of Monte-Carlo simulations for absolute dose estimation is related to scanner specific information on the X-ray spectra of the scanner as well as the form filter geometries and compositions. In this work a mobile measurement setup is developed, which allows both to determine the X-ray spectra and equivalent form filter of a specific scanner from just one helical scan in less than 2 minutes.


  • Open Access

    Determination of lead equivalent values according to IEC 61331-1:2014—Report and short guidelines for testing laboratories

    by L. Büermann

    Materials used for the production of protective devices against diagnostic medical Xradiation described in the international standard IEC 61331-3 need to be specified in terms of their lead attenuation equivalent thickness according to the methods described in IEC 61331-1. In May 2014 the IEC published the second edition of these standards which contain improved methods for the determination of attenuation ratios and the corresponding lead attenuation equivalent thicknesses of lead-reduced or lead-free materials. These methods include the measurement of scattered photons behind the protective material which were hitherto neglected but are becoming more important because of the increasing use of lead-reduced or even lead-free materials. They can offer the same protective effect but are up to 20% lighter and also easier to dispose of. The new method is based on attenuation ratios measured with the so-called "inverse broad beam condition". Since the corresponding measurement procedure is new and in some respects more complex than the methods used in the past, it was regarded as being helpful to have a description of how such measurements can reliably be performed. This technical report describes in detail the attenuation ratio measurements and corresponding procedures for the lead equivalent determinations of sample materials using the method with the inverse broad beam condition as carried out at the Physikalisch-Technische Bundesanstalt (PTB). PTB still offers material testing and certification for the German responsible notified body. In addition to the description of the measurements at PTB, a short technical guide is provided for testing laboratories which intend to establish this kind of protective material certification. The guide includes technical recommendations for the testing equipment like X-ray facilities, reference lead sheets and radiation detectors; special procedures for the determination of the lead attenuation equivalent thickness; their uncertainties and the necessary contents of the test certificate.


  • Measurement of the x-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiation

    by L Büermann, B Grosswendt, H-M Kramer, H-J Selbach, M Gerlach, M Hoffmann, M Krumrey

    For the first time absolute photon mass energy-absorption coefficients of air in the energy range 3 keV to 10 keV have been measured with relative standard uncertainties less than 1%, significantly smaller than those of up to 5% assumed hitherto for calculated data. Monochromatized synchrotron radiation was used to measure both the total radiant energy by means of silicon photodiodes calibrated against a cryogenic radiometer and the fraction of radiant energy that is deposited in dry air by means of a free air ionization chamber. The measured ionization charge was converted into energy absorbed in air by calculated effective W values of photons as a function of their energy based on new measurements of the W values in dry air for electron kinetic energies between 1 keV and 7 keV, also presented in this work. The measured absorption coefficients were compared with state-of-the art calculations and found to agree within 0.7% with data calculated earlier by Hubbell at energies above 4 keV but were found to differ by values up to 2.1% at 10 keV from more recent calculations of Seltzer.


  • Is there reliable experimental evidence for different dicentric yields in human lymphocytes produced by mammography X-rays free-in-air and within a phantom?

    by L. Büermann, M. Krumrey, M. Haney, E. Schmid

    We examined the production of dicentrics in human lymphocytes irradiated with 29 kV X-rays to a depth of 13.5 mm in a PMMA phantom. For these irradiation conditions, which are appropriate for the diagnostic application of mammography X-rays, a coefficient α of (5.88±0.66)×10−2 Gy−1 of the linear quadratic dose–response relationship was determined. This value does not differ significantly from the coefficient α of (6.55±0.97)×10−2 Gy−1 obtained earlier for a free-in-air set-up using blood of the same donor. The results are interpreted in terms of both the energy distributions of the photon fluence of mammography X-rays free-in-air and those in the PMMA phantom. Based on earlier results of experiments with monochromatic X-rays in the energy range 1.83–40 keV (completed here by an additional measurement at 25 keV), a fit function α(E) to the measured α coefficients as a function of the energy E of monochromatic X-rays was used to calculate weighted mean values \(\bar \alpha\) for both the mammography X-ray spectra free-in-air and in the phantom. As a result, weighted mean values of (4.9±1.0)×10−2 Gy−1 and (4.5±1.0)×10−2 Gy−1 were obtained, respectively. Although the measured α coefficients for mammography X-rays appear to be systematically higher than those calculated as weighted mean values \(\bar \alpha\), it can be concluded that the modification of the mammography X-ray spectrum to a depth of 13.5 mm in a PMMA phantom compared with the free-in-air spectrum has no significant influence on the dicentric yields in human lymphocytes.


  • Results supporting calculated wall correction factors for cavity chambers

    by L Büermann, H-M Kramer, I Csete

    Thick walled cavity ionization chambers are used by primary standard laboratories as primary air kerma standards in 137Cs and 60Co γ-rays. Application of the cavity theory requires correction for the effects of photon attenuation and scattering in the chamber walls. For more than a decade there have been intensive discussions about the validity of wall correction factors determined by more traditional extrapolation methods versus those calculated by Monte Carlo methods. For existing primary standards the alternative methods lead to results that differ by up to 50% of the correction itself. This report presents both experimental and theoretical results which strongly support the validity of calculated wall correction factors. Moreover, it is demonstrated that, in selected cases, the application of a linear extrapolation method leads to errors in the determination of the air kerma reaching up to 13%.