Low-Frequency Coherent Raman Imaging Robust to Optical Scattering
Open Access
- 8 July 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Chemical & Biomedical Imaging
- Vol. 2 (8) , 584-591
Abstract
We demonstrate low-frequency interferometric impulsive stimulated Raman scattering (ISRS) imaging with high robustness to distortions by optical scattering. ISRS is a pump-probe coherent Raman spectroscopy that can capture Raman vibrational spectra. Recording of ISRS spectra requires isolation of a probe pulse from the pump pulse. While this separation is simple in nonscattering specimens, such as liquids, scattering leads to significant pump pulse contamination and prevents the extraction of a Raman spectrum. We introduce a robust method for ISRS microscopy that works in complex scattering samples. High signal-to-noise ISRS spectra are obtained even when the pump and probe pulses pass through many scattering layers.Keywords
All Related Versions
Funding Information
- Agence Nationale de la Recherche (ANR-21-ESRS-0002 IDEC)
- U.S. Department of Energy (DE-SC0002613, DE-SC0019545)
- HORIZON EUROPE European Innovation Council (101099058)
- European Commission (101016923)
- U.S. Department of Health and Human Services (5 R21GM135772-02)
- European Commission (101052911)
This publication has 36 references indexed in Scilit:
- Broadband Optical Activity Spectroscopy with Interferometric Fourier-Transform Balanced DetectionACS Photonics, 2021
- Low-Frequency Raman Spectroscopy of Few-Layer 2H-SnS2Scientific Reports, 2018
- Characterising live cell behaviour: Traditional label-free and quantitative phase imaging approachesThe International Journal of Biochemistry & Cell Biology, 2017
- Low-Frequency Raman Fingerprints of Two-Dimensional Metal Dichalcogenide Layer Stacking ConfigurationsACS Nano, 2015
- A novel combination of DLS-optical microrheology and low frequency Raman spectroscopy to reveal underlying biopolymer self-assembly and gelation mechanismsThe Journal of Chemical Physics, 2014
- Label‐Free Analysis of Cellular Biochemistry by Raman Spectroscopy and Microscopy2013
- Label-free imaging through nonlinear optical signalsMaterials Today, 2011
- Synthetic temporal aperture coherent molecular phase spectroscopyChemical Physics Letters, 2008
- Generating coherent THz phonons with light pulsesSolid State Communications, 1997
- Time-resolved vibrational spectroscopy in the impulsive limitChemical Reviews, 1994