Pedro Dantas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pedro Dantas has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Vasco V. Mascarenhas
Musculoskeletal Imaging Unit, Imaging Center, Radiology Department, Hospital da Luz, Grupo Luz Saúde, Lisbon, Portugal
9 shared publications - Paulo Rego
Orthopaedic Department, Hospital Beatriz Ângelo, Loures, Portugal
6 shared publications - José Guimarães Consciência
Nova Medical School, Lisbon, Portugal
5 shared publications - Oliver Marín-Peña
Hospital Universitario Infanta Leonor
4 shared publications Olufemi R. Ayeni
Division of Orthopaedic Surgery, McMaster University, Hamilton, Ontario, Canada
4 shared publications- Sérgio Rodrigues Gonçalves
Hospital CUF Descobertas, Department of Orthopaedic Surgery, Lisbon, Lisbon, Portugal
4 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 11 (7) , 696-709
THA for DDH: replacement principles and techniques – acetabular side
- 1 July 2026
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 11 (7) , 696-709
Open AccessTHA for DDH: replacement principles and techniques – acetabular side
- 2 May 2026
- Published by Springer Nature
- p. 1095-1111
Management of Extra-Articular Hip Disorders: Hamstring Pathology
- 2 May 2026
- Published by Springer Nature
- p. 1095-1111
Management of Extra-Articular Hip Disorders: Hamstring Pathology
- Open Access
- 1 May 2026
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 11 (5) , 404-414
‘THA for DDH: replacement principles and techniques – femoral side’
Developmental dysplasia of the hip (DDH) remains a leading cause of early hip osteoarthritis and poses considerable technical challenges during total hip arthroplasty. Existing classification systems focus on the abnormal relationship between the femoral head and the acetabulum without emphasising the femoral morphological variations, which are equally significant in surgical planning. Dysplastic femora often demonstrate excessive neck anteversion, variable neck–shaft angles, reduced offset, and metaphyseal–diaphyseal mismatch with narrow intramedullary canals. These anatomical variations often compromise the abductor mechanism and alter hip biomechanics. Thorough preoperative planning is crucial and should include the evaluation of leg-length discrepancy, reconstruction of the hip centre of rotation, assessment of femoral version and canal morphology, implant selection, and consideration of femoral shortening osteotomy. Computed tomography-based planning can enhance preoperative planning in complex cases. Both cemented and cementless stems align with positive findings in DDH patients. Cemented stems enable reliable version control, decrease intraoperative fracture risk, and may be beneficial for patients with poor bone quality. In mild cases, most uncemented stems are suitable. More severe deformities necessitate specialised implant designs with conical fluted stems, which provide strong fixation and excellent long-term survivorship. Modular and custom-made options also achieve favourable outcomes in high-grade deformities. Femoral shortening osteotomies are often needed to restore biomechanics, correct abnormal version, and prevent nerve injury during reduction. The subtrochanteric osteotomy has been linked with excellent results in treating severe DDH. High-quality research is essential to deepen our understanding of proximal femur morphological abnormalities and to enhance surgical results.
- 1 May 2026
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 11 (5) , 404-414
Open Access‘THA for DDH: replacement principles and techniques – femoral side’
Developmental dysplasia of the hip (DDH) remains a leading cause of early hip osteoarthritis and poses considerable technical challenges during total hip arthroplasty. Existing classification systems focus on the abnormal relationship between the femoral head and the acetabulum without emphasising the femoral morphological variations, which are equally significant in surgical planning. Dysplastic femora often demonstrate excessive neck anteversion, variable neck–shaft angles, reduced offset, and metaphyseal–diaphyseal mismatch with narrow intramedullary canals. These anatomical variations often compromise the abductor mechanism and alter hip biomechanics. Thorough preoperative planning is crucial and should include the evaluation of leg-length discrepancy, reconstruction of the hip centre of rotation, assessment of femoral version and canal morphology, implant selection, and consideration of femoral shortening osteotomy. Computed tomography-based planning can enhance preoperative planning in complex cases. Both cemented and cementless stems align with positive findings in DDH patients. Cemented stems enable reliable version control, decrease intraoperative fracture risk, and may be beneficial for patients with poor bone quality. In mild cases, most uncemented stems are suitable. More severe deformities necessitate specialised implant designs with conical fluted stems, which provide strong fixation and excellent long-term survivorship. Modular and custom-made options also achieve favourable outcomes in high-grade deformities. Femoral shortening osteotomies are often needed to restore biomechanics, correct abnormal version, and prevent nerve injury during reduction. The subtrochanteric osteotomy has been linked with excellent results in treating severe DDH. High-quality research is essential to deepen our understanding of proximal femur morphological abnormalities and to enhance surgical results.
- Open Access
- 21 November 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (11) , 1053-1063
Arthroscopic cam resection reduces femoroacetabular contact pressure
Aims: Arthroscopic cam resection in femoroacetabular impingement syndrome leads to clinical improvement, but biomechanical studies on the effect of surgical intervention are scarce. In this study, we compared the femoroacetabular contact pressure (CP) in an intact cam morphology and after arthroscopic cam resection. The hypothesis was that arthroscopic cam resection decreases the femoroacetabular CP. Methods: A cadaveric study was performed on nine hips with a cam morphology (α angle > 60°). CP was assessed using a new hip-specific device and an intracranial pressure (ICP) sensor. These evaluations were performed during hip arthroscopy, in the intact joint and after cam resection, with the joint in different positions. These measurements were normalized and reported as a percentage of the native intact joint. Results: A statistically significant difference in the mean CP measured with the hip-specific device was observed before and after cam osteoplasty at 0° (41.2% (SD 29.7%); p = 0.014), 30° (54.5% (SD 16.6%); p = 0.011), 60° (39.8% (SD 23.0%); p < 0.001), 80° of flexion (36.3% (SD 22.1%); p < 0.001), and 80° of flexion with 20° of internal rotation (26.0% (SD 22.4%); p < 0.001). The ICP sensor is very fragile and difficult to handle in hip arthroscopy. Consequently, we limited the evaluations using this sensor to five hips. A statistically significant difference in the CP was found before and after cam osteoplasty at 80° of flexion (57.6% (SD 29.1%); p = 0.004). Conclusion: This biomechanical study evaluated a new hip-specific device to intraoperatively measure the CP in arthroscopic surgery. It showed a significant decrease in the CP after arthroscopic cam resection with the joint in different positions. At 80° of flexion with 20° of internal rotation, a typical position to detect hip impingement, the CP was reduced to 26% after arthroscopic cam resection. The intraoperative measurement of CP provides surgeons with feedback to evaluate the effectiveness of the osteoplasty. Cite this article: Bone Joint Res 2025;14(11):1053–1063.
- 21 November 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (11) , 1053-1063
Open AccessArthroscopic cam resection reduces femoroacetabular contact pressure
Aims: Arthroscopic cam resection in femoroacetabular impingement syndrome leads to clinical improvement, but biomechanical studies on the effect of surgical intervention are scarce. In this study, we compared the femoroacetabular contact pressure (CP) in an intact cam morphology and after arthroscopic cam resection. The hypothesis was that arthroscopic cam resection decreases the femoroacetabular CP. Methods: A cadaveric study was performed on nine hips with a cam morphology (α angle > 60°). CP was assessed using a new hip-specific device and an intracranial pressure (ICP) sensor. These evaluations were performed during hip arthroscopy, in the intact joint and after cam resection, with the joint in different positions. These measurements were normalized and reported as a percentage of the native intact joint. Results: A statistically significant difference in the mean CP measured with the hip-specific device was observed before and after cam osteoplasty at 0° (41.2% (SD 29.7%); p = 0.014), 30° (54.5% (SD 16.6%); p = 0.011), 60° (39.8% (SD 23.0%); p < 0.001), 80° of flexion (36.3% (SD 22.1%); p < 0.001), and 80° of flexion with 20° of internal rotation (26.0% (SD 22.4%); p < 0.001). The ICP sensor is very fragile and difficult to handle in hip arthroscopy. Consequently, we limited the evaluations using this sensor to five hips. A statistically significant difference in the CP was found before and after cam osteoplasty at 80° of flexion (57.6% (SD 29.1%); p = 0.004). Conclusion: This biomechanical study evaluated a new hip-specific device to intraoperatively measure the CP in arthroscopic surgery. It showed a significant decrease in the CP after arthroscopic cam resection with the joint in different positions. At 80° of flexion with 20° of internal rotation, a typical position to detect hip impingement, the CP was reduced to 26% after arthroscopic cam resection. The intraoperative measurement of CP provides surgeons with feedback to evaluate the effectiveness of the osteoplasty. Cite this article: Bone Joint Res 2025;14(11):1053–1063.
- Open Access
- 14 June 2024
- Published by Wiley in Arthroscopy Techniques
- Vol. 13 (9) , e1-e7
Femoroacetabular Contact Force Measurement in Hip Arthroscopy: Surgical Technique
The femoroacetabular contact force and pressure are increased in the anterosuperior segment of the acetabulum in femoroacetabular impingement syndrome. We developed a special device for femoroacetabular contact force measurement in hip arthroscopy and present the surgical technique for measuring femoroacetabular contact force in the intact joint with a cam morphology and after cam resection, with the hip in different positions in a cadaver specimen. The device is introduced into the joint peripheral compartment. After joint distraction, the sensor is deployed through the cannula and advanced into the central compartment under direct arthroscopic control. We show a decrease in the contact force measured with this device after cam resection. This force analysis is limited to the anterosuperior femoroacetabular junction, which is the most frequent location for labral and chondral pathology in cam‐type femoroacetabular impingement syndrome. We believe that this device also can be used in the evaluation of the contact forces in other joint conditions and in the assessment of diverse techniques of labral repair or reconstruction. Technique Video: video See video under supplementary data.
- 14 June 2024
- Published by Wiley in Arthroscopy Techniques
- Vol. 13 (9) , e1-e7
Open AccessFemoroacetabular Contact Force Measurement in Hip Arthroscopy: Surgical Technique
The femoroacetabular contact force and pressure are increased in the anterosuperior segment of the acetabulum in femoroacetabular impingement syndrome. We developed a special device for femoroacetabular contact force measurement in hip arthroscopy and present the surgical technique for measuring femoroacetabular contact force in the intact joint with a cam morphology and after cam resection, with the hip in different positions in a cadaver specimen. The device is introduced into the joint peripheral compartment. After joint distraction, the sensor is deployed through the cannula and advanced into the central compartment under direct arthroscopic control. We show a decrease in the contact force measured with this device after cam resection. This force analysis is limited to the anterosuperior femoroacetabular junction, which is the most frequent location for labral and chondral pathology in cam‐type femoroacetabular impingement syndrome. We believe that this device also can be used in the evaluation of the contact forces in other joint conditions and in the assessment of diverse techniques of labral repair or reconstruction. Technique Video: video See video under supplementary data.
- Open Access
- 4 December 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 12 (12) , 712-721
Hip joint contact pressure and force: a scoping review of in vivo and cadaver studies
Aims: Research on hip biomechanics has analyzed femoroacetabular contact pressures and forces in distinct hip conditions, with different procedures, and used diverse loading and testing conditions. The aim of this scoping review was to identify and summarize the available evidence in the literature for hip contact pressures and force in cadaver and in vivo studies, and how joint loading, labral status, and femoral and acetabular morphology can affect these biomechanical parameters.Methods: We used the PRISMA extension for scoping reviews for this literature search in three databases. After screening, 16 studies were included for the final analysis.Results: The studies assessed different hip conditions like labrum status, the biomechanical effect of the cam, femoral version, acetabular coverage, and the effect of rim trimming. The testing and loading conditions were also quite diverse, and this disparity limits direct comparisons between the different researches. With normal anatomy the mean contact pressures ranged from 1.54 to 4.4 MPa, and the average peak contact pressures ranged from 2 to 9.3 MPa. Labral tear or resection showed an increase in contact pressures that diminished after repair or reconstruction of the labrum. Complete cam resection also decreased the contact pressure, and acetabular rim resection of 6 mm increased the contact pressure at the acetabular base.Conclusion: To date there is no standardized methodology to access hip contact biomechanics in hip arthroscopy, or with the preservation of the periarticular soft-tissues. A tendency towards improved biomechanics (lower contact pressures) was seen with labral repair and reconstruction techniques as well as with cam correction.Cite this article: Bone Joint Res 2023;12(12):712–721.
- 4 December 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 12 (12) , 712-721
Open AccessHip joint contact pressure and force: a scoping review of in vivo and cadaver studies
Aims: Research on hip biomechanics has analyzed femoroacetabular contact pressures and forces in distinct hip conditions, with different procedures, and used diverse loading and testing conditions. The aim of this scoping review was to identify and summarize the available evidence in the literature for hip contact pressures and force in cadaver and in vivo studies, and how joint loading, labral status, and femoral and acetabular morphology can affect these biomechanical parameters.Methods: We used the PRISMA extension for scoping reviews for this literature search in three databases. After screening, 16 studies were included for the final analysis.Results: The studies assessed different hip conditions like labrum status, the biomechanical effect of the cam, femoral version, acetabular coverage, and the effect of rim trimming. The testing and loading conditions were also quite diverse, and this disparity limits direct comparisons between the different researches. With normal anatomy the mean contact pressures ranged from 1.54 to 4.4 MPa, and the average peak contact pressures ranged from 2 to 9.3 MPa. Labral tear or resection showed an increase in contact pressures that diminished after repair or reconstruction of the labrum. Complete cam resection also decreased the contact pressure, and acetabular rim resection of 6 mm increased the contact pressure at the acetabular base.Conclusion: To date there is no standardized methodology to access hip contact biomechanics in hip arthroscopy, or with the preservation of the periarticular soft-tissues. A tendency towards improved biomechanics (lower contact pressures) was seen with labral repair and reconstruction techniques as well as with cam correction.Cite this article: Bone Joint Res 2023;12(12):712–721.
- 2 January 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (5) , 1453-1460
Hip arthroscopy with initial access to the peripheral compartment provides significant improvement in FAI patients
Purpose: This study was designed to evaluate the clinical and radiographic results of arthroscopic treatment of femoroacetabular impingement (FAI) using the technique of initial access to the peripheral compartment. It is based on a single surgeon large case series with a minimum of 2 years follow‐up.Methods: Prospective longitudinal study with consecutive patients. Inclusion criteria were the presence of FAI syndrome that had failed non‐operative treatment and had a hip arthroscopy with initial access to the peripheral compartment. Exclusion criteria were previous hip surgery, patients younger than 16 or older than 60 years, Tönnis grade ≥ 2 osteoarthritis, hip dysplasia based on radiographic evidence of LCEA less than 25° and workers compensation cases. One hundred and sixty hips met the inclusion criteria, 84 were female and 70 were male patients (six bilateral cases), with a median age of 36 years (range 16–59).Results: The median alpha angle correction was 22.6º (range 5.9–46.7) (p < 0.01) and the average LCEA correction when acetabuloplasty was undertaken was 6.5º (range − 1.4–20.8) (p < 0.01). The mean NAHS at baseline was 56.1 (range 16–96) and improved to 83.2 at the last follow up (range 44–100) for the patients that had no additional procedure (p < 0.01). The mean average improvement was 27.7º points (range − 16–73). No iatrogenic labral perforation and no full‐thickness chondral damage were recorded during the arthroscopic procedures.Conclusions: Favourable outcomes are reported for the arthroscopic treatment of FAI with initial access to the peripheral compartment. The technique is protective against iatrogenic chondral and labral damage, more conservative to the joint capsule, but the mean traction time was relatively long when suture anchors were used. The results are comparable to the classic initial central compartment approach.Level of evidence: Level IV.
- 2 January 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (5) , 1453-1460
Hip arthroscopy with initial access to the peripheral compartment provides significant improvement in FAI patients
Purpose: This study was designed to evaluate the clinical and radiographic results of arthroscopic treatment of femoroacetabular impingement (FAI) using the technique of initial access to the peripheral compartment. It is based on a single surgeon large case series with a minimum of 2 years follow‐up.Methods: Prospective longitudinal study with consecutive patients. Inclusion criteria were the presence of FAI syndrome that had failed non‐operative treatment and had a hip arthroscopy with initial access to the peripheral compartment. Exclusion criteria were previous hip surgery, patients younger than 16 or older than 60 years, Tönnis grade ≥ 2 osteoarthritis, hip dysplasia based on radiographic evidence of LCEA less than 25° and workers compensation cases. One hundred and sixty hips met the inclusion criteria, 84 were female and 70 were male patients (six bilateral cases), with a median age of 36 years (range 16–59).Results: The median alpha angle correction was 22.6º (range 5.9–46.7) (p < 0.01) and the average LCEA correction when acetabuloplasty was undertaken was 6.5º (range − 1.4–20.8) (p < 0.01). The mean NAHS at baseline was 56.1 (range 16–96) and improved to 83.2 at the last follow up (range 44–100) for the patients that had no additional procedure (p < 0.01). The mean average improvement was 27.7º points (range − 16–73). No iatrogenic labral perforation and no full‐thickness chondral damage were recorded during the arthroscopic procedures.Conclusions: Favourable outcomes are reported for the arthroscopic treatment of FAI with initial access to the peripheral compartment. The technique is protective against iatrogenic chondral and labral damage, more conservative to the joint capsule, but the mean traction time was relatively long when suture anchors were used. The results are comparable to the classic initial central compartment approach.Level of evidence: Level IV.
- 26 August 2020
- Published by Springer Nature in Current Reviews in Musculoskeletal Medicine
- Vol. 13 (5) , 622-640
Advances in FAI Imaging: a Focused Review
Purpose of Review Femoroacetabular impingement (FAI) is one of the main causes of hip pain in young adults and poses clinical challenges which have placed it at the forefront of imaging and orthopedics. Diagnostic hip imaging has dramatically changed in the past years, with the arrival of new imaging techniques and the development of magnetic resonance imaging (MRI). This article reviews the current state-of-the-art clinical routine of individuals with suspected FAI, limitations, and future directions that show promise in the field of musculoskeletal research and are likely to reshape hip imaging in the coming years. Recent Findings The largely unknown natural disease course, especially in hips with FAI syndrome and those with asymptomatic abnormal morphologies, continues to be a problem as far as diagnosis, treatment, and prognosis are concerned. There has been a paradigm shift in recent years from bone and soft tissue morphological analysis towards the tentative development of quantitative approaches, biochemical cartilage evaluation, dynamic assessment techniques and, finally, integration of artificial intelligence (AI)/deep learning systems. Summary Imaging, AI, and hip preserving care will continue to evolve with new problems and greater challenges. The increasing number of analytic parameters describing the hip joint, as well as new sophisticated MRI and imaging analysis, have carried practitioners beyond simplistic classifications. Reliable evidence-based guidelines, beyond differentiation into pure instability or impingement, are paramount to refine the diagnostic algorithm and define treatment indications and prognosis. Nevertheless, the boundaries of morphological, functional, and AI-aided hip assessment are gradually being pushed to new frontiers as the role of musculoskeletal imaging is rapidly evolving.
- 26 August 2020
- Published by Springer Nature in Current Reviews in Musculoskeletal Medicine
- Vol. 13 (5) , 622-640
Advances in FAI Imaging: a Focused Review
Purpose of Review Femoroacetabular impingement (FAI) is one of the main causes of hip pain in young adults and poses clinical challenges which have placed it at the forefront of imaging and orthopedics. Diagnostic hip imaging has dramatically changed in the past years, with the arrival of new imaging techniques and the development of magnetic resonance imaging (MRI). This article reviews the current state-of-the-art clinical routine of individuals with suspected FAI, limitations, and future directions that show promise in the field of musculoskeletal research and are likely to reshape hip imaging in the coming years. Recent Findings The largely unknown natural disease course, especially in hips with FAI syndrome and those with asymptomatic abnormal morphologies, continues to be a problem as far as diagnosis, treatment, and prognosis are concerned. There has been a paradigm shift in recent years from bone and soft tissue morphological analysis towards the tentative development of quantitative approaches, biochemical cartilage evaluation, dynamic assessment techniques and, finally, integration of artificial intelligence (AI)/deep learning systems. Summary Imaging, AI, and hip preserving care will continue to evolve with new problems and greater challenges. The increasing number of analytic parameters describing the hip joint, as well as new sophisticated MRI and imaging analysis, have carried practitioners beyond simplistic classifications. Reliable evidence-based guidelines, beyond differentiation into pure instability or impingement, are paramount to refine the diagnostic algorithm and define treatment indications and prognosis. Nevertheless, the boundaries of morphological, functional, and AI-aided hip assessment are gradually being pushed to new frontiers as the role of musculoskeletal imaging is rapidly evolving.
- 29 May 2020
- Published by Springer Nature
- p. 219-223
Endoscopic Trochanteric Bursectomy
- 14 May 2020
- Published by Springer Nature in European Radiology
- Vol. 30 (10) , 5281-5297
The Lisbon Agreement on Femoroacetabular Impingement Imaging—part 1: overview
Objectives Imaging assessment for the clinical management of femoroacetabular impingement (FAI) syndrome remains controversial because of a paucity of evidence-based guidance and notable variability in clinical practice, ultimately requiring expert consensus. The purpose of this agreement is to establish expert-based statements on FAI imaging, using formal techniques of consensus building. Methods A validated Delphi method and peer-reviewed literature were used to formally derive consensus among 30 panel members (21 musculoskeletal radiologists and 9 orthopaedic surgeons) from 13 countries. Forty-four questions were agreed on, and recent relevant seminal literature was circulated and classified in five major topics (‘General issues’, ‘Parameters and reporting’, ‘Radiographic assessment’, ‘MRI’ and ‘Ultrasound’) in order to produce answering statements. The level of evidence was noted for all statements, and panel members were asked to score their level of agreement with each statement (0 to 10) during iterative rounds. Either ‘consensus’, ‘agreement’ or ‘no agreement’ was achieved. Results Forty-seven statements were generated, and group consensus was reached for 45 (95.7%). Seventeen of these statements were selected as most important for dissemination in advance. There was no agreement for the two statements pertaining to ‘Ultrasound’. Conclusion Radiographic evaluation is the cornerstone of hip evaluation. An anteroposterior pelvis radiograph and a Dunn 45° view are recommended for the initial assessment of FAI although MRI with a dedicated protocol is the gold standard imaging technique in this setting. The resulting consensus can serve as a tool to reduce variability in clinical practices and guide further research for the clinical management of FAI. Key Points • FAI imaging literature is extensive although often of low level of evidence. • Radiographic evaluation with a reproducible technique is the cornerstone of hip imaging assessment. • MRI with a dedicated protocol is the gold standard imaging technique for FAI assessment.
- 14 May 2020
- Published by Springer Nature in European Radiology
- Vol. 30 (10) , 5281-5297
The Lisbon Agreement on Femoroacetabular Impingement Imaging—part 1: overview
Objectives Imaging assessment for the clinical management of femoroacetabular impingement (FAI) syndrome remains controversial because of a paucity of evidence-based guidance and notable variability in clinical practice, ultimately requiring expert consensus. The purpose of this agreement is to establish expert-based statements on FAI imaging, using formal techniques of consensus building. Methods A validated Delphi method and peer-reviewed literature were used to formally derive consensus among 30 panel members (21 musculoskeletal radiologists and 9 orthopaedic surgeons) from 13 countries. Forty-four questions were agreed on, and recent relevant seminal literature was circulated and classified in five major topics (‘General issues’, ‘Parameters and reporting’, ‘Radiographic assessment’, ‘MRI’ and ‘Ultrasound’) in order to produce answering statements. The level of evidence was noted for all statements, and panel members were asked to score their level of agreement with each statement (0 to 10) during iterative rounds. Either ‘consensus’, ‘agreement’ or ‘no agreement’ was achieved. Results Forty-seven statements were generated, and group consensus was reached for 45 (95.7%). Seventeen of these statements were selected as most important for dissemination in advance. There was no agreement for the two statements pertaining to ‘Ultrasound’. Conclusion Radiographic evaluation is the cornerstone of hip evaluation. An anteroposterior pelvis radiograph and a Dunn 45° view are recommended for the initial assessment of FAI although MRI with a dedicated protocol is the gold standard imaging technique in this setting. The resulting consensus can serve as a tool to reduce variability in clinical practices and guide further research for the clinical management of FAI. Key Points • FAI imaging literature is extensive although often of low level of evidence. • Radiographic evaluation with a reproducible technique is the cornerstone of hip imaging assessment. • MRI with a dedicated protocol is the gold standard imaging technique for FAI assessment.