Haruhiko Machida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haruhiko Machida has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Eiko Ueno
From the *Department of Radiology, Tokyo Women's Medical University Medical Center East, Tokyo, Japan; †Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China; and ‡Department of Diagnostic Radiology, Saitama Red Cross Hospital, Saitama, Japan
18 shared publicationsYun Shen
From the *Department of Radiology, Tokyo Women's Medical University Medical Center East, Tokyo, Japan; †Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China; and ‡Department of Diagnostic Radiology, Saitama Red Cross Hospital, Saitama, Japan
8 shared publications- John Michael Sabol
GE Healthcare (United States)
7 shared publications Shigeru Suzuki
From the *Department of Radiology, Tokyo Women's Medical University Medical Center East, Tokyo, Japan; †Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China; and ‡Department of Diagnostic Radiology, Saitama Red Cross Hospital, Saitama, Japan
6 shared publicationsToshiyuki Yuhara
From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan (H.M., T.Y., M.T., T.I., E.T., E.U.); and GE Healthcare, Waukesha, Wis (K.N., J.M.S.).
6 shared publicationsRika Fukui
From the Department of Radiology, Tokyo Women's Medical University, Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo 116-8567, Japan
5 shared publications
Latest Publications
- 1 August 2016
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 51 (8) , 513-519
Reduction of Coronary Motion Artifacts in Prospectively Electrocardiography-Gated Coronary Computed Tomography Angiography Using Monochromatic Imaging at Various Energy Levels in Combination With a Motion Correction Algorithm on Single-Source Fast Tube Voltage Switching Dual-Energy Computed Tomography
Objectives: The aim of this study was to assess the effect of monochromatic imaging at various energy levels in combination with a motion correction algorithm (MCA) in single-source dual-energy coronary computed tomography angiography (CCTA) with fast switching of tube voltage on the reduction of coronary motion artifacts (CMA) in a phantom setting. Materials and Methods: Using this dual-energy computed tomography technique with a phantom comprising models of coronary vessels filled with contrast medium and pulsating at constant heart rates of 60 to 100 beats per minute, we reconstructed monochromatic images of CCTA obtained at 50 to 90 keV with and without use of MCA. Cardiac motion was modeled by simulating the in vivo time-volume curve of the left ventricle. Two independent readers graded CMA in 9 coronary segments using a 5-point scale (1, poor; 3 to 5, interpretable; 5, excellent). At each heart rate, we compared the average score of CMA between images obtained at 50 to 90 keV with and without use of MCA using Wilcoxon signed rank test, and we compared the score among images obtained at 50 to 90 keV with use of MCA using Kruskal-Wallis and post hoc tests. We also compared the percentages of image interpretability and improvement in image interpretability among images obtained at 50 to 90 keV with use of MCA. Results: With the use of MCA, the average score of CMA was significantly higher for images obtained at each energy level from 50 to 70 keV (P < 0.05) and was comparable at 80 and 90 keV, and it was comparable among those obtained at 50 to 70 keV. With its use, the percentages of image interpretability were similarly high at 50 to 70 keV at 60 to 80 beats per minute (78%–100%), and they were higher at 50 to 60 keV (72%–83%) than at 70 keV at 90 to 100 beats per minute (50%–56%). The percentages of improved image interpretability with MCA were similarly high at 50 to 70 keV at 60 to 80 beats per minute (56%–100%), and they were higher at 50 to 60 keV (62%–77%) than at 70 keV at 90 to 100 beats per minute (36%–43%). The percentages of image interpretability and improved image interpretability with MCA were insufficient at 80 and 90 keV. Conclusions: Coronary motion artifacts were significantly reduced in images of monochromatic CCTA obtained at 50 to 70 keV in combination with MCA compared with those obtained without MCA, and the percentages of image interpretability and improved image interpretability with use of MCA were relatively high at 50 to 70 keV, and particularly at 50 to 60 keV, even at 90 to 100 beats per minute.
- 1 August 2016
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 51 (8) , 513-519
Reduction of Coronary Motion Artifacts in Prospectively Electrocardiography-Gated Coronary Computed Tomography Angiography Using Monochromatic Imaging at Various Energy Levels in Combination With a Motion Correction Algorithm on Single-Source Fast Tube Voltage Switching Dual-Energy Computed Tomography
Objectives: The aim of this study was to assess the effect of monochromatic imaging at various energy levels in combination with a motion correction algorithm (MCA) in single-source dual-energy coronary computed tomography angiography (CCTA) with fast switching of tube voltage on the reduction of coronary motion artifacts (CMA) in a phantom setting. Materials and Methods: Using this dual-energy computed tomography technique with a phantom comprising models of coronary vessels filled with contrast medium and pulsating at constant heart rates of 60 to 100 beats per minute, we reconstructed monochromatic images of CCTA obtained at 50 to 90 keV with and without use of MCA. Cardiac motion was modeled by simulating the in vivo time-volume curve of the left ventricle. Two independent readers graded CMA in 9 coronary segments using a 5-point scale (1, poor; 3 to 5, interpretable; 5, excellent). At each heart rate, we compared the average score of CMA between images obtained at 50 to 90 keV with and without use of MCA using Wilcoxon signed rank test, and we compared the score among images obtained at 50 to 90 keV with use of MCA using Kruskal-Wallis and post hoc tests. We also compared the percentages of image interpretability and improvement in image interpretability among images obtained at 50 to 90 keV with use of MCA. Results: With the use of MCA, the average score of CMA was significantly higher for images obtained at each energy level from 50 to 70 keV (P < 0.05) and was comparable at 80 and 90 keV, and it was comparable among those obtained at 50 to 70 keV. With its use, the percentages of image interpretability were similarly high at 50 to 70 keV at 60 to 80 beats per minute (78%–100%), and they were higher at 50 to 60 keV (72%–83%) than at 70 keV at 90 to 100 beats per minute (50%–56%). The percentages of improved image interpretability with MCA were similarly high at 50 to 70 keV at 60 to 80 beats per minute (56%–100%), and they were higher at 50 to 60 keV (62%–77%) than at 70 keV at 90 to 100 beats per minute (36%–43%). The percentages of image interpretability and improved image interpretability with MCA were insufficient at 80 and 90 keV. Conclusions: Coronary motion artifacts were significantly reduced in images of monochromatic CCTA obtained at 50 to 70 keV in combination with MCA compared with those obtained without MCA, and the percentages of image interpretability and improved image interpretability with use of MCA were relatively high at 50 to 70 keV, and particularly at 50 to 60 keV, even at 90 to 100 beats per minute.
- 1 July 2016
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 36 (4) , 1215-1232
Dual-Energy Spectral CT: Various Clinical Vascular Applications
The value of CT for vascular applications is enhanced by an understanding of the limitations of standard single-energy CT angiography and knowledge of various techniques of single-source dual-energy CT with fast switching of tube voltage, including acquisition of monochromatic and material decomposition images and use of the spectral Hounsfield unit curve and histograms of effective atomic numbers, and their clinical applications to overcome these limitations. Single-source dual-energy (DE) computed tomography (CT) with fast switching of tube voltage allows projection-based image reconstruction, substantial reduction of beam-hardening effects, reconstruction of accurate monochromatic images and material decomposition images (MDIs), and detailing of material composition by using x-ray spectral information. In vascular applications, DE CT is expected to overcome limitations of standard single-energy CT angiography, including patient exposure to nephrotoxic contrast medium and carcinogenic radiation, insufficient contrast vascular enhancement, interference from metallic and beam-hardening artifacts and severe vessel calcification, and limited tissue characterization and perfusion assessment. Acquisition of low-energy monochromatic images and iodine/water MDIs can reasonably reduce contrast agent dose and improve vessel enhancement. Acquisition of virtual noncontrast images, such as water/iodine MDIs, can reduce overall radiation exposure by replacing true noncontr...
- 1 July 2016
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 36 (4) , 1215-1232
Dual-Energy Spectral CT: Various Clinical Vascular Applications
The value of CT for vascular applications is enhanced by an understanding of the limitations of standard single-energy CT angiography and knowledge of various techniques of single-source dual-energy CT with fast switching of tube voltage, including acquisition of monochromatic and material decomposition images and use of the spectral Hounsfield unit curve and histograms of effective atomic numbers, and their clinical applications to overcome these limitations. Single-source dual-energy (DE) computed tomography (CT) with fast switching of tube voltage allows projection-based image reconstruction, substantial reduction of beam-hardening effects, reconstruction of accurate monochromatic images and material decomposition images (MDIs), and detailing of material composition by using x-ray spectral information. In vascular applications, DE CT is expected to overcome limitations of standard single-energy CT angiography, including patient exposure to nephrotoxic contrast medium and carcinogenic radiation, insufficient contrast vascular enhancement, interference from metallic and beam-hardening artifacts and severe vessel calcification, and limited tissue characterization and perfusion assessment. Acquisition of low-energy monochromatic images and iodine/water MDIs can reasonably reduce contrast agent dose and improve vessel enhancement. Acquisition of virtual noncontrast images, such as water/iodine MDIs, can reduce overall radiation exposure by replacing true noncontr...
- 1 May 2016
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 36 (3) , 735-750
Whole-Body Clinical Applications of Digital Tomosynthesis
To achieve optimal patient management, radiologists and radiologic technologists benefit from understanding the clinical utilities and limitations of whole-body applications of digital tomosynthesis, which can (a) reduce tissue overlap and improve depth resolution compared with conventional mammography, radiography, and fluoroscopy and (b) reduce radiation exposure and metallic artifacts and improve in-plane resolution and patient positioning flexibility compared with CT. With flat-panel detector mammography, radiography, and fluoroscopy systems, digital tomosynthesis (DT) has been recently introduced as an advanced clinical application that removes overlying structures, enhances local tissue separation, and provides depth information about structures of interest by providing high-quality tomographic images. DT images are generated from projection image data, typically using filtered back-projection or iterative reconstruction. These low-dose x-ray projection images are easily and swiftly acquired over a range of angles during a single linear or arc sweep of the x-ray tube assembly. DT is advantageous in a variety of clinical contexts, including breast, chest, head and neck, orthopedic, emergency, and abdominal imaging. Specifically, compared with conventional mammography, radiography, and fluoroscopy, as a result of reduced tissue overlap DT can improve detection of breast cancer, pulmonary nodules, sinonasal mucosal thickening, and bone fractures and delineation of compl...
- 1 May 2016
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 36 (3) , 735-750
Whole-Body Clinical Applications of Digital Tomosynthesis
To achieve optimal patient management, radiologists and radiologic technologists benefit from understanding the clinical utilities and limitations of whole-body applications of digital tomosynthesis, which can (a) reduce tissue overlap and improve depth resolution compared with conventional mammography, radiography, and fluoroscopy and (b) reduce radiation exposure and metallic artifacts and improve in-plane resolution and patient positioning flexibility compared with CT. With flat-panel detector mammography, radiography, and fluoroscopy systems, digital tomosynthesis (DT) has been recently introduced as an advanced clinical application that removes overlying structures, enhances local tissue separation, and provides depth information about structures of interest by providing high-quality tomographic images. DT images are generated from projection image data, typically using filtered back-projection or iterative reconstruction. These low-dose x-ray projection images are easily and swiftly acquired over a range of angles during a single linear or arc sweep of the x-ray tube assembly. DT is advantageous in a variety of clinical contexts, including breast, chest, head and neck, orthopedic, emergency, and abdominal imaging. Specifically, compared with conventional mammography, radiography, and fluoroscopy, as a result of reduced tissue overlap DT can improve detection of breast cancer, pulmonary nodules, sinonasal mucosal thickening, and bone fractures and delineation of compl...
- 12 December 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (2) , 84-93
Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate
We retrospectively investigated the effect of the motion correction algorithm (MCA) on image quality and interpretability by heart rate (HR) in coronary CT angiography (CCTA). For 105 patients (6 HR groups) undergoing CCTA, 2 readers independently graded the image quality of the 4 major coronary arteries reconstructed with and without MCA at diastole with HR ≤64 bpm and at systole and diastole ≥65 bpm using a 5-point scale. For each HR group and cardiac phase, we compared per-vessel and per-segment image quality using Wilcoxon signed rank test and percentages of interpretable image quality (scores 3–5) among without MCA at diastole with HR ≤64 bpm, as a reference, with MCA at diastole ≤69 bpm and at systole 70–79 bpm using the chi-square test. The motion correction algorithm reconstruction provided similar or better image quality and interpretability in all groups, with 96–100 % per-vessel (P = 0.008 for the right coronary artery; otherwise, P > 0.05) and 99 % per-segment interpretable image quality (P = 0.0002) at diastole with HR ≤69 bpm and at systole 70–79 bpm compared to the reference (88–100 and 97 %, respectively). MCA reconstruction preserved image quality and interpretability of CCTA with HR ≤79 bpm.
- 12 December 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (2) , 84-93
Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate
We retrospectively investigated the effect of the motion correction algorithm (MCA) on image quality and interpretability by heart rate (HR) in coronary CT angiography (CCTA). For 105 patients (6 HR groups) undergoing CCTA, 2 readers independently graded the image quality of the 4 major coronary arteries reconstructed with and without MCA at diastole with HR ≤64 bpm and at systole and diastole ≥65 bpm using a 5-point scale. For each HR group and cardiac phase, we compared per-vessel and per-segment image quality using Wilcoxon signed rank test and percentages of interpretable image quality (scores 3–5) among without MCA at diastole with HR ≤64 bpm, as a reference, with MCA at diastole ≤69 bpm and at systole 70–79 bpm using the chi-square test. The motion correction algorithm reconstruction provided similar or better image quality and interpretability in all groups, with 96–100 % per-vessel (P = 0.008 for the right coronary artery; otherwise, P > 0.05) and 99 % per-segment interpretable image quality (P = 0.0002) at diastole with HR ≤69 bpm and at systole 70–79 bpm compared to the reference (88–100 and 97 %, respectively). MCA reconstruction preserved image quality and interpretability of CCTA with HR ≤79 bpm.
- 4 February 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (4) , 217-223
A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments
To investigate a method for selecting a protocol for body CT scan to acquire monochromatic images (MIs) by gemstone spectral imaging (GSI) with or without adaptive statistical iterative reconstruction (ASiR). We subjected a phantom to conventional scanning at 120 kVp and 50–700 mAs and GSI at 165–600 mAs; reconstructed MIs at 65 keV with ASiR 0–100 % for GSI; placed 5 regions of interest on each of 3 consecutive reconstructed slices to obtain the averaged standard deviation (SD) as image noise for conventional scan and GSI. Linear regression analysis yielded the mAs by conventional scan that could be used to achieve similar image noise by GSI. To achieve similar noise, we found excellent linear correlation of mAs between GSI with ASiR 0–100 % and conventional scan (r = 1.00, P We can select a protocol for body CT scan for MIs at 65 keV with or without ASiR with results comparable to those of conventional CT at 120 kVp.
- 4 February 2014
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (4) , 217-223
A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments
To investigate a method for selecting a protocol for body CT scan to acquire monochromatic images (MIs) by gemstone spectral imaging (GSI) with or without adaptive statistical iterative reconstruction (ASiR). We subjected a phantom to conventional scanning at 120 kVp and 50–700 mAs and GSI at 165–600 mAs; reconstructed MIs at 65 keV with ASiR 0–100 % for GSI; placed 5 regions of interest on each of 3 consecutive reconstructed slices to obtain the averaged standard deviation (SD) as image noise for conventional scan and GSI. Linear regression analysis yielded the mAs by conventional scan that could be used to achieve similar image noise by GSI. To achieve similar noise, we found excellent linear correlation of mAs between GSI with ASiR 0–100 % and conventional scan (r = 1.00, P We can select a protocol for body CT scan for MIs at 65 keV with or without ASiR with results comparable to those of conventional CT at 120 kVp.
- 7 June 2013
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 31 (7) , 465-470
Dual-energy subtraction radiography improves laryngeal delineation in patients with moderate to severe cervical spondylosis
- 7 June 2013
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 31 (7) , 465-470
Dual-energy subtraction radiography improves laryngeal delineation in patients with moderate to severe cervical spondylosis
- 1 February 2013
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 200 (2) , 442-446
Improved Delineation of the Anterior Spinal Artery With Model-Based Iterative Reconstruction in CT Angiography: A Clinical Pilot Study
OBJECTIVE. The purpose of this study was to investigate the utility of model-based iterative reconstruction (MBIR) for improving delineation of the anterior spinal artery (ASA) during routine-dose CT angiography. MATERIALS AND METHODS. For imaging of 10 patients (six men, four women; mean age, 73.9 ± 7.5 years) consecutively undergoing CT angiography of the whole aorta with a 12-HU noise index, we used filtered back projection with a standard kernel, adaptive statistical iterative reconstruction of 40% with a detail kernel, and MBIR to reconstruct axial and oblique coronal multiplanar reformation images to delineate the ASA. We measured objective noise in the spinal cord and contrast-to-noise ratio (CNR) between the aorta and spinal cord on axial images at the T12 level. Two radiologists independently graded subjective noise and ASA delineation on the multiplanar reformation images from 1 (poor) to 4 (excellent). We compared results among the three reconstructions using one-way analysis of variance and Tu...
- 1 February 2013
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 200 (2) , 442-446
Improved Delineation of the Anterior Spinal Artery With Model-Based Iterative Reconstruction in CT Angiography: A Clinical Pilot Study
OBJECTIVE. The purpose of this study was to investigate the utility of model-based iterative reconstruction (MBIR) for improving delineation of the anterior spinal artery (ASA) during routine-dose CT angiography. MATERIALS AND METHODS. For imaging of 10 patients (six men, four women; mean age, 73.9 ± 7.5 years) consecutively undergoing CT angiography of the whole aorta with a 12-HU noise index, we used filtered back projection with a standard kernel, adaptive statistical iterative reconstruction of 40% with a detail kernel, and MBIR to reconstruct axial and oblique coronal multiplanar reformation images to delineate the ASA. We measured objective noise in the spinal cord and contrast-to-noise ratio (CNR) between the aorta and spinal cord on axial images at the T12 level. Two radiologists independently graded subjective noise and ASA delineation on the multiplanar reformation images from 1 (poor) to 4 (excellent). We compared results among the three reconstructions using one-way analysis of variance and Tu...
- Open Access
- 4 January 2013
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 34 (5) , 971-975
Improved Delineation of Arteries in the Posterior Fossa of the Brain by Model-Based Iterative Reconstruction in Volume-Rendered 3D CT Angiography
BACKGROUND AND PURPOSE: Improved CTA delineation of arteries and unruptured aneurysms is clinically desired in the posterior fossa. We present a novel model-based iterative reconstruction that models system statistics and optics to improve CT image quality. We investigated the utility of MBIR for improving delineation of arteries in the posterior fossa on 3D brain CTA. MATERIALS AND METHODS: Using filtered back-projection with a standard kernel and MBIR, we reconstructed axial images of 0.625-mm thickness of 28 consecutive patients (14 men; mean age, 58.6 ± 14.6 years) who underwent 64-detector brain CTA. We placed regions of interest on the axial images, measured the mean CT value in the basilar artery and the value and SD in the pons and bilateral cerebellar hemispheres, and calculated the contrast-to-noise ratio of the brain arteries in the posterior fossa. Using volume-rendered CTA and a 4-point scale, 2 radiologists independently graded delineation of the BA, bilateral vertebral artery, superior cerebellar artery, and anterior and posterior inferior cerebellar arteries. We compared the results between FBP and MBIR by using paired t and Wilcoxon signed-rank tests. RESULTS: Compared with FBP, MBIR significantly improved the contrast-to-noise ratio (P < .0001) and subjective delineation of all arteries in the posterior fossa except the BA (VA, SCA, AICA, and PICA; P < .05 for all). The mean visual score by MBIR was 3.0 or higher for all those arteries except the AICA assessed by reader 1 (2.6 ± 0.7). CONCLUSIONS: With 3D brain CTA, contrast-to-noise ratio and arterial delineation of the VA, SCA, AICA, and PICA in the posterior fossa are better with MBIR than FBP.
- 4 January 2013
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 34 (5) , 971-975
Open AccessImproved Delineation of Arteries in the Posterior Fossa of the Brain by Model-Based Iterative Reconstruction in Volume-Rendered 3D CT Angiography
BACKGROUND AND PURPOSE: Improved CTA delineation of arteries and unruptured aneurysms is clinically desired in the posterior fossa. We present a novel model-based iterative reconstruction that models system statistics and optics to improve CT image quality. We investigated the utility of MBIR for improving delineation of arteries in the posterior fossa on 3D brain CTA. MATERIALS AND METHODS: Using filtered back-projection with a standard kernel and MBIR, we reconstructed axial images of 0.625-mm thickness of 28 consecutive patients (14 men; mean age, 58.6 ± 14.6 years) who underwent 64-detector brain CTA. We placed regions of interest on the axial images, measured the mean CT value in the basilar artery and the value and SD in the pons and bilateral cerebellar hemispheres, and calculated the contrast-to-noise ratio of the brain arteries in the posterior fossa. Using volume-rendered CTA and a 4-point scale, 2 radiologists independently graded delineation of the BA, bilateral vertebral artery, superior cerebellar artery, and anterior and posterior inferior cerebellar arteries. We compared the results between FBP and MBIR by using paired t and Wilcoxon signed-rank tests. RESULTS: Compared with FBP, MBIR significantly improved the contrast-to-noise ratio (P < .0001) and subjective delineation of all arteries in the posterior fossa except the BA (VA, SCA, AICA, and PICA; P < .05 for all). The mean visual score by MBIR was 3.0 or higher for all those arteries except the AICA assessed by reader 1 (2.6 ± 0.7). CONCLUSIONS: With 3D brain CTA, contrast-to-noise ratio and arterial delineation of the VA, SCA, AICA, and PICA in the posterior fossa are better with MBIR than FBP.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (2) , 252-256
Detection of Paranasal Sinus Opacification With Digital Tomosynthesis Radiography
Objective We investigated the diagnostic accuracy of digital tomosynthesis (DT) radiography for detecting sinus opacification. Methods For 31 adult patients with signs suggestive of sinusitis who underwent both sinus multi–detector-row computed tomography and DT, 2 readers independently assessed opacification in the maxillary, ethmoid, frontal, and sphenoid sinuses by DT and in consensus determined the presence of opacification in each sinus by multi–detector-row computed tomography as a reference. We assessed the diagnostic accuracy of DT and interreader agreement with DT using Cohen κ statistics. Results For the maxillary, ethmoid, frontal, and sphenoid sinuses, opacification was identified in 81.7%, 75.9%, 59.3%, and 40.7%; the sensitivity/specificity for detecting opacification by DT were 93.9/72.7%, 79.5/71.4%, 93.8/72.7%, and 90.9/75.0% for reader 1 and 95.9/100.0%, 95.5/92.9%, 100.0/81.8%, and 81.8/75.0% for reader 2; the interreader agreement was 0.79, 0.42, 0.67, and 0.63, respectively. Conclusions Digital tomosynthesis allows relatively accurate detection of sinus opacification with substantial interreader agreement for all the sinuses except the ethmoid sinuses.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (2) , 252-256
Detection of Paranasal Sinus Opacification With Digital Tomosynthesis Radiography
Objective We investigated the diagnostic accuracy of digital tomosynthesis (DT) radiography for detecting sinus opacification. Methods For 31 adult patients with signs suggestive of sinusitis who underwent both sinus multi–detector-row computed tomography and DT, 2 readers independently assessed opacification in the maxillary, ethmoid, frontal, and sphenoid sinuses by DT and in consensus determined the presence of opacification in each sinus by multi–detector-row computed tomography as a reference. We assessed the diagnostic accuracy of DT and interreader agreement with DT using Cohen κ statistics. Results For the maxillary, ethmoid, frontal, and sphenoid sinuses, opacification was identified in 81.7%, 75.9%, 59.3%, and 40.7%; the sensitivity/specificity for detecting opacification by DT were 93.9/72.7%, 79.5/71.4%, 93.8/72.7%, and 90.9/75.0% for reader 1 and 95.9/100.0%, 95.5/92.9%, 100.0/81.8%, and 81.8/75.0% for reader 2; the interreader agreement was 0.79, 0.42, 0.67, and 0.63, respectively. Conclusions Digital tomosynthesis allows relatively accurate detection of sinus opacification with substantial interreader agreement for all the sinuses except the ethmoid sinuses.