Mahboobeh Mahmoodi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Mahboobeh Mahmoodi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Etrati Khosroshahi
Amirkabir University of Technology
2 shared publications - Fatemeh Atyabi
Department of pharmaceutical nanotechnology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
1 shared publication H. Saeedinasab
Yazd School of Medicine
1 shared publication
Latest Publications
- 17 February 2011
- Published by Wiley in Journal of Biophotonics
- Vol. 4 (6) , 403-414
Dynamic study of PLGA/CS nanoparticles delivery containing drug model into phantom tissue using CO2 laser for clinical applications
In this study, cationic nanoparticles (NPs) were prepared by coating chitosan (CS) on the surface of PLGA NPs. To our knowledge most of the work in the field of drug delivery systems using lasers has been performed using short pulses with micron and submicron durations. We carried out an experiment using superlong PLS‐R (10 ms) and CW CO2laser modes on simulated drug‐biogelatin model where drug was encapsulated by PLGA/CS NPs. Maximum depth of drug containing cavitation was achieved faster at higher powers and shorter irradiation time in CWC mode. We believe that the main mechanism at work with superlong pulses is both photothermal due to vaporization and photomechanical due to photophoresis and cavitation collapse. In the case of CW, however, it is purely photothermal. Thus, drug molecules can be transported into tissue bulk by thermal waves which can be described by the Fick's law in 3‐D model for a given cavity geometry and the mechanical waves, unlike only by pure photomechanical waves (i.e. photoacoustically) as with short pulses. Therefore, our studies could offer an alternative for currently existing method for drug delivery.
- 17 February 2011
- Published by Wiley in Journal of Biophotonics
- Vol. 4 (6) , 403-414
Dynamic study of PLGA/CS nanoparticles delivery containing drug model into phantom tissue using CO2 laser for clinical applications
In this study, cationic nanoparticles (NPs) were prepared by coating chitosan (CS) on the surface of PLGA NPs. To our knowledge most of the work in the field of drug delivery systems using lasers has been performed using short pulses with micron and submicron durations. We carried out an experiment using superlong PLS‐R (10 ms) and CW CO2laser modes on simulated drug‐biogelatin model where drug was encapsulated by PLGA/CS NPs. Maximum depth of drug containing cavitation was achieved faster at higher powers and shorter irradiation time in CWC mode. We believe that the main mechanism at work with superlong pulses is both photothermal due to vaporization and photomechanical due to photophoresis and cavitation collapse. In the case of CW, however, it is purely photothermal. Thus, drug molecules can be transported into tissue bulk by thermal waves which can be described by the Fick's law in 3‐D model for a given cavity geometry and the mechanical waves, unlike only by pure photomechanical waves (i.e. photoacoustically) as with short pulses. Therefore, our studies could offer an alternative for currently existing method for drug delivery.
- 19 November 2008
- Published by Springer Nature in Lasers in Medical Science
- Vol. 24 (6) , 925-939
In vitro and in vivo studies of osteoblast cell response to a titanium-6 aluminium-4 vanadium surface modified by neodymium:yttrium–aluminium–garnet laser and silicon carbide paper
The effects of neodymium:yttrium–aluminium–garnet (Nd:YAG) laser and silicon carbide (SiC) paper on the surface micro-topography of titanium-6 aluminium-4 vanadium (Ti6Al4V) alloy were examined in relation to the response of bone cells. The study was performed in three distinct stages: (1) after surface treatment of samples by laser and SiC paper, the surface hardness, surface roughness, corrosion resistance and surface tension were evaluated; (2) the growth of mouse connective tissue fibroblast cells (L-929) on untreated and treated samples was assessed in vitro; (3) the response of goat osteoblast cells to untreated and treated implanted samples was assessed in vivo. The surface roughness varied between 7 ± 0.02 for laser-treated samples (LTSs) at 140 J cm−2 and 21.8 ± 0.05 for mechanically treated samples (MTSs). The surface hardness was found to vary from 377 Vickers hardness number (VHN) for MTSs to 850 VHN for LTSs. A corrosion potential of −0.21V was achieved for the LTSs compared with −0.51V for the MTSs. The LTSs exhibited a more hydrophilic behaviour (i.e. wettability) than did the MTSs. No cytotoxicity effect, unlike for the MTSs, was observed for the LTSs. The results of in vivo tests indicated longitudinal growth of osteoblast cells along the grooves on the samples formed by the SiC paper, and multidirectional spreading of the cells on the LTSs.
- 19 November 2008
- Published by Springer Nature in Lasers in Medical Science
- Vol. 24 (6) , 925-939
In vitro and in vivo studies of osteoblast cell response to a titanium-6 aluminium-4 vanadium surface modified by neodymium:yttrium–aluminium–garnet laser and silicon carbide paper
The effects of neodymium:yttrium–aluminium–garnet (Nd:YAG) laser and silicon carbide (SiC) paper on the surface micro-topography of titanium-6 aluminium-4 vanadium (Ti6Al4V) alloy were examined in relation to the response of bone cells. The study was performed in three distinct stages: (1) after surface treatment of samples by laser and SiC paper, the surface hardness, surface roughness, corrosion resistance and surface tension were evaluated; (2) the growth of mouse connective tissue fibroblast cells (L-929) on untreated and treated samples was assessed in vitro; (3) the response of goat osteoblast cells to untreated and treated implanted samples was assessed in vivo. The surface roughness varied between 7 ± 0.02 for laser-treated samples (LTSs) at 140 J cm−2 and 21.8 ± 0.05 for mechanically treated samples (MTSs). The surface hardness was found to vary from 377 Vickers hardness number (VHN) for MTSs to 850 VHN for LTSs. A corrosion potential of −0.21V was achieved for the LTSs compared with −0.51V for the MTSs. The LTSs exhibited a more hydrophilic behaviour (i.e. wettability) than did the MTSs. No cytotoxicity effect, unlike for the MTSs, was observed for the LTSs. The results of in vivo tests indicated longitudinal growth of osteoblast cells along the grooves on the samples formed by the SiC paper, and multidirectional spreading of the cells on the LTSs.