Equivalence of Influence of Pollution Simulating Methods on DC Flashover Stress of Ice-Covered Insulators
Authors:
- 11 December 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 25 (4) , 2113-2120
Abstract
The solid-layer method (SLM) and the icing-water- conductivity method (IWCM) are widely used in the insulator icing tests, but little research has been dedicated to the equivalence of these two methods. Based on the research on dc flashover performance of ice-covered insulators in the artificial climate chamber, this paper studied the equivalent relation between SLM and IWCM according to the equivalent principle of the flashover stress of ice-covered insulators. The results show that the influence of these two methods on flashover stress of iced insulator is equivalent, and this equivalence is determined by the configuration of insulator as well as the icing degree, but the icing flashover stress of the same type of insulators which are on the same pollution level simulated by the two different methods is consistent.Keywords
This publication has 12 references indexed in Scilit:
- DC flashover performance and effect of sheds configuration on polluted and ice–covered composite insulators at low atmospheric pressureIEEE Transactions on Dielectrics and Electrical Insulation, 2011
- Flashover Performance of Pre-contaminated and Ice-covered Composite Insulators to be Used in 1000 kV UHV AC Transmission LinesIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- Insulator Icing Test Methods, Selection Criteria and Mitigation AlternativesIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- Study on AC Flashover Performance and Discharge Process of Polluted and Iced IEC Standard Suspension Insulator StringIEEE Transactions on Power Delivery, 2006
- Effect of insulator diameter on AC flashover voltage of an ice-covered insulator stringIEEE Transactions on Dielectrics and Electrical Insulation, 2006
- Insulator icing test methods and procedures a position paper prepared by the ieee task force on insulator icing test methodsIEEE Transactions on Power Delivery, 2003
- The cold-fog test [for outdoor insulators]IEEE Transactions on Power Delivery, 1996
- AC flashover performance of insulators covered with artificial iceIEEE Transactions on Power Delivery, 1995
- Flashover problems caused by ice build up on insulatorsIEEE Electrical Insulation Magazine, 1995
- Accurate measurement of low insulator contamination levelsIEEE Transactions on Power Delivery, 1994