JWJesse W. Wilson

Jesse W. Wilson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jesse W. Wilson has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reflectance-guided denoising of second harmonic generation microscopy

    by Jesse W. Wilson, Arya C. Mugdha

    Multiphoton microscopy produces label-free, molecule-specific images of biological tissues, but relies on weak nonlinear interactions to generate signal. This means, even with sensitive detectors and high-intensity pulse laser sources, the signal-to-noise ratio, and hence, speed, are limited. Deep learning virtual staining may some day make it possible to replace multiphoton acquisition with simpler, faster modalities like reflectance confocal microscopy, but the lack of molecular specificity seriously limits the accuracy of such an approach. Here we demonstrate proof of concept of a hybrid approach, using reflectance images not to synthesis multiphoton images de novo, but to assist restoration of noisy multiphoton images.

  • Galvanometer-scanning transient phase microscopy with balanced detection and arbitrary pump polarization

    by Cameron N. Coleal, Randy A. Bartels, Jesse W. Wilson

    Transient absorption microscopy measures excited-state kinetics based on the imaginary part of the pump-induced perturbation to the complex refractive index, i.e., ℑ{Δ N }, with applications in both materials and biomedical sciences. Its complement, transient phase microscopy, enabled by stable inline birefringent interferometry, measures the real part ℜ{Δ N }. The ability to switch between absorption and phase measurements may yield a stronger signal, depending on the sample and probe wavelength. To date, however, transient phase has not been coupled with galvanometer scanners, thus limiting it to materials science applications and non-imaging spectroscopy. Here, we extend transient phase microscopy to operate in a galvanometer-scanning microscope with balanced detection, comparing amplitude and phase measurements in graphene (in which amplitude detection has the advantage), hemoglobin, and red blood cells (in which phase detection has the advantage). We examine the impacts and limitations introduced by galvanometer scanning, in addition to the relocation of the pump–probe combining dichroic to permit arbitrary polarization of the pump.

  • Image class translation: visual inspection of class-specific hypotheticals and classification based on translation distance

    by Mikyla K. Bowen, Jesse W. Wilson

    PurposeA major barrier to the implementation of artificial intelligence for medical applications is automated CNNs’ lack of explainability and high confidence for incorrect decisions, specifically with out-of-domain samples. We propose a generalization of image translation networks for image classification and demonstrate translation networks’ potential as a more interpretable alternative to conventional black-box classifiers.ApproachWe train an image-to-image network to translate an input image to class-specific hypotheticals, and then compare these with the input, both visually and quantitatively. Translation distances, the degree of alteration needed to conform to one class or another, are examined for clusters and trends, and used as a simple low-dimensional feature vector for classification.ResultsOn melanoma/benign dermoscopy images, a translation distance classifier achieved 80% accuracy using only a two-dimensional feature space (versus 85% for a conventional CNN using a ∼62,000-dimensional feature space). Visual inspection of rendered images revealed dataset biases, such as more scale bars in melanoma photographs than in benign lesions. Image distributions in translation distance space revealed a natural separation along the lines of dermatologist decision to biopsy, rather than between malignant and benign. On bone marrow cytology images, translation distance classifiers outperformed a conventional CNN in both 3-class (92% accuracy versus 89% for CNN) and 6-class (90% versus 86% for CNN) scenarios.ConclusionsThis proof-of-concept shows the potential for image-to-image translation to go beyond artistic/stylistic changes and to expose dataset biases, perform dimension reduction and dataset visualization, and in some cases, potentially outperform conventional end-to-end CNN classifiers.

  • Open Access

    Low-Frequency Coherent Raman Imaging Robust to Optical Scattering

    by David R. Smith, Jesse W. Wilson, Siddarth Shivkumar, Hervé Rigneault, Randy A. Bartels

    We demonstrate low-frequency interferometric impulsive stimulated Raman scattering (ISRS) imaging with high robustness to distortions by optical scattering. ISRS is a pump-probe coherent Raman spectroscopy that can capture Raman vibrational spectra. Recording of ISRS spectra requires isolation of a probe pulse from the pump pulse. While this separation is simple in nonscattering specimens, such as liquids, scattering leads to significant pump pulse contamination and prevents the extraction of a Raman spectrum. We introduce a robust method for ISRS microscopy that works in complex scattering samples. High signal-to-noise ISRS spectra are obtained even when the pump and probe pulses pass through many scattering layers.


  • Ultrafast pulse retrieval with one-shot unsupervised deep learning

    by Jesse W. Wilson

    Recently, much attention has been drawn to deep learning models, namely deep Convolutional Neural Networks (CNNs) trained in a supervised fashion. Supervised learning is time consuming, requires a large dataset where the answer is already known, and often fails to generalize to new cases with patterns or noise statistics that were not foreseen in the training data. Unsupervised learning, on the other hand, does not use prior knowledge of the answer, can adapt to new data at hand, and can learn from single examples. A CNN can solve inverse problems in this way by learning to produce a result that, when passed through a forward model, recovers the experimental measurement. For example, a CNN can be trained in a supervised fashion to recover the complex field of a pulse from its Frequency-Resolved Optical Gating (FROG) measurement, by training it on thousands of examples of FROG measurements (the network inputs) and their corresponding optical pulses (the target outputs). In unsupervised learning, the network learns to transform a FROG measurement into an optical pulse, that, when passed through a forward model, recovers the original FROG measurement. We find this succeeds even on single FROG measurements, opening up new possibilities for analyzing measurements that fall outside the foreseeable distribution of training data.

  • Sparse Lissajous scanning reflectance confocal microscope with an adjustable field of view and fast iterative Fourier filtering reconstruction

    by Cameron N. Coleal, William A. Hudson, Jesse W. Wilson

    Medical imaging devices are becoming increasingly compact, necessitating optimization research into different methods of actuation. Actuation influences important parameters of the imaging device such as size, weight, frame rate, field of view (FOV), and image reconstruction for imaging devices point scanning techniques. Current literature around piezoelectric fiber cantilever actuators focuses on device optimization with a fixed FOV but neglects adjustability. In this paper, we introduce an adjustable FOV piezoelectric fiber cantilever microscope and provide a characterization and optimization procedure. To overcome calibration challenges, we utilize a position sensitive detector (PSD) and address trade-offs between FOV and sparsity with a novel inpainting technique. Our work demonstrates the potential for scanner operation when sparsity and distortion dominate the FOV, extending the usable FOV for this form of actuation and others that currently only operate under ideal imaging conditions.


  • Nearly degenerate two-color impulsive coherent Raman hyperspectral imaging

    by David R. Smith, Siddarth Shivkumar, Jeffrey Field, Jesse W. Wilson, Hervé Rigneault, Randy A. Bartels

    Impulsive stimulated Raman scattering (ISRS) is a robust technique for studying low frequency (−1) Raman vibrational modes, but ISRS has faced difficulty in translation to an imaging modality. A primary challenge is the separation of the pump and probe pulses. Here we introduce and demonstrate a simple strategy for ISRS spectroscopy and hyperspectral imaging that uses complementary steep edge spectral filters to separate the probe beam detection from the pump and enables simple ISRS microscopy with a single-color ultrafast laser source. ISRS spectra are obtained that span from the fingerprint region down to −1 vibrational modes. Hyperspectral imaging and polarization-dependent Raman spectra are also demonstrated.


  • Transient absorption spectroscopy and imaging of redox in muscle mitochondria

    by Erkang Wang, Luke A. Whitcomb, Adam J. Chicco, Jesse W. Wilson

    Mitochondrial redox is an important indicator of cell metabolism and health, with implications in cancer, diabetes, aging, neurodegenerative diseases, and mitochondrial disease. The most common method to observe redox of individual cells and mitochondria is through fluorescence of NADH and FAD+, endogenous cofactors serve as electron transport inputs to the mitochondrial respiratory chain. Yet this leaves out redox within the respiratory chain itself. To a degree, the missing information can be filled in by exogenous fluorophores, but at the risk of disturbed mitochondrial permeability and respiration. Here we show that variations in respiratory chain redox can be detected up by visible-wavelength transient absorption microscopy (TAM). In TAM, the selection of pump and probe wavelengths can provide multiphoton imaging contrast between non-fluorescent molecules. Here, we applied TAM with a pump at 520nm and probe at 450nm, 490nm, and 620nm to elicit redox contrast from mitochondrial respiratory chain hemeproteins. Experiments were performed with reduced and oxidized preparations of isolated mitochondria and whole muscle fibers, using mitochondrial fuels (malate, pyruvate, and succinate) to set up physiologically relevant oxidation levels. TAM images of muscle fibers were analyzed with multivariate curve resolution (MCR), revealing that the response at 620nm probe provides the best redox contrast and the most consistent response between whole cells and isolated mitochondria.


  • High-Repetition-Rate Transient Absorption Spectroscopy of Respiratory Supercomplexes

    by Erkang Wang, Kalyn S. Specht, Adam J. Chicco, Jesse W. Wilson

    Hemeproteins are frequent subjects for ultrafast transient absorption spectroscopy (TAS) because of biological importance, strong UV–vis absorption, high photostability, and interesting transient dynamics that depend on redox, conformation, and ligand binding. TAS on hemeproteins is usually performed on isolated, purified proteins, though their response is likely to be different in their native molecular environment, which involves the formation of protein complexes and supercomplexes. Recently, we reported a transient absorption microscopy (TAM) experiment which elicited a transient response from hemeproteins in intact biological tissue using a visible-wavelength pump (530 nm) and probe (490 nm). Here, we find that adaptive noise canceling plus resonant galvanometer scanning enables a high-repetition-rate fiber laser source to make redox-sensitive measurements of cytochrome c (Cyt-c). We investigate the origins of the visible-wavelength response of biological tissue through TAS of intact mitochondrial respiratory supercomplexes, separated via gel electrophoresis. We find that each of these high-molecular-weight gel bands yields a TAS response characteristic of cytochrome hemes, implying that the TAS response of intact cells and tissue originates from not just Cyt-c but a mixture of respiratory cytochromes. We also find differences in excited-state lifetime between wild-type (WT) and a tafazzin-deficient (TAZ) mouse model of mitochondrial disease.


  • Open Access

    Phase noise limited frequency shift impulsive Raman spectroscopy

    by David R. Smith, Jeffrey J. Field, David G. Winters, Scott R. Domingue, Frauke Rininsland, Daniel J. Kane, Jesse W. Wilson, Randy A. Bartels

    We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.