Reduction of Coronary Motion Artifacts in Prospectively Electrocardiography-Gated Coronary Computed Tomography Angiography Using Monochromatic Imaging at Various Energy Levels in Combination With a Motion Correction Algorithm on Single-Source Fast Tube Voltage Switching Dual-Energy Computed Tomography
- 1 August 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 51 (8) , 513-519
Abstract
Objectives: The aim of this study was to assess the effect of monochromatic imaging at various energy levels in combination with a motion correction algorithm (MCA) in single-source dual-energy coronary computed tomography angiography (CCTA) with fast switching of tube voltage on the reduction of coronary motion artifacts (CMA) in a phantom setting. Materials and Methods: Using this dual-energy computed tomography technique with a phantom comprising models of coronary vessels filled with contrast medium and pulsating at constant heart rates of 60 to 100 beats per minute, we reconstructed monochromatic images of CCTA obtained at 50 to 90 keV with and without use of MCA. Cardiac motion was modeled by simulating the in vivo time-volume curve of the left ventricle. Two independent readers graded CMA in 9 coronary segments using a 5-point scale (1, poor; 3 to 5, interpretable; 5, excellent). At each heart rate, we compared the average score of CMA between images obtained at 50 to 90 keV with and without use of MCA using Wilcoxon signed rank test, and we compared the score among images obtained at 50 to 90 keV with use of MCA using Kruskal-Wallis and post hoc tests. We also compared the percentages of image interpretability and improvement in image interpretability among images obtained at 50 to 90 keV with use of MCA. Results: With the use of MCA, the average score of CMA was significantly higher for images obtained at each energy level from 50 to 70 keV (P < 0.05) and was comparable at 80 and 90 keV, and it was comparable among those obtained at 50 to 70 keV. With its use, the percentages of image interpretability were similarly high at 50 to 70 keV at 60 to 80 beats per minute (78%–100%), and they were higher at 50 to 60 keV (72%–83%) than at 70 keV at 90 to 100 beats per minute (50%–56%). The percentages of improved image interpretability with MCA were similarly high at 50 to 70 keV at 60 to 80 beats per minute (56%–100%), and they were higher at 50 to 60 keV (62%–77%) than at 70 keV at 90 to 100 beats per minute (36%–43%). The percentages of image interpretability and improved image interpretability with MCA were insufficient at 80 and 90 keV. Conclusions: Coronary motion artifacts were significantly reduced in images of monochromatic CCTA obtained at 50 to 70 keV in combination with MCA compared with those obtained without MCA, and the percentages of image interpretability and improved image interpretability with use of MCA were relatively high at 50 to 70 keV, and particularly at 50 to 60 keV, even at 90 to 100 beats per minute.Keywords
This publication has 39 references indexed in Scilit:
- Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rateJapanese Journal of Radiology, 2014
- Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analysesEuropean Journal of Radiology, 2014
- Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correctionThe International Journal of Cardiovascular Imaging, 2014
- Impact of a New Motion-Correction Algorithm on Image Quality of Low-Dose Coronary CT Angiography in Patients with Insufficient Heart Rate ControlAcademic Radiology, 2014
- Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medicationsJournal of Cardiovascular Computed Tomography, 2012
- Diagnostic Performance of Coronary Angiography by 64-Row CTNew England Journal of Medicine, 2008
- Noninvasive Coronary Angiography with 64-Section CT: Effect of Average Heart Rate and Heart Rate Variability on Image QualityRadiology, 2006
- Assessment of Coronary Artery Disease by Cardiac Computed TomographyCirculation, 2006
- Multi–Detector Row CT Coronary Angiography: Influence of Reconstruction Technique and Heart Rate on Image QualityRadiology, 2006
- Noninvasive Coronary Angiography with 16–Detector Row CT: Effect of Heart RateRadiology, 2005