Time-resolved tracking of the atrioventricular plane displacement in Cardiovascular Magnetic Resonance (CMR) images
Authors:
- Felicia SeemannFSFelicia Seemann
- Ulrika PahlmUPUlrika Pahlm
- Katarina Steding-EhrenborgKSKatarina Steding-Ehrenborg
- Ellen OstenfeldEOEllen Ostenfeld
- David ErlingeDEDavid Erlinge
- Jean-Luc Dubois-RandeJDJean-Luc Dubois-Rande
- Svend Eggert JensenSJSvend Eggert Jensen
- Dan AtarDADan Atar
- Håkan ArhedenHAHåkan Arheden
- Marcus CarlssonMCMarcus Carlsson
- Einar HeibergEHEinar Heiberg
Open Access
- 28 February 2017
- journal article
- research article
- Published by Springer Nature in BMC Medical Imaging
- Vol. 17 (1) , 1-16
Abstract
Atrioventricular plane displacement (AVPD) is an indicator for systolic and diastolic function and accounts for 60% of the left ventricular, and 80% of the right ventricular stroke volume. AVPD is commonly measured clinically in echocardiography as mitral and tricuspid annular plane systolic excursion (MAPSE and TAPSE), but has not been applied widely in cardiovascular magnetic resonance (CMR). To date, there is no robust automatic algorithm available that allows the AVPD to be measured clinically in CMR with input in a single timeframe. This study aimed to develop, validate and provide a method that automatically tracks the left and right ventricular AVPD in CMR images, which can be used in the clinical setting or in applied cardiovascular research in multi-center studies. The proposed algorithm is based on template tracking by normalized cross-correlation combined with a priori information by principal component analysis. The AVPD in each timeframe is calculated for the left and right ventricle separately using CMR long-axis cine images of the 2, 3, and 4-chamber views. The algorithm was developed using a training set (n = 40), and validated in a test set (n = 113) of healthy subjects, athletes, and patients after ST-elevation myocardial infarction from 10 centers. Validation was done using manual measurements in end diastole and end systole as reference standard. Additionally, AVPD, peak emptying velocity, peak filling velocity, and atrial contraction was validated in 20 subjects, where time-resolved manual measurements were used as reference standard. Inter-observer variability was analyzed in 20 subjects. In end systole, the difference between the algorithm and the reference standard in the left ventricle was (mean ± SD) -0.6 ± 1.9 mm (R = 0.79), and −0.8 ± 2.1 mm (R = 0.88) in the right ventricle. Inter-observer variability in end systole was −0.6 ± 0.7 mm (R = 0.95), and −0.5 ± 1.4 mm (R = 0.95) for the left and right ventricle, respectively. Validation of peak emptying velocity, peak filling velocity, and atrial contraction yielded lower accuracy than the displacement measures. The proposed algorithm show good agreement and low bias with the reference standard, and with an agreement in parity with inter-observer variability. Thus, it can be used as an automatic method of tracking and measuring AVPD in CMR.Keywords
Funding Information
- Vetenskapsrådet (2012-4944)
- Hjärt-Lungfonden (20140624)
- Region of Scania
- Seventh Framework Programme (HEALTH-2010-261034)
- Novo Nordisk
- Svenska Hjärtföbundet
This publication has 39 references indexed in Scilit:
- Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post ProcessingJournal of Cardiovascular Magnetic Resonance, 2013
- Relation between cardiac dimensions and peak oxygen uptakeJournal of Cardiovascular Magnetic Resonance, 2010
- Design and validation of Segment - freely available software for cardiovascular image analysisBMC Medical Imaging, 2010
- Left and right ventricular long-axis function and prognosisHeart, 2008
- The quantitative relationship between longitudinal and radial function in left, right, and total heart pumping in humansAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Atrioventricular plane displacement is the major contributor to left ventricular pumping in healthy adults, athletes, and patients with dilated cardiomyopathyAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Automated mitral annular tracking: A novel method for evaluating mitral annular motion using two-dimensional echocardiographyJournal of the American Society of Echocardiography, 2005
- Duration of diastole and its phases as a function of heart rate during supine bicycle exerciseAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Total heart volume variation throughout the cardiac cycle in humansAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986