Characterization of bioparticles using a miniature cylindrical ion trap mass spectrometer operated at rough vacuum
- 1 January 2011
- journal article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 136 (7) , 1305-1309
Abstract
A miniature cylindrical ion trap mass spectrometer (CIT-MS) equipped with an inexpensive mechanical pump was constructed, and used to measure the masses of cells and microparticles generated by laser induced acoustic desorption ionization. Compared with a previous lab scale quadrupole ion trap mass spectrometer (QIT-MS), the novel miniature CIT-MS had smaller volume (the radius r0 = 5 mm), simpler ion trap fabrication and overall instrument construction, required a lower trapping voltage, and reduced the weight, power and cost of the instrument. The CIT-MS was calibrated using standard polystyrene beads of 2.982 µm diameter. The CIT-MS was used to measure the total dry weight of human red blood cells (RBCs) from a healthy female adult (2.12 × 1013 Da) and a patient with anemia (1.35 × 1013 Da). The coefficient of variance (CV) for the healthy individual was 21% and that for the patient was 30.4%. The CIT-MS was also applied to guinea pig RBCs and the total dry weight was determined as 1.34 × 1013 Da with a CV of 37.9%. These measurements are consistent with previous QIT-MS measurements. The new miniaturized instrument has potential for applications in field-portable, biological and aerosol analysis.Keywords
This publication has 42 references indexed in Scilit:
- Ultrahigh-Mass Mass Spectrometry of Single Biomolecules and BioparticlesAnnual Review of Analytical Chemistry, 2009
- Weighing of biomolecules, single cells and single nanoparticles in fluidNature, 2007
- Analysis of Megadalton Ions Using Cryodetection MALDI Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2005
- Single virus particle mass detection using microresonators with nanoscale thicknessApplied Physics Letters, 2004
- Single cell detection with micromechanical oscillatorsJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 2001
- Mass Spectrometry of an Intact VirusAngewandte Chemie International Edition, 2001
- Electrospray Time-of-Flight Mass Spectrometry of the Intact MS2 Virus CapsidJournal of the American Chemical Society, 2000
- Detection of High Molecular Weight Narrow Polydisperse Polymers up to 1.5 Million Daltons by MALDI Mass SpectrometryAnalytical Chemistry, 1996
- Molecular weight determination of megadalton DNA electrospray ions using charge detection time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1995
- Electrospray mass spectrometry of poly(ethylene glycols) with molecular weights up to five millionJournal of the American Chemical Society, 1992