Arthroscopic cam resection reduces femoroacetabular contact pressure
Authors:
Open Access
- 21 November 2025
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (11) , 1053-1063
Abstract
Aims: Arthroscopic cam resection in femoroacetabular impingement syndrome leads to clinical improvement, but biomechanical studies on the effect of surgical intervention are scarce. In this study, we compared the femoroacetabular contact pressure (CP) in an intact cam morphology and after arthroscopic cam resection. The hypothesis was that arthroscopic cam resection decreases the femoroacetabular CP. Methods: A cadaveric study was performed on nine hips with a cam morphology (α angle > 60°). CP was assessed using a new hip-specific device and an intracranial pressure (ICP) sensor. These evaluations were performed during hip arthroscopy, in the intact joint and after cam resection, with the joint in different positions. These measurements were normalized and reported as a percentage of the native intact joint. Results: A statistically significant difference in the mean CP measured with the hip-specific device was observed before and after cam osteoplasty at 0° (41.2% (SD 29.7%); p = 0.014), 30° (54.5% (SD 16.6%); p = 0.011), 60° (39.8% (SD 23.0%); p < 0.001), 80° of flexion (36.3% (SD 22.1%); p < 0.001), and 80° of flexion with 20° of internal rotation (26.0% (SD 22.4%); p < 0.001). The ICP sensor is very fragile and difficult to handle in hip arthroscopy. Consequently, we limited the evaluations using this sensor to five hips. A statistically significant difference in the CP was found before and after cam osteoplasty at 80° of flexion (57.6% (SD 29.1%); p = 0.004). Conclusion: This biomechanical study evaluated a new hip-specific device to intraoperatively measure the CP in arthroscopic surgery. It showed a significant decrease in the CP after arthroscopic cam resection with the joint in different positions. At 80° of flexion with 20° of internal rotation, a typical position to detect hip impingement, the CP was reduced to 26% after arthroscopic cam resection. The intraoperative measurement of CP provides surgeons with feedback to evaluate the effectiveness of the osteoplasty. Cite this article: Bone Joint Res 2025;14(11):1053–1063.Keywords
This publication has 45 references indexed in Scilit:
- Hip arthroscopy with initial access to the peripheral compartment provides significant improvement in FAI patientsKnee Surgery, Sports Traumatology, Arthroscopy, 2021
- The Lisbon Agreement on Femoroacetabular Impingement Imaging—part 1: overviewEuropean Radiology, 2020
- Basic Concepts in Hip Arthroscopy2017
- Residual Deformity Is the Most Common Reason for Revision Hip Arthroscopy: A Three-dimensional CT StudyClinical Orthopaedics and Related Research, 2015
- Establishing the radiation risk from fluoroscopic-assisted arthroscopic surgery of the hipInternational Orthopaedics, 2012
- Intraoperative Fluoroscopy for Evaluation of Bony Resection During Arthroscopic Management of Femoroacetabular Impingement in the Supine PositionArthroscopy, 2009
- Radiologic and Intraoperative Findings in Revision Hip ArthroscopyArthroscopy, 2007
- Contact study of the hip jointArchives of orthopaedic and trauma surgery, 1984
- Eine Abgrenzung normaler und dysplastischer jugendlicher H ftgelenke durch den H ftwertArchives of orthopaedic and trauma surgery, 1972
- Eine neue Methode zur r ntgenologischen Beurteilung eines H ftgelenkes ? Der H ftwertArchives of orthopaedic and trauma surgery, 1972