In vitro and in vivo studies of osteoblast cell response to a titanium-6 aluminium-4 vanadium surface modified by neodymium:yttrium–aluminium–garnet laser and silicon carbide paper
- 19 November 2008
- journal article
- Published by Springer Nature in Lasers in Medical Science
- Vol. 24 (6) , 925-939
Abstract
The effects of neodymium:yttrium–aluminium–garnet (Nd:YAG) laser and silicon carbide (SiC) paper on the surface micro-topography of titanium-6 aluminium-4 vanadium (Ti6Al4V) alloy were examined in relation to the response of bone cells. The study was performed in three distinct stages: (1) after surface treatment of samples by laser and SiC paper, the surface hardness, surface roughness, corrosion resistance and surface tension were evaluated; (2) the growth of mouse connective tissue fibroblast cells (L-929) on untreated and treated samples was assessed in vitro; (3) the response of goat osteoblast cells to untreated and treated implanted samples was assessed in vivo. The surface roughness varied between 7 ± 0.02 for laser-treated samples (LTSs) at 140 J cm−2 and 21.8 ± 0.05 for mechanically treated samples (MTSs). The surface hardness was found to vary from 377 Vickers hardness number (VHN) for MTSs to 850 VHN for LTSs. A corrosion potential of −0.21V was achieved for the LTSs compared with −0.51V for the MTSs. The LTSs exhibited a more hydrophilic behaviour (i.e. wettability) than did the MTSs. No cytotoxicity effect, unlike for the MTSs, was observed for the LTSs. The results of in vivo tests indicated longitudinal growth of osteoblast cells along the grooves on the samples formed by the SiC paper, and multidirectional spreading of the cells on the LTSs.Keywords
This publication has 31 references indexed in Scilit:
- Effects of Nd:Yag laser irradiation on osteoblast cell culturesLasers in Medical Science, 2006
- Laser-assisted three-dimensional surface modifications of titanium implants: preliminary dataLasers in Medical Science, 2005
- Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome techniqueClinical Oral Implants Research, 2004
- Influence of the in vitro culture period on the in vivo performance of cell/titanium bone tissue‐engineered constructs using a rat cranial critical size defect modelJournal of Biomedical Materials Research Part A, 2003
- A study on the effect of dual blasting with TiO2 on titanium implant surfaces on functional attachment in boneJournal of Biomedical Materials Research Part A, 2003
- Quantitative analysis of osteoblast behavior on microgrooved hydroxyapatite and titanium substrataJournal of Biomedical Materials Research Part A, 2003
- Osteoinduction, osteoconduction and osseointegrationEuropean Spine Journal, 2001
- In vitro and in vivo biocompatibility testing of Ti‐6Al‐7Nb alloy with and without plasma‐sprayed hydroxyapatite coatingJournal of Biomedical Materials Research, 2001
- Computer‐Assisted three‐dimensional reconstruction of epithelial cells attached to percutaneous implantsJournal of Biomedical Materials Research, 1995
- Effects of substratum morphology on cell physiologyBiotechnology and Bioengineering, 1994